TERMIUM Plus®
The Government of Canada’s terminology and linguistic data bank.
AMPLITUDE FILTERING [4 records]
Record 1 - internal organization data 2021-02-02
Record 1, English
Record 1, Subject field(s)
- Amplifiers (Electronics)
Record 1, Main entry term, English
- lock-in amplifier
1, record 1, English, lock%2Din%20amplifier
correct
Record 1, Abbreviations, English
Record 1, Synonyms, English
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
Lock-in amplifiers were invented in the 1930's and commercialized in the mid 20th century as electrical instruments capable of extracting signal amplitudes and phases in extremely noisy environments... They employ a homodyne detection scheme and low-pass filtering to measure a signal' s amplitude and phase relative to a periodic reference. 2, record 1, English, - lock%2Din%20amplifier
Record 1, French
Record 1, Domaine(s)
- Amplificateurs (Électronique)
Record 1, Main entry term, French
- amplificateur à détection synchrone
1, record 1, French, amplificateur%20%C3%A0%20d%C3%A9tection%20synchrone
correct, masculine noun
Record 1, Abbreviations, French
Record 1, Synonyms, French
- amplificateur synchrone 2, record 1, French, amplificateur%20synchrone
correct, masculine noun
Record 1, Textual support, French
Record 1, Spanish
Record 1, Textual support, Spanish
Record 2 - internal organization data 2009-04-30
Record 2, English
Record 2, Subject field(s)
- Audio Technology
Record 2, Main entry term, English
- noise suppression filter 1, record 2, English, noise%20suppression%20filter
Record 2, Abbreviations, English
Record 2, Synonyms, English
- noise suppressor filter 2, record 2, English, noise%20suppressor%20filter
Record 2, Textual support, English
Record number: 2, Textual support number: 1 CONT
Noise Suppression Filter. The patent describes a simple and inexpensive device for filtering undesirable high frequency noise from analog data outputs of a data processing system, which operates in two different modes and switches automatically from one to the other depending on the rate of change of data functions and on data transient amplitude with respect to full scale. 1, record 2, English, - noise%20suppression%20filter
Record 2, French
Record 2, Domaine(s)
- Électroacoustique
Record 2, Main entry term, French
- filtre antiparasites
1, record 2, French, filtre%20antiparasites
masculine noun
Record 2, Abbreviations, French
Record 2, Synonyms, French
Record 2, Textual support, French
Record number: 2, Textual support number: 1 CONT
L'invention concerne un filtre antiparasites à particules permettant de supprimer du bruit non souhaité par augmentation de la résistance spécifique de la ferrite MnZn et l'amélioration d'une caractéristique haute fréquence. 1, record 2, French, - filtre%20antiparasites
Record 2, Spanish
Record 2, Textual support, Spanish
Record 3 - internal organization data 2000-06-02
Record 3, English
Record 3, Subject field(s)
- Amplifiers (Electronics)
- Electronic Measurements
- Thermoelectricity and Thermoelectronics
- Burners and Steamfitting
Record 3, Main entry term, English
- flame signal amplifier
1, record 3, English, flame%20signal%20amplifier
correct
Record 3, Abbreviations, English
Record 3, Synonyms, English
Record 3, Textual support, English
Record number: 3, Textual support number: 1 DEF
The part of the flame detection system which increases the flame signal to a magnitude sufficient to pull in the flame relay in the flame safeguard control. The amplifier may be a permanent part of the flame safeguard control, or it may be a replaceable, plug-in unit. 2, record 3, English, - flame%20signal%20amplifier
Record number: 3, Textual support number: 1 CONT
Hegwein pilot burners are compact, sturdy, and feature a modular design. Models are available with a built-in ignition transformer, or with both flame signal amplifier and ignition transformer. 3, record 3, English, - flame%20signal%20amplifier
Record number: 3, Textual support number: 1 OBS
Flame signal: the current measured at the meter jack of a flame signal amplifier in a flame safeguard control. The current is produced by the flame detector when it senses a flame. 2, record 3, English, - flame%20signal%20amplifier
Record number: 3, Textual support number: 2 OBS
Conventional multi-burner scanners have relied on the strength or amplitude of the flame signal to discriminate between burner flame-on and burner flame-off. This is most often done by using the amplitude output of the flame signal after bandpass or highpass filtering. 4, record 3, English, - flame%20signal%20amplifier
Record 3, French
Record 3, Domaine(s)
- Amplificateurs (Électronique)
- Mesures électroniques
- Thermoélectrique et thermoélectronique
- Fumisterie et brûleurs
Record 3, Main entry term, French
- amplificateur du signal de flamme
1, record 3, French, amplificateur%20du%20signal%20de%20flamme
proposal, masculine noun
Record 3, Abbreviations, French
Record 3, Synonyms, French
- amplificateur du signal électrique de la flamme 1, record 3, French, amplificateur%20du%20signal%20%C3%A9lectrique%20de%20la%20flamme
proposal, masculine noun
Record 3, Textual support, French
Record 3, Spanish
Record 3, Textual support, Spanish
Record 4 - internal organization data 2000-03-31
Record 4, English
Record 4, Subject field(s)
- Electronic Measurements
- Thermoelectricity and Thermoelectronics
- Burners and Steamfitting
Record 4, Main entry term, English
- flame signal
1, record 4, English, flame%20signal
correct
Record 4, Abbreviations, English
Record 4, Synonyms, English
Record 4, Textual support, English
Record number: 4, Textual support number: 1 DEF
The current measured at the meter jack of a flame signal amplifier in a flame safeguard control. The current is produced by the flame detector when it senses a flame. 2, record 4, English, - flame%20signal
Record number: 4, Textual support number: 1 CONT
The Keyboard Status Display Module [Honeywell burner control] instantly identifies complete information for servicing including interlock, limit and fuel circuit status. It also enables you to check terminal voltage status and read flame signal strength in dc volts, eliminating the need to use a meter. 3, record 4, English, - flame%20signal
Record number: 4, Textual support number: 1 OBS
Conventional multi-burner scanners have relied on the strength or amplitude of the flame signal to discriminate between burner flame-on and burner flame-off. This is most often done by using the amplitude output of the flame signal after bandpass or highpass filtering. 4, record 4, English, - flame%20signal
Record 4, French
Record 4, Domaine(s)
- Mesures électroniques
- Thermoélectrique et thermoélectronique
- Fumisterie et brûleurs
Record 4, Main entry term, French
- signal émis par la flamme
1, record 4, French, signal%20%C3%A9mis%20par%20la%20flamme
proposal, masculine noun
Record 4, Abbreviations, French
Record 4, Synonyms, French
- signal électrique émis par la flamme 1, record 4, French, signal%20%C3%A9lectrique%20%C3%A9mis%20par%20la%20flamme
proposal, masculine noun
Record 4, Textual support, French
Record 4, Spanish
Record 4, Textual support, Spanish
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2024
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada
Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools
The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies
Access Translation Bureau glossaries and vocabularies.
- Date Modified: