TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

VACUUM TEST CHAMBER [9 fiches]

Fiche 1 2015-02-19

Anglais

Subject field(s)
  • Scientific Instruments
  • Physics
OBS

High vacuum is vacuum where the MFP(mean free path) of residual gases is longer than the size of the chamber or of the object under test. High vacuum usually requires multi-stage pumping and ion gauge measurement.

Français

Domaine(s)
  • Instruments scientifiques
  • Physique
OBS

Le vide secondaire est le vide obtenu par la pompe dite secondaire dans une installation. Son domaine est classiquement celui des pompes à diffusion et des pompes turbomoléculaires, c’est-à-dire celui du vide poussé (10-1 Pa à 10-5 Pa).

Espagnol

Conserver la fiche 1

Fiche 2 2015-02-19

Anglais

Subject field(s)
  • Scientific Instruments
  • Physics
OBS

High vacuum is vacuum where the MFP(mean free path) of residual gases is longer than the size of the chamber or of the object under test. High vacuum usually requires multi-stage pumping and ion gauge measurement.

Français

Domaine(s)
  • Instruments scientifiques
  • Physique

Espagnol

Conserver la fiche 2

Fiche 3 2014-02-03

Anglais

Subject field(s)
  • Thermodynamics
  • Combustion and Fuels (Fireplaces)
CONT

The cold soak filtration test determines if biodiesel shows precipitate formation upon cooling to temperatures above the cloud point.

OBS

The test is performed by placing 300 mL of biodiesel in a 500-mL glass bottle. The sample is then set in a liquid or air bath or chamber at 40 °F for 16 hours. The sample is then allowed to come to room temperature(around 70 °F) and filtered through a 47-mm diameter and 0. 7-μm nominal pore-sized glass fiber filter under vacuum of 25 inches of mercury under atmospheric pressure. The time required to filter 300 ml of biodiesel is reported.

Français

Domaine(s)
  • Thermodynamique
  • Combustion et combustibles (Foyers)
CONT

Essai de filtration par trempage à froid (EFTF) – Exigence la plus présente dans l’ASTM [American Society for Testing and Materials] D6751. Elle a été ajoutée en 2008 à la suite de l’obtention de données indiquant que certains mélanges de type B100 pouvaient former des précipités au-dessus du point de trouble. Dans des mélanges de pétrodiesel allant jusqu’à une teneur de 20 %, un mélange de type B100 satisfaisant aux exigences de la filtrabilité par trempage à froid ne forme aucun précipité.

Espagnol

Conserver la fiche 3

Fiche 4 2009-02-10

Anglais

Subject field(s)
  • Space Exploration Equipment and Tools
CONT

This thermal vacuum chamber is used for testing of spacecraft subsystems and components... Gaseous helium shroud(horizontal cylinder) : for deep cryogenic(20 K nominal) applications fits within liquid nitrogen shroud [;] working volume : 1. 8 m diameter x 1. 8 m deep(6 x 6 ft) [;] cooling capacity : 400 W [;] temperature : two controllable setpoints of 100 K(-173 degrees C/-280 degrees F) and 20 K(-253 degrees C/-424 degrees F) [;] equipped with four translational shutters to enable the unit under test to have a short term view factor of the outside environment.

Français

Domaine(s)
  • Équipement et outillage d'exploration spatiale
CONT

Caisson TV3 (2,5x2,5). Ce caisson de vide thermique est utilisé pour mettre à l'essai divers éléments et sous-systèmes d'engins spatiaux. [...] Coiffe d'hélium gazeux (cylindre horizontal) : pour les applications de cryogénie poussée (température nominale de 20 K) [;] s'insère à l'intérieur de la coiffe d'azote liquide [;] volume utile : 1,8 m de diamètre x 1,8 m de haut (6 pi x 6 pi) [;] capacité de refroidissement : 400 W [;] température : deux réglages prédéterminés de 100 degrés Kelvin (-173 °C /-280 °F) et de 20 degrés Kelvin (-253 °C/-424 °F) [;] caisson doté de quatre volets coulissants afin de permettre à l'unité testée d'obtenir un facteur de forme à court terme de l'environnement extérieur.

Espagnol

Conserver la fiche 4

Fiche 5 2008-07-23

Anglais

Subject field(s)
  • Spacecraft
CONT

A thermal vacuum test on the first flight vehicle of the H-II Transfer Vehicle(HTV) has been carried out at the Spacecraft Integration and Test Building at the Tsukuba Space Center. The purpose of the test is to evaluate the thermal design of the structure and to verify its endurance in the harsh environment of space by stimulating the vacuum and thermal environment in space. Thermal vacuum test for the Pressurized Carrier and Unpressurized Carrier have already been completed, and the main part of Avionics Module and Propulsion Module combined is now in the 13-meter diameter space chamber for testing.

Français

Domaine(s)
  • Engins spatiaux
OBS

test de vide thermique : terme uniformisé par le Comité d'uniformisation de la terminologie spatiale - CUTS.

Espagnol

Conserver la fiche 5

Fiche 6 2003-08-18

Anglais

Subject field(s)
  • Research Experiments in Space
CONT

The Rocket Assembly/Checkout Facility... The facility consists of six contiguous laboratory modules subdivided into a storage area, a gray room area, and a clean room. The storage area houses spare instrument components and intermittently used ground support equipment. The gray room area contains facilities to clean components before they enter the clean room and equipment used to ship the instrument to WSMR [White Sands Mission Range]. The Class 100 cross-flow clean room is separated from the gray room by an air shower. The clean room contains three major stations : a clean bench for assembly of subsystems; a 12x14-ft optical bench for instrument assembly and electronic test of the instrument subsystems; and a vacuum chamber for vacuum focus and spectroradiometric calibration. The cryogenically pumped vacuum chamber is designed with a 30-cm diameter ultraviolet collimator at one end and a roll-off section that accommodates the entire flight instrument centered in the collimated beam at the other end.

Français

Domaine(s)
  • Travaux de recherche dans l'espace

Espagnol

Conserver la fiche 6

Fiche 7 2003-02-27

Anglais

Subject field(s)
  • Scientific Research Equipment
  • Engineering Tests and Reliability
  • Thermoanalysis
CONT

Thermal Vacuum Test Chamber... The purpose of the Thermal Vacuum test is to verify that the satellite will work correctly in the extreme temperatures and low pressures experienced in space. The satellite is suspended from a test fixture in the center of the tank, which is pumped out to a pressure about a billion times smaller than atmospheric pressure. The entire chamber wall can be heated and cooled to simulate the effects of solar heating when the satellite is in sunlight and the cold of outer space when the satellite is in the shadow of the Earth.

Français

Domaine(s)
  • Matériel et équipement (Recherche scientifique)
  • Fiabilité, contrôle et essais (Ingénierie)
  • Thermo-analyse

Espagnol

Conserver la fiche 7

Fiche 8 2002-04-11

Anglais

Subject field(s)
  • Scientific Research Equipment
  • Engineering Tests and Reliability
CONT

The purpose of the operational qualification is to verify the proper operation of the Steam Sterilizer and to ensure conformance to design specifications and process requirements in compliance with applicable GMP regulations. The following tests are performed :... Vacuum Leak test to verify the integrity of the Autoclave chamber.

CONT

... Field Autoclave ... 2 test programmes for vacuum leak test and Bowie Dick sterility test.

Français

Domaine(s)
  • Matériel et équipement (Recherche scientifique)
  • Fiabilité, contrôle et essais (Ingénierie)
CONT

Autoclaves. [...] Le test d'étanchéité au vide ou «test de vide» consiste à faire un vide suffisant dans la chambre de stérilisation et à vérifier qu'il se maintient pendant 10 minutes sans variation significative, attestant de l'étanchéité au vide de l'appareil.

Espagnol

Conserver la fiche 8

Fiche 9 1998-04-01

Anglais

Subject field(s)
  • Engineering Tests and Reliability
  • Welding and Soldering (Metals)
  • Inspection for Defects (Materials Engineering)
DEF

A device used to assess the integrity of field seams in membrane liners.

CONT

Seam Testing Methods... Vacuum chamber(boxes) have been used where a 3-ft-long box with a transparent top is placed over the seam and a vacuum of approximately 2. 5 lb/in. superscript 2] applied. When a leak is encountered the soapy solution originally placed over the seam shows bubbles. These bubbles are due to air entering from beneath the liner and passing through the unbonded zone. The test is slow to perform and it is often difficult to make a vacuum-tight joint at the bottom of the box where it passes over the seam edges.

Français

Domaine(s)
  • Fiabilité, contrôle et essais (Ingénierie)
  • Soudage (Métal)
  • Détection des défauts des matériaux
DEF

Enceinte dans laquelle on peut faire le vide ou seulement créer une dépression et dans laquelle on place la surface à essayer badigeonnée d'un liquide mouillant. Cette surface est examinée à travers un hublot permettant d'observer l'absence ou l'apparition de bulles.

CONT

Contrôle d'étanchéité de soudure sur membrane bitumineuse au moyen d'une cloche à vide.

Espagnol

Conserver la fiche 9

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :