TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

VAPOR DETECTOR [10 fiches]

Fiche 1 2012-01-16

Anglais

Subject field(s)
  • Analytical Chemistry
  • Phraseology
  • Electrical Engineering
OBS

... Winefordner et al. described a special, more sensitive cell based on changes in dielectric constant and constructed to allow gas flow between the plates of a capacitor which is a part of the tank circuit of a 70-Mc/sec Clapp oscillator, the output of which is beat against that of a reference oscillator. With the difference frequency between oscillators adjusted to zero with pure carrier gas flowing through the detector, the presence of a foreign vapor in the cell will produce a different frequency which is linearly related to the amount of material introduced through an injection port in the carrier gas stream and inversely proportional to the absolute temperature for a given component at a constant density or concentration in the cell and for a particular operating frequency.

PHR

Reference, sample Clapp oscillator.

Français

Domaine(s)
  • Chimie analytique
  • Phraséologie
  • Électrotechnique

Espagnol

Conserver la fiche 1

Fiche 2 2012-01-04

Anglais

Subject field(s)
  • Weather Stations and Meteorological Instruments and Equipment
  • Atmospheric, Climatic and Meteorological Phenomena
DEF

A hygrometer which determines the amount of precipitable moisture in a given region of the atmosphere by measuring the attenuation of radiant energy caused by the absorption bands of water vapor; the instrument consists of a collimated energy source, separated by the region under investigation and a detector which is sensitive to those frequencies that correspond to the absorption bands of water vapor.

Français

Domaine(s)
  • Stations, instruments et équipements météorologiques
  • Phénomènes météorologiques, climatiques et atmosphériques
DEF

Hygromètre qui détermine le contenu de l'atmosphère en vapeur d'eau en mesurant le spectre d'absorption de celle-ci.

CONT

Un des principaux points de l'étude de site réalisée au Grand Bénare fut la mesure de la quantité de vapeur d'eau atmosphèrique grâce à un hygromètre spectral.

Espagnol

Conserver la fiche 2

Fiche 3 2011-09-26

Anglais

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Scientific Instruments
CONT

A Geiger-Mueller(GM) tube is a gas-filled radiation detector. It commonly takes the form of a cylindrical outer shell(cathode) and the sealed gas-filled space with a thin central wire(the anode) held at [approximately] 1 kV [kilovolt] positive voltage with respect to the cathode. The fill gas is generally argon at a pressure of less than 0. 1 atm [atmosphere] plus a small quantity of a quenching vapor

Français

Domaine(s)
  • Physique radiologique et applications
  • Instruments scientifiques
CONT

[Détection et mesures des rayonnements nucléaires.] Gaz de remplissage : son choix est important puisque le développement de l’avalanche dépend largement de la dérive des électrons primaires. Toute trace d’oxygène doit être proscrite et on utilise le plus souvent un gaz rare (comme Ar [argon] ou Kr [krypton] ou Xe [xénon]) pour augmenter l’efficacité s’il s’agit de détecter des photons. Pour la détection des neutrons, on utilise d’autres gaz moins classiques. Ce gaz est souvent enfermé dans une enceinte scellée (emploi plus commode) ou peut être recyclé en permanence dans le compteur (dans la détection des particules chargées en particulier).

Espagnol

Conserver la fiche 3

Fiche 4 2010-04-27

Anglais

Subject field(s)
  • Weather Stations and Meteorological Instruments and Equipment
  • Metrology and Units of Measure
CONT

A particularly sensitive and accurate type of hygrometer has been developed in recent years by the Instrument Division of the U. S. Weather Bureau. The device, known as the infrared hygrometer, employs a beam of infrared light projected through the air to a photo-electric detector. Two separate wave lengths of light are used; one is absorbed by water vapor and the other passes through undiminished. The ratio of the infrared light transmitted by the different wave lengths is a direct indication of the amount of water vapor in the light path.

Français

Domaine(s)
  • Stations, instruments et équipements météorologiques
  • Unités de mesure et métrologie
OBS

L'un des meilleurs hygromètres, mais aussi le plus coûteux, mesure sur un trajet optique de l'ordre du mètre le rapport d'une raie d'absorption intense de la vapeur d'eau dans l'infrarouge moyen à celle d'une bande très voisine non absorbée.

Espagnol

Conserver la fiche 4

Fiche 5 2002-11-29

Anglais

Subject field(s)
  • Measuring Instruments
  • Security Devices
DEF

A mercury vapour analyzer which is used to measure the mercury level in the air.

CONT

Health & Safety has a Jerome mercury detector that will be used to check the mercury vapor concentration.... Compact high intensity mercury(HIM) tubes may release significant amounts of mercury vapors if they break while being used inside electronic equipment. If a HIM tubes breaks while in use, evacuate the laboratory and contact Health & Safety to monitor mercury vapor concentration inside the room with the Jerome mercury detector.

Français

Domaine(s)
  • Appareils de mesure
  • Dispositifs de sécurité
CONT

Détecteur au mercure, fabriqué en plastique, pour la protection des grandes fenêtres [...].

CONT

Détecteur d'inclinaisons contenant des détecteurs au mercure avec émetteur radio codée. [Serrure] conçue pour la protection de tableaux ou autres propriétés de valeur amovibles.

Espagnol

Conserver la fiche 5

Fiche 6 1998-05-14

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

As a means of exciting noble gases at atmospheric pressures, Lovelock developed a spark device of high sensitivity, capable of detecting as little as 10minus 13 mole of most organic materials. The detector consisted of a spark gap made of platinum wire sealed in a glass tube. The voltage across the 5-10 mm spark gap is measured with an electrostatic voltmeter. With pure argon subjected to an applied voltage of 2000 V to create sparks, the breakdown potential measured was logarithmically related to the concentration of vapor added to the argon.

OBS

Karmen and Bowman developed a dc discharge detector based on a low-current electric discharge in argon or helium in the presence of a high-intensity electrostatic field ... Sternberg and Poilson developed a Tesla discharge detector ... Evrard, Thevelin, and Joossens described a nonradioactive, self-sustained discharge detector for the detection of permanent gases.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 6

Fiche 7 1996-05-13

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Semiconductive Thin Film Detector. Using the known principle that the adsorption and desorption of gases cause a change in electrical conductivity of semiconductors, Seiyama et al. developed a new chromatographic detector for gaseous components.... The current, depending upon the resistance of the film, is converted to voltage by the variable resistance, which is fed without amplification to a recorder. Resistance also adjusts the input voltage of the recorder at desired sensitivity. Using zinc oxide as an example of a typical film material, the conductivity of its film maintains a fixed value when the nitrogen carrier gas is passed at a constant flow rate throught the borosilicate glass tube. When a small amount of another gas or vapor is added to the carrier gas, its conductivity is changed.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 7

Fiche 8 1996-03-08

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Lovelock developed a small detector intended for use with open tubular columns, and a new triode detector having a sensitivity 1000 times greater than his original detector... The triode detector... incorporates a ring electrode, in addition to the normal anode and cathode electrodes, which separates the background current(positive ions liberated by vapor/metastable argon reactions or collisions) of the primary electron stream from the signal current. Basically, both detectors are similar to the simple device in design : their brass or stainless steel chambers function as cathodes; their anodes of the same material are supported coaxially within the chamber by a polytetrafluoroethylene insulator; both contain ports for introduction and escape of the chromatographic column gas effluent from the detectors; and each have a suitable source of alpha or beta radiation.

Terme(s)-clé(s)
  • Lovelock's detector

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 8

Fiche 9 1996-03-08

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

The detector cell consisted of two circular plates. One was a 0. 0005-in nickel foil disk functioning as the sensor plate; the other, a 0. 002-in. gold foil disk, is called the vibrating plate. The gold disk is vibrated at 12 cps to produce alternating current readings for the oscilloscope, whereas the nickel sensor is thermically cycled by current surges. A 0. 10-in. mica spacer separates the plates so that vapor can be passed between them.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 9

Fiche 10 1996-03-08

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

This increase in electrical conductivity resulted from the release of sodium vapor from the probe. Using a two-stage flame detection system, one flame placed above the other but separated from it by a sodium hydroxide-treated wire mesh screen, hydrogen gas was added to the effluent of the column, and the carrier gas-air-hydrogen mixture was burned in the lower flame detector with its resulting electrical conductivity being the same as that of the usual flame detector.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 10

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :