TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

TURN-ON TIME [3 fiches]

Fiche 1 - données d’organisme externe 2002-02-27

Anglais

Subject field(s)
  • Electrical Engineering
  • Explosives and Pyrotechnical Materials (Industries)
  • Compartment - Canadian Nuclear Safety Commission
CONT

Electronic components for firing sets (switching devices and pulse discharge capacitors): (a) switching devices: (1) cold-cathode tubes ... (2) triggered spark-gaps ... and (3) modules or assemblies with a fast switching function having all of the following characteristics: (i) anode peak voltage rating greater than 2 000 V; (ii) anode peak current rating of 500 A or more; and (iii) turn-on time of 1 s or less ...

OBS

Regulation cited: Nuclear Non-Proliferation Import and Export Control Regulations.

Français

Domaine(s)
  • Électrotechnique
  • Explosifs et artifices (Industries)
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Composants électroniques pour les appareils de mise à feu (dispositifs de commutation et condensateurs à décharge d'impulsions) : a) dispositifs de commutation : (1) tubes à cathode froide [...] (2) éclateurs à étincelle [...] (3) modules ou assemblages à commutation rapide possédant toutes les caractéristiques suivantes : (i) tension anodique nominale de pointe supérieure à 2 000 V; (ii) courant de plaque nominal de pointe égal ou supérieur à 500 A; (iii) temps de commutation égal ou inférieur à 1 s [...]

OBS

Règlement cité : Règlement sur le contrôle de l'importation et de l'exportation aux fins de la non-prolifération nucléaire.

Espagnol

Conserver la fiche 1

Fiche 2 2001-08-21

Anglais

Subject field(s)
  • Electrical Power Supply
DEF

The time from the initial application of power until a sensor produces a specified useful output, though not necessarily at the accuracy of full specification performance.

CONT

External Remote Control: Inputs per channel with common ground. Connection of ground to a remote input switches the amplifier input from the line source to the mic source. The mic turn-on time is immediate with 1.5 second line level turn-on time after manual gating.

CONT

Advanced dynamic detectors ... Specifications ... Electrical ... Turn-on time: typ. 60s from power-on.

Français

Domaine(s)
  • Alimentation (Distribution électrique)
DEF

Après sa mise sous tension, temps nécessaire à un appareil électrique pour en arriver à un rendement minimal.

Espagnol

Conserver la fiche 2

Fiche 3 2001-02-02

Anglais

Subject field(s)
  • Printed Circuits and Microelectronics
  • Electronic Circuits Technology
DEF

The time required for an output to turn on (sink current, to ground output, to go to 0 volt). It is the propagation time of an appropriate input signal to cause the output to go to 0 volt.

Français

Domaine(s)
  • Circuits imprimés et micro-électronique
  • Technologie des circuits électroniques

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2024
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :