CONT

After closing and sealing the door, setting the timer, and pulling out the operating handle, the steam inlet valve from the boiler opens, allowing steam at a pressure of 6 psi to enter the compartment. Air from the sealed compartment exits through the vent until the temperature reaches 180°F; then the vent closes and the compartment can become pressurized.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Robinetterie et accessoires
  • Appareils de cuisson des aliments
CONT

Une fois le temps de cuisson écoulé, interrompre l'admission de vapeur progressivement en ramenant lentement la manette en position première; ceci a pour effet de fermer le robinet d'admission de vapeur et d'ouvrir le robinet de purge ou de vidange.

Espagnol

Conserver la fiche 1

Fiche 2 2007-08-03

Anglais

Subject field(s)
  • Burners and Steamfitting
CONT

A floating flame is an indication that there is a lack of secondary air to the flame. In severe cases, the flame will leave the burner and have the appearance of a floating cloud. Again, the intermediate products of combustion are apt to escape from place to place wherever sufficient air for combustion may be found. This flame is sometimes hard to detect because, as the door to the equipment is opened sufficient air will be admitted to allow the flame to rest on the burner properly. However, the obnoxious odor of aldehydes may still be detected. Another possible cause of this flame is an improperly operating vent system. If the products of combustion cannot escape, fresh air cannot reach the flame

CONT

When a flame raises off the burner it is important to determine if it is a "lifting flame" or a "floating flame": "Lifting Flames" rise from the ports to burn some distance above the ports. In some cases these flames will drop back to the port and lift again intermittently. They are caused by too much primary air. Decreasing the shutter opening will stop lifting flames. "Floating Flames" are long and lazy looking, poorly defined, quiet flames which roll around the combustion chamber sometimes completely off the ports. Floating flames result from too little secondary or "make up" air. Lack of secondary air can be caused by incorrect venting, clogged flueways, blocked secondary air inlet openings, or lack of natural room makeup air to the oven.

Français

Domaine(s)
  • Fumisterie et brûleurs

Espagnol

Conserver la fiche 2

Fiche 3 2005-07-25

Anglais

Subject field(s)
  • Food Preservation and Canning
  • Food Industries
  • Industrial Tools and Equipment
CONT

Retorts are generally large vessels into which a product is placed for processing or cooking with relatively low pressure steam. An example would be a canning retort into which sealed tins of food are placed. Steam is then used to heat or cook the contents of the can. Once the door is closed, it is vital to ensure that all the air and condensate is removed and replaced by dry saturated steam. A float-thermostatic trap(with its inbuilt air vent) is ideal, especially due to its ability to pass large volumes of condensate at relatively low pressure...

Français

Domaine(s)
  • Conservation des aliments et conserverie
  • Industrie de l'alimentation
  • Outillage industriel

Espagnol

Conserver la fiche 3

Fiche 4 1985-10-23

Anglais

Subject field(s)
  • Gas and Oil Heating
  • Ovens, Furnaces and Boilers (Heating)
CONT

With conventional gas furnaces, little can be done to prevent losses of heated house air up the chimney when the furnace is firing. What can be prevented, though, is the loss that occurs when the furnace is not firing. A positive vent damper consists of a tight-fitting hinged damper door mounted in a steel collar and fitted into the flue pipe just before the pipe enters the chimney base. A fail-safe interlock switch prevents the furnace from firing unless the damper is completely open. This device may also be used with propane furnace.

Français

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fours et chaudières (Chauffage)

Espagnol

Conserver la fiche 4

Fiche 5 1980-07-05

Anglais

Subject field(s)
  • Flight Controls (Aeroindustry)
OBS

perform following steps to remove ac motor-driven hydraulic reciprocating pump assembly(ac hydraulic pump) :(...) Open hydraulic access door F321 and depress vent valve(reservoir air bleed valve) above reservoir No. 2.

Français

Domaine(s)
  • Commandes de vol (Constructions aéronautiques)

Espagnol

Conserver la fiche 5

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :