TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

SUPERFUND SITE [3 fiches]

Fiche 1 2017-01-26

Anglais

Subject field(s)
  • Anti-pollution Measures
CONT

The increasing concentration of 1,2-DCP detected in Village production wells concerned SWDO’s Division of Drinking and Ground Water (DDAGW). In the summer of 1997, DDAGW requested that Ripley take action to reduce the concentration of 1,2-DCP to below 5.0 µg/l. Failure to do so would lead to requirements for costly treatment. The most viable option for the village was determined to be the installation of a interception well as a temporary method to capture the 1,2-DCP plume before it reaches the well field.

CONT

... at the time, it was indicated that interceptor wells were being dug on the site to determine whether or not there would be contamination of the surrounding water table.

CONT

Last month, the federal Environmental Protection Agency directed Union Carbide to install an "interceptor well, "in the well field, which is located off Dugan Lane near the Garden State Parkway. A plume of ground water contamination from the nearby Reich Farm Superfund site has seeped into the well field. Craig A. Wilger, Carbide's project manager for the Reich Farm site, said Carbide consultant Jon Sykes is trying to determine the best placement for an interceptor well by using a computer model of ground water in the area.

Français

Domaine(s)
  • Mesures antipollution
CONT

Problème(s) : Découverte d'hydrocarbures dans l'eau des puits d'un lotissement rural. [...] Matrix a réalisé des essais pilotes et la modélisation de l'écoulement des eaux souterraines dans le but de concevoir et d'installer un réseau de 16 puits d'interception pour récupérer les eaux souterraines contaminées.

CONT

Captage par puits ou forages. L'utilisation de ce type de captage est chronologiquement celui qui a été mis en œuvre en dernier lieu (1904) en vue de l'exploitation des ressources des sables bruxelliens. Selon qu'il est réalisé par sondage ou par creusement, l'ouvrage captant est dénommé forage ou puits de captage. [...] Alors que le diamètre intérieur des forages varie entre 400 et 1000 mm, celui des puits de captage peut atteindre 5 m. Fort variable, la profondeur des forages peut atteindre jusqu'à 60 m. Celle des puits est généralement plus faible.

CONT

L'exploitant a réalisé au cours des derniers mois d'importants travaux consistant à restructurer le réseau d'évacuation des eaux, d'une part, et à déplacer le puits de captage des eaux industrielles (conformément à une étude hydrogéologique préalable) d'autre part.

CONT

L'ARAP [Administration du rétablissement agricole des Prairies] continue de travailler avec le ministère de l'Agriculture, de l'Alimentation et du Développement rural de l'Alberta, Protection de l'environnement Alberta et l'industrie des puits de captage des eaux souterraines pour promouvoir la durabilité des puits pendant des générations.

Espagnol

Conserver la fiche 1

Fiche 2 2004-02-16

Anglais

Subject field(s)
  • Analytical Chemistry
  • Environmental Studies and Analyses
CONT

Mr. Dodge is experienced with an environmental forensics technique called chemical fingerprinting. He has used this technique to identify potentially responsible sources of dioxins at a multi-party Superfund site and the potential sources of dioxins and PCBs impacting a Venice Lagoon in Italy.

CONT

Can these PCB analyses be used for anything other than just describing the environmental situation in the area where the samples were taken? Is it possible to find out who produced the environmental toxin? Is there a "fingerprint" at the pollution "crime scenes" along the coast? The answer to all these questions was an emphatic yes. The idea behind the so-called "chemical fingerprinting" is simple: PCB is not an individual substance but a collective term for 209 different environmental toxins. PCB manufacturers produced a variety of PCB blends. Konieczny’s method is just as simple if we know the composition of the blends, we can also locate them today.

CONT

Chemical Fingerprinting in the Environment. ... Problem: Determine if the origin of chemicals found at field sites can be traced to specific chemical sources/processes. Project Activity Scope ... Interaction mechanisms through Measurement & Analysis System Applications. PNNL Solution: Evaluated chemicals present at site. Used chemical database to estimate chemical stability & reactions at site. Analyzed co-present chemicals to project back-in-time to identify & estimate source contributions. Successfully performed analysis at several waste sites.

Terme(s)-clé(s)
  • chemical finger printing

Français

Domaine(s)
  • Chimie analytique
  • Études et analyses environnementales
CONT

[...] la maîtrise des dépôts moléculaires vers des zones prédéfinies d'une surface est un enjeu important si l'on envisage de bâtir des dispositifs électroniques. L'équipe «Systèmes Moléculaires Organisés» fait ainsi appel aux ressources conjuguées de la lithographie électronique classique et de la lithographie «douce» (technique d'empreinte chimique) pour forcer l'adsorption sélective de vésicules ou de nanotubes de carbone et contrôler les dépôts moléculaires.

CONT

Les sédiments d'un lac où les saumons étaient abondants contenaient dix fois plus de BPC que les sédiments d'un lac voisin sans saumons. La détermination de l'empreinte chimique du type de BPC identifie clairement les poissons comme la source des BPC contenus dans les sédiments.

OBS

Les différentes techniques scientifiques utilisées dans les laboratoires de sciences légales sont devenues des outils indispensables pour l'établissement de la preuve et de la vérité. L'empreinte chimique est aussi fiable pour l'identification et la confirmation de la présence d'une substance que l'est une empreinte digitale pour l'identification d'un suspect.

OBS

Le spectre du carbone peut [...] servir d'empreinte chimique dans l'analyse microscopique de composés polymères, de grande importance pour l'industrie chimique.

Espagnol

Conserver la fiche 2

Fiche 3 2001-06-28

Anglais

Subject field(s)
  • Waste Management
CONT

Pyretron oxygen burner demonstrated at a Superfund site.

Français

Domaine(s)
  • Gestion des déchets
CONT

[Le] système de brûleur d'oxygène Pyretron a été démontré sur un site du Superfund.

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :