TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

ULTRA STABILITY [2 fiches]

Fiche 1 2009-08-03

Anglais

Subject field(s)
  • Lasers and Masers
CONT

The PHM is an atomic clock with outstanding stability for averaging times from 1 to 100, 000 seconds, to be used in precise positioning, time keeping and other on-boards applications. It is designed to perform in space environment for not less than 12 years. The operating principle exploits the stimulated energy emission occurring during the hyperfine transition of the atomic hydrogen in a miniaturised microwave cavity. The ultra stable RF [Radio Frequency] generated signal, at the frequency of 1420. 4057517.. MHz [megahertz], is used as a reference in a frequency synthesiser to generate the 10 MHz standard reference frequency.

OBS

The PHM is the most stable spaceborne atomic clock ever developed for an operational programme. The PHM is the master clock for the ESA/EU [European Space Agency/Europe] Galileo Navigation System.

Terme(s)-clé(s)
  • passive hydrogen maser

Français

Domaine(s)
  • Masers et lasers
CONT

GIOVE-B transporte à son bord deux horloges atomiques au rubidium et un maser à hydrogène passif [PHM], l'horloge atomique la plus précise au monde, toutes trois conçues et réalisées par la société neuchâteloise SpectraTime, filiale du groupe Orolia. Ces horloges constituent la base de temps des satellites, et donc l'élément clé de ce premier système de navigation européen. Elles permettent d'atteindre une stabilité de moins de 10 milliardièmes de secondes par jour. « C'est la première fois qu'un tel maser à hydrogène passif (PHM) est envoyé dans l'espace, et c'est lui qui donnera à Galileo ses performances uniques au monde. Pour donner un point de comparaison, nos horloges sont 10 millions de fois plus précises qu'une montre à quartz » [...] SpectraTime.

OBS

Le second satellite expérimental du système européen de positionnement par satellite Galileo, destiné notamment à tester l'horloge atomique la plus précise jamais placée en orbite à ce jour, a été lancé avec succès le 27 avril 2008 dernier du centre spatial de Baïkonour. Ce satellite de test, baptisé GIOVE-B (Galileo In-Orbit Validation Element) [...] Galileo, premier système européen de navigation et de positionnement par satellite [...] sera compatible avec les deux autres systèmes de navigation par satellite couvrant l'ensemble du globe : le système américain GPS et le système russe Glonass.

OBS

Le maser ("Microwave Amplification by Stimulated Emission of Radiation") à hydrogène est une horloge atomique extrêmement stable basée sur l'atome d'hydrogène. Il a été inventé par Kleppner et Ramsey en 1960 à l'université de Harvard. Le principe de fonctionnement est semblable à celui du LASER sauf que la radiation émise est une radiation micro-onde et non pas optique. Le maser à hydrogène est utilisé principalement en radioastronomie et en géodésie comme horloge pour la synchronisation de radiotélescopes utilisant la technique du VLBI (Very Long Base Interferometry). Il est utilisé également pour la poursuite des sondes planétaires (Deep Space Tracking). Dans le futur, il pourrait être utilisé dans les systèmes de navigation par satellite de type GPS à cause de sa très grande stabilité (cf l'avenir du temps atomique ).

Espagnol

Conserver la fiche 1

Fiche 2 2001-09-27

Anglais

Subject field(s)
  • Scientific Instruments
  • Scientific Measurements and Analyses
  • Optics
CONT

Ultra High Resolution Spectrometer(UHRS).... Laser spectroscopy has stimulated the development of spectrometers with improved performance and has led SOPRA to develop a new line of monochromators with ultra-high resolution. SOPRA has designed the mechanical parts in the most careful way to take the best advantage of the newest diffraction gratings. The instrument function of a monochromator is defined by the product : Resolution X Luminosity/Noise=RL/N. The resolution R directly depends on the diffraction grating and the focal length. The luminosity L depends on the area, on the efficiency of the grating, and on the slits. The noise N is essentially caused by the light scattered by the grating through the output slit and it diminishes when the focal length is increased. Another crucial quality factor of a monochromator is the ease to use it, i. e. its stability and reproducibility with regard to resolution and luminosity, and its tuning characteristics.

Français

Domaine(s)
  • Instruments scientifiques
  • Mesures et analyse (Sciences)
  • Optique
CONT

Nous disposons d'un spectromètre à ultra-haute résolution dans le domaine spectral de 10 mm, dont nous améliorons régulièrement les performances, et qui nous a permis des travaux originaux en physique moléculaire et en métrologie des fréquences.

Espagnol

Conserver la fiche 2

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :