TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

DIRECTIONAL DETECTOR [3 records]

Record 1 2010-12-22

English

Subject field(s)
  • Flight Instruments and Equipment (Aeroindustry)
  • Navigation Instruments
DEF

gyromagnetic compass : A directional gyroscope whose azimuth scales is maintained in alignment with the magnetic meridian by a magnetic detector unit.

CONT

The gyrosyn compass combines the functions of both the directional gyro and the magnetic compass. It provides stable compass headings in rough air, is north seeking like a magnetic compass, but is free from northerly turning error and oscillation. It does not precess and, therefore, does not require resetting as does the directional gyro. The gyrosyn compass system incorporates a flux valve that senses the earth’s magnetic lines of force through electromagnetic induction.

OBS

Gyrosyn: A registered name for gyrosynchronized compass comprising direction indicator (DI) slaved to magnetic meridian by fluxgate.

OBS

gyromagnetic compass: term and definition standardized by NATO.

French

Domaine(s)
  • Instruments et équipement de bord (Constructions aéronautiques)
  • Instruments de navigation
DEF

compas gyromagnétique : Gyroscope directionnel dont l'échelle d'azimut est asservie à la direction du nord magnétique par un dispositif de détection magnétique.

CONT

Le compas gyromagnétique ou gyrosyn. [...] le conservateur de cap ou compas gyroscopique est un instrument stable mais qui ne fournit pas d'indication de cap magnétique. Son recalage en azimut doit se faire manuellement. Inversement, la vanne de flux fournit une indication précise de cap mais est instable. En associant ces deux instruments, on obtient un compas gyromagnétique qui fournit une indication de cap tout en étant stable. [...] Les compas gyromagnétiques se composent d'un conservateur de cap avec un système d'érection en site, d'un élément détecteur de la composante horizontale du champ magnétique terrestre, d'un système détecteur d'erreur qui compare en permanence le cap gyro et le cap magnétique.

OBS

compas gyromagnétique : terme et définition normalisés par l'OTAN.

OBS

compas gyrosyn : terme uniformisé par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Opérations aériennes.

Spanish

Campo(s) temático(s)
  • Instrumentos y equipo de vuelo (Industria aeronáutica)
  • Instrumentos de navegación
DEF

Giróscopo direccional cuya escala de acimut se mantiene en la dirección del norte magnético gracias a un dispositivo de detección magnética.

Save record 1

Record 2 - external organization data 1994-11-03

English

Subject field(s)
  • Scientific Instruments
  • Measuring Instruments (Engineering)
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
CONT

The meter to be calibrated shall :(1) be positioned on the jig to minimize geotropism, directional dependence, and non-uniformity of the calibration radiation beam across and through the detector volume....

French

Domaine(s)
  • Instruments scientifiques
  • Instruments de mesure (Ingénierie)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le gammamètre à étalonner doit : a) être placé sur le tréteau de manière à minimiser le géotropisme, la dépendance directionnelle et le manque d'uniformité du faisceau de rayonnement d'étalonnage à travers le volume du détecteur [...]

Spanish

Save record 2

Record 3 - external organization data 1994-10-27

English

Subject field(s)
  • Metrology and Units of Measure
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
DEF

... a change in instrument response with respect to orientation of the instrument for constant exposure rate, excluding geotropism.

CONT

The meter to be calibrated shall :(1) be positioned on the jig to minimize geotropism, directional dependence, and non-uniformity of the calibration radiation beam across and through the detector volume....

French

Domaine(s)
  • Unités de mesure et métrologie
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Modification de la réponse de l'appareil selon son orientation par rapport au débit d'exposition constant, non compris le géotropisme.

CONT

Le gammamètre à étalonner doit : a) être placé sur le tréteau de manière à minimiser le géotropisme, la dépendance directionnelle et le manque d'uniformité du faisceau de rayonnement d'étalonnage à travers le volume du détecteur [...]

Spanish

Save record 3

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2024
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: