TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

PILOT FLAME [25 fiches]

Fiche 1 2016-05-04

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
DEF

A liquid-fuel burner ... using a mixture of air and vaporized or atomized oil for combustion.

CONT

An oil burner is defined by the National Oil Fuel Institute as a mechanical device for preparing fuel oil to combine with air under controlled conditions for combustion. Two methods(atomization and vaporization) are used for the preparation of fuel oil for the combustion process. Air for combustion is supplied by natural or mechanical draft. Ignition is generally accomplished by an electric spark, gas pilot flame, or oil pilot flame. Burners of different types operate with luminous or nonluminous flame. Operation may be continuous, intermittent, modulating, or high-low flame.

OBS

oil burner: term officially approved by the Lexicon Project Committee (New Brunswick).

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

Un brûleur à mazout a deux tâches essentielles à remplir : [transformer] le mazout [...] en vapeur ou en fines particules; assurer la distribution de tout ou partie de l'air nécessaire à la combustion. La transformation du mazout en fines particules peut s'opérer suivant plusieurs méthodes : brûleur à gazéification [...] brûleur à pulvérisation par air [...]

OBS

fioul : Cette graphie, puisée des Rectifications de l'orthographe recommandées par le Conseil supérieur de la langue française, est attestée dans le Petit Robert (2004).

OBS

brûleur à fuel : Ce terme est à éviter, car le mot «fuel» est un anglicisme pour «mazout».

OBS

brûleur à mazout : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Espagnol

Conserver la fiche 1

Fiche 2 2011-06-10

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

... a flame, smaller than the main burner flame, ... used to light off the main burner or burners.

OBS

pilot; pilot flame : terms officially approved by the Lexicon Project Committee(New Brunswick).

Français

Domaine(s)
  • Fumisterie et brûleurs
DEF

Petite flamme d'un appareil à gaz ou à mazout que l'on peut laisser brûler en permanence pour permettre l'allumage automatique de l'appareil.

CONT

[...] le brûleur à flamme pilote : celle-ci, alimentée par une fine cannelure, se trouve à la base de la flamme principale, qu'elle stabilise.

OBS

veilleuse; flamme pilote : termes uniformisés par le Comité du projet de lexiques (Nouveau-Brunswick).

Espagnol

Conserver la fiche 2

Fiche 3 2010-02-25

Anglais

Subject field(s)
  • Plumbing
CONT

What should the normal microamp range be on a flame rod pilot.

Français

Domaine(s)
  • Plomberie
OBS

Équivalent proposé par la compagnie Gaz Métropolitain.

Espagnol

Conserver la fiche 3

Fiche 4 2007-09-13

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
DEF

A combination gas pilot burner and flame rod flame detector; may also include an ignition electrode for spark ignition of the pilot, or a thermocouple adapter.

CONT

A pilot burner assembly comprises a pilot burner, a flame responsive means, and an electrode, all attached in close relationship to a common mounting bracket. The electrode is frictionally attached co-axially with an insulating sleeve and the sleeve is frictionally attached to the mounting bracket so that the spark gap between the tip of the electrode and a portion of the pilot burner is adjustable without having to bend the electrode.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

Le commutateur vérification-marche est situé au-dessus du module programmateur EP113 [...] et on peut l'utiliser pour arrêter la commande n'importe quand lors de sa séquence d'allumage sauf pendant MTFI (essai d'allumage du brûleur principal). [...] Ce commutateur facilite le réglage initial et la modification des réglages des tringleries du brûleur, de l'ensemble veilleuse, etc.

Espagnol

Conserver la fiche 4

Fiche 5 2006-01-20

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
  • Gas and Oil Heating
DEF

A furnace with condensing heat exchanger that condenses moisture from the flue gases resulting in greater efficiency.

CONT

The condensing gas furnace... operates at levels of efficiency of up to 95 per cent by condensing and recuperating the flue gases that would otherwise dissipate through the chimney. The condensing gas furnace also uses electrical ignition rather than a pilot flame, to minimize energy losses between combustion periods.

CONT

Condensing Gas Furnace. Gas furnaces shall be of natural gas fired warm air condensing type complete with casing, combustion chambers, fan and motor, space thermostats, controls, supply air filters, in-line intake and exhaust mufflers, hangers, brackets and structural supporting frames, etc., to provide tempered make-up air.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
  • Chauffage au gaz et au mazout
CONT

Les générateurs d'air chaud à condensation alimentés au gaz sont les appareils les plus efficaces offerts sur le marché, avec un rendement saisonnier de l'ordre de 90 à 97 p. 100. [...] Dans la plupart des modèles à condensation, le brûleur est semblable à celui d'un appareil ordinaire, le tirage étant assuré par un ventilateur à tirage aspiré. Toutefois, des surfaces d'échange thermique supplémentaires, faites de matériaux anticorrosion (généralement de l'acier inoxydable), extraient la chaleur des sous-produits de combustion avant leur évacuation. Là où se fait la condensation et l'échange thermique, les gaz de combustion sont refroidis au point où leur vapeur d'eau se condense, libérant ainsi plus de chaleur dans la maison. Le condensat est acheminé à un avaloir. [...] Les gaz de combustion sont alors suffisamment refroidis pour être évacués par un tuyau en plastique PVC ou ABS traversant un mur extérieur de la maison plutôt que par une cheminée.

Espagnol

Conserver la fiche 5

Fiche 6 2003-04-29

Anglais

Subject field(s)
  • Equipment (Chemistry)
  • Petroleum Technology - Equipment
CONT

The [Pensky-Martens closed cup] apparatus, [used for the determination of flash points of petroleum products] shall consist of a test cup, cover assembly, and stove... [The] pilot flame [is part of the cover assembly and is used] for automatic relighting of the exposure flame. A bead approximately 4 mm in diameter may be mounted on the cover so that the size of the test flame can be regulated by comparison.

Français

Domaine(s)
  • Équipement (Chimie)
  • Appareillage (Technologie pétrolière)
CONT

Appareil Pensky-Martens en vase clos. [...] L'appareil est constitué d'un vase d'essai, d'un couvercle et d'une étuve [...] [La] veilleuse [fait partie de l'ensemble couvercle et on l'utilise] pour réaliser l'allumage automatique du dispositif. Une perle d'environ 4 mm de diamètre peut être montée sur le couvercle de façon à pouvoir régler, par comparaison, la dimension de la flamme d'essai.

OBS

La perle peut être en ivoire ou en toute autre matière convenable.

Espagnol

Campo(s) temático(s)
  • Equipo (Química)
  • Equipo (Tecnología petrolera)
Conserver la fiche 6

Fiche 7 2000-06-30

Anglais

Subject field(s)
  • Measurements of Electricity
DEF

A rating applied to inductive loads (usually a solenoid or coil) with a maximum power factor of 35 percent. Allowable inrush can be up to 10 times the pilot duty rating (running current).

CONT

Engineering data. Supply voltage : 120 Vac(+10%/-15%) 50 or 60 Hz. Maximum total load : 2000 VA. Load rating-fuel valve output : 65 VA pilot duty plus 1150 VA inrush, 460 VA opening, 250 VA holding. Operating temperature limits :-40 to 140 °F. Maximum ambient humidity : 85% non-condensing. CB-780 Flame Safeguard Control.

Français

Domaine(s)
  • Mesures de grandeurs électriques

Espagnol

Conserver la fiche 7

Fiche 8 2000-06-20

Anglais

Subject field(s)
  • Burners and Steamfitting
OBS

Pilot flame-establishing period : the period of time in ignition trials during which the flame safeguard control permits the pilot valve to be open before the flame detector is required to detect the pilot flame.

Français

Domaine(s)
  • Fumisterie et brûleurs

Espagnol

Conserver la fiche 8

Fiche 9 2000-06-02

Anglais

Subject field(s)
  • Amplifiers (Electronics)
  • Electronic Measurements
  • Thermoelectricity and Thermoelectronics
  • Burners and Steamfitting
DEF

The part of the flame detection system which increases the flame signal to a magnitude sufficient to pull in the flame relay in the flame safeguard control. The amplifier may be a permanent part of the flame safeguard control, or it may be a replaceable, plug-in unit.

CONT

Hegwein pilot burners are compact, sturdy, and feature a modular design. Models are available with a built-in ignition transformer, or with both flame signal amplifier and ignition transformer.

OBS

Flame signal: the current measured at the meter jack of a flame signal amplifier in a flame safeguard control. The current is produced by the flame detector when it senses a flame.

OBS

Conventional multi-burner scanners have relied on the strength or amplitude of the flame signal to discriminate between burner flame-on and burner flame-off. This is most often done by using the amplitude output of the flame signal after bandpass or highpass filtering.

Français

Domaine(s)
  • Amplificateurs (Électronique)
  • Mesures électroniques
  • Thermoélectrique et thermoélectronique
  • Fumisterie et brûleurs

Espagnol

Conserver la fiche 9

Fiche 10 2000-05-25

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Safety Devices (Mechanical Components)
DEF

The components of a flame detection system which detect the presence or absence of a flame.

DEF

Component of a combustion safety control that senses flame.

OBS

A flame detector may be used, for example, as a flame failure device to shut down the gas supply to the main burner of a furnace when the pilot flame goes out.

Terme(s)-clé(s)
  • flame sensing element

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Organes de sécurité (Composants mécaniques)
DEF

Dispositif qui délivre un signal en fonction de la présence ou de l'absence d'une flamme.

CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc: [...] un appareil de commande (primary control), véritable cerveau du système. Il travaille en liaison avec le détecteur de flamme (flame detector).

CONT

Les équipements de sécurité comprennent: - les appareils de détection de la flamme par la température des fumées, par l'éclairement de la flamme; - les appareils de commande [...].

Espagnol

Conserver la fiche 10

Fiche 11 2000-04-28

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

The period of time in ignition trials during which the flame safeguard control permits the pilot valve to be open before the flame detector is required to detect the pilot flame.

Français

Domaine(s)
  • Fumisterie et brûleurs
OBS

Voir la fiche «temps de sécurité au démarrage du brûleur principal».

Espagnol

Conserver la fiche 11

Fiche 12 2000-04-28

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

A pilot flame which is supervised by a flame safeguard control that must detect the presence of the flame prior to permitting the main fuel valve(s) to open.

Français

Domaine(s)
  • Fumisterie et brûleurs

Espagnol

Conserver la fiche 12

Fiche 13 2000-04-28

Anglais

Subject field(s)
  • Safety Devices (Mechanical Components)
  • Control Instrumentation (Mechanical Components)
  • Burners and Steamfitting
DEF

A device for rapid automatic shutoff of all fuel, including igniters; may have manual or automatic initiation.

CONT

BurnerMaster systems are de-energize-to-trip(fail-safe) systems that provide furnace purge, ignitor(pilot) and main flame detection as well as control and monitoring of burner startup and shutdown sequences including master fuel trip.

Français

Domaine(s)
  • Organes de sécurité (Composants mécaniques)
  • Dispositifs de commande (Composants mécaniques)
  • Fumisterie et brûleurs
OBS

Brûleurs à gaz [...] Équipement et dispositif de sécurité [...] Un groupe de coupure de sécurité à fonctionnement automatique qui n'autorise le passage du gaz que lorsque tous les autres éléments fonctionnent normalement.

Espagnol

Conserver la fiche 13

Fiche 14 2000-04-28

Anglais

Subject field(s)
  • Gas and Oil Heating
  • Burners and Steamfitting
DEF

A test to determine if the smallest pilot capable of holding in the flame relay is large enough to safely light off the main burner.

OBS

turndown: the ratio of the maximum usable flow to the minimum controllable flow through a valve; usually somewhat less than the rangeability, as the maximum usable or required flow is usually less than the total flow capacity of a valve.

OBS

See record "valve turndown / marge de réglage effective."

Français

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fumisterie et brûleurs
OBS

Voir la fiche «marge de réglage effective / valve turndown».

Espagnol

Conserver la fiche 14

Fiche 15 2000-04-28

Anglais

Subject field(s)
  • Gas and Oil Heating
  • Burners and Steamfitting
DEF

Detecting the presence or absence of a pilot flame.

OBS

See record "flame safeguard system."

Français

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fumisterie et brûleurs
OBS

Le Sens-A-Flame est un système électronique de surveillance de flamme. Il détecte les défauts de flamme, enclenche une alarme et coupe l'alimentation en combustible. Il est disponible pour le contrôle de brûleurs séparés ainsi que de brûleurs multiples. Il comprend de nombreuses possibilités, sa technologie est complètement électronique, ses composants sont embrochables de façon à faciliter la maintenance. Il peut être utilisé avec électrode de flamme ou cellule U.V.

OBS

Voir la fiche «système de surveillance de flamme».

Espagnol

Conserver la fiche 15

Fiche 16 2000-03-31

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Combustion and Fuels (Fireplaces)
DEF

A pilot that burns throughout the entire time the burner assembly is in service, whether the main burner is firing or not. Upon a call for heat, the pilot flame is automatically increased in size so as to reliably ignite the main burner. This pilot may be turned down automatically at the end of the main burner flame-establishing period.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Combustion et combustibles (Foyers)

Espagnol

Conserver la fiche 16

Fiche 17 2000-02-28

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
DEF

The deterioration of the pilot to an unsatisfactory condition, characterized by a lazy, yellow flame; usually caused by a high ambient temperature or an excessively large pilot burner orifice.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout

Espagnol

Conserver la fiche 17

Fiche 18 1993-01-30

Anglais

Subject field(s)
  • Types of Aircraft
OBS

Angle control on the burner.

OBS

When crosswinds or gusts are felt, the pilot counteracts the deflection of the flame with the angle control of the burner.

Français

Domaine(s)
  • Types d'aéronefs
OBS

Normalement, le dispositif est une suspension à la cardan.

Espagnol

Conserver la fiche 18

Fiche 19 1991-10-31

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Security Devices
CONT

The high pressure(HP) flare which is 122 cm(48") in diameter is used to relieve pressure during emergencies. All relief valves and motor operated flare valves handling [hydrogen sulphide] are connected to the high pressure flare. The HP flare is first and foremost a safety and emergency system which will be used sparingly. The flare type is equipped with pilot lights which can be ignited electrically from the ground. Flame failures are detected by thermocouples, located at the tip and which actuate a flame failure alarm.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Dispositifs de sécurité
CONT

Stabilité des flammes de mélange préalable : [...] Le mélange préalable sort par l'orifice de sortie du brûleur, à une vitesse qui dépend de la pression d'alimentation et du réglage de l'admission de comburant. Pour une certaine pression, la flamme est stable au-dessus de l'orifice de sortie. [...] L'expérience montre que si la pression d'alimentation, et en conséquence la vitesse de sortie du mélange, prennent des valeurs de plus en plus élevées, il existe une valeur limite au-delà de laquelle la flamme devient instable; une partie de sa base commence à s'éloigner de l'orifice de sortie. Ce phénomène est appelé «limite de décollement de la flamme». Pour une valeur plus élevée de la vitesse de sortie, la flamme oscille dans l'espace à une certaine distance de l'orifice. Ce phénomène est appelé flamme aérienne. Si la vitesse de sortie augmente encore, la flamme ne peut plus trouver une position d'équilibre au-dessus du brûleur: elle s'éloigne et s'éteint. C'est le phénomène du «soufflage de la flamme».

Espagnol

Conserver la fiche 19

Fiche 20 1991-03-12

Anglais

Subject field(s)
  • Burners and Steamfitting
CONT

There are basically three types of pilot burners : 1) the millivolt; 2) the bi metal; and 3) the liquid filled.... The bimetal pilot is named so because of the sensing element. The sensing element is made of two dissimilar metals welded together so that they become one piece. The two metals have different expansion rates and this causes the two metals to bend when heated. As the bimetal element is heated by the pilot flame, a movable contact is pushed toward a stationary contact. When these contacts touch, an electrical circuit is completed through them. This control is usually employed to operate in the control, or low voltage, circuit.

OBS

bimetallic element: An element formed of two metals having different coefficient of thermal expansion, used as a temperature control device

Français

Domaine(s)
  • Fumisterie et brûleurs
OBS

[Brûleurs à gaz.] Détection de la température de la flamme [par] bilame. (...) Le bilame chauffé par la veilleuse se déforme et permet l'ouverture du clapet de gaz: ce dernier se dirige alors vers le brûleur,

Espagnol

Conserver la fiche 20

Fiche 21 1990-10-05

Anglais

Subject field(s)
  • Burners and Steamfitting
CONT

[Oil burner] Ignition is generally accomplished by an electric spark, gas pilot flame, or oil pilot flame.

Français

Domaine(s)
  • Fumisterie et brûleurs
CONT

Dans les brûleurs automatiques et dans les brûleurs par tout ou rien, l'allumage du mélange combustible s'effectue, par étincelle électrique provenant de deux électrodes installées au bec du brûleur.

Espagnol

Conserver la fiche 21

Fiche 22 1990-10-02

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Safety Devices (Mechanical Components)
DEF

A flame safeguard control which starts the burner in the proper sequence, proves that the burner flame is established, and supervises the flame during burner operation. It causes safety shut-down on failure to ignite the pilot or main burner or on loss of flame.

DEF

A safety control responsive directly to flame properties, sensing the presence or absence of flame and, in event of ignition failure or unintentional flame extinguishment, causing safety shutdown.

DEF

Automatic safety control intended to prevent abnormal discharge of fuel at the burner in the event of ignition or flame failure.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Organes de sécurité (Composants mécaniques)
CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc : [...] un appareil de commande (primary control), véritable cerveau du système [qui] travaille en liaison avec le détecteur de flamme (flame detector). [L'appareil de commande] assure le démarrage, l'état de régime, l'arrêt par régulation, l'arrêt dû à un dérangement ou la mise sous sécurité du brûleur sur commande d'organes extérieurs de régulation tels que thermostats, d'organes de sécurité tels que détecteurs de flamme, nanostats, etc.

Espagnol

Conserver la fiche 22

Fiche 23 1990-08-29

Anglais

Subject field(s)
  • Burners and Steamfitting
CONT

Horizontal Rotary-Atomizing Burner.... The burner consists of an atomizing or spinner cup, and air blower, and a region in which the air and oil are mixed. The cup, which is mounted on a horizontal motor shaft, is revolved at a speed of 3, 450 revolutions per minute or higher. The oil fed to the cup is atomized by whirling the oil off the edge of the cup. As the oil droplets leave the edge, they are caught up in a horizontal air current from the blower. The resulting fuel-air mixture is ignited by a gas pilot near the cup, and the flame is projected horizontally.

CONT

horizontal rotary burner. ... This burner receives its name from the fact that it enters the boiler on a horizontal plane ... and prepares the oil for combustion by centrifugal force, spinning it off a [rotating] cup....

Français

Domaine(s)
  • Fumisterie et brûleurs
CONT

Les brûleurs rotatifs sont du type vertical ou du type horizontal. La vaporisation est assurée par la force centrifuge. L'huile arrive dans une cuvette rotatoire où elle tourbillonne très rapidement jusqu'à ce qu'elle en soit projetée. Mélangée à l'air et au contact des électrodes l'huile s'allume.

OBS

(...) coupelle à axe horizontal (...).

OBS

(...) il existe de nombreuses marques de brûleurs à coupelle rotative (...) compte tenu des multiples variantes concernant: 1. La machine motrice (...) 2. L'alimentation de la coupelle (...). 3. La disposition de l'arbre principal qui peut être: - soit horizontal (...) - soit vertical (...).

Espagnol

Conserver la fiche 23

Fiche 24 1986-06-18

Anglais

Subject field(s)
  • Control Instrumentation (Mechanical Components)
  • Burners and Steamfitting
DEF

A flame safeguard control that adds a timing function to the primary control to sequence additional burner functions such as prepurge, postpurge, timed trials for pilot and main burner flame, and firing rate switching.

Terme(s)-clé(s)
  • programing control
  • programer

Français

Domaine(s)
  • Dispositifs de commande (Composants mécaniques)
  • Fumisterie et brûleurs
CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc : (...) un programmateur [qui permet] de programmer la séquence de fonctionnement du brûleur et de l'équipement qui lui est asservi (vannes, ventilateur, etc.).

Espagnol

Conserver la fiche 24

Fiche 25 1986-06-18

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Burners and Steamfitting
DEF

a safety control which provides a means for starting the burner in the proper sequence, proving that the pilot or burner flame is established, and supervising the flame during burner operation. Safety shutdown occurs if the pilot or burner flame is not established, or if the flame goes out.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Fumisterie et brûleurs
CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc : (...) des dispositifs de commande et de sécurité (flame safeguard control) de deux genres : - un appareil de commande (primary control), véritable cerveau du système. Il travaille en liaison avec le détecteur de flamme (flame detector). (...) - un programmateur (programming control; programmer). Il accomplit les mêmes fonctions que l'appareil de commande, mais permet, en outre, de programmer la séquence de fonctionnement du brûleur et de l'équipement qui lui est asservi (vannes, ventilateur, etc.).

Espagnol

Conserver la fiche 25

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :