VENTILATION STOP [4 fiches]

Fiche 1 2021-05-11

Anglais

Subject field(s)
  • Fire-Fighting Techniques
DEF

A defensive tactic that involves cutting an exit opening in the roof of a burning building, extending from one outside wall to the other, to create an opening at which a spreading fire may be cut off.

CONT

Trench ventilation(also called strip ventilation) is used in a slightly different way than the conventional vertical ventilation techniques … Conventional vertical ventilation is used primarily to remove heated smoke and gases from the structure and is best done directly above the fire. Trench ventilation is used to stop the spread of fire in a long, narrow structure. Trench ventilation is performed by cutting a large opening, or trench, that is at least 4 feet(1. 2 m) wide and extends from one exterior wall to the opposite exterior wall...

Français

Domaine(s)
  • Manœuvres d'intervention (incendies)

Espagnol

Conserver la fiche 1

Fiche 2 2020-01-13

Anglais

Subject field(s)
  • Fire-Fighting Techniques
CONT

Firefighters went atop the building and cut a "ventilation trench" along the entire length of the roof, intended to stop the fire from spreading to the rest of the building...

Français

Domaine(s)
  • Manœuvres d'intervention (incendies)
DEF

Tactique défensive où une ouverture de sortie est pratiquée dans le toit d'un bâtiment en feu, d'un mur extérieur à l'autre, pour créer une ouverture qui arrêtera la propagation de l'incendie.

CONT

La fonction de la tranchée de ventilation (aussi appelée bande de ventilation) diffère quelque peu de celle de la ventilation verticale traditionnelle […] La ventilation verticale traditionnelle sert simplement à éliminer la fumée et les gaz surchauffés d'un bâtiment. Elle atteint son efficacité maximale lorsqu'elle est pratiquée directement au-dessus du feu. La tranchée de ventilation sert plutôt à arrêter la propagation d'un incendie dans un bâtiment long et étroit. Elle est effectuée en pratiquant une grande ouverture, ou tranchée, d'au moins 1,2 m (4 pi) de largeur, d'un mur extérieur au mur extérieur opposé […]

Espagnol

Conserver la fiche 2

Fiche 3 2017-07-26

Anglais

Subject field(s)
  • Electrical Appliances and Equipment
  • Fire Safety
CONT

All electrical ventilation systems shall be provided with remote control means for stopping the motors in case of fire or other emergency. For the machinery space ventilation systems there shall be provided two emergency stop stations.... The second emergency stop station shall be located as distant as practicable from the other... "in case of fire trip to stop ventilation. "

OBS

emergency stop station: term officially approved by the Lexicon Project Committee (New Brunswick).

Français

Domaine(s)
  • Appareillage électrique
  • Sécurité incendie
CONT

Les clapets de fermeture [...] sont utilisés comme volets de séparation et d’arrêt dans les systèmes de ventilation industriels ainsi que dans les tunnels et les centrales électriques. [...] Clapet pour poste d'arrêt d'urgence. [...]

OBS

poste d'arrêt d'urgence : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Espagnol

Conserver la fiche 3

Fiche 4 2011-11-21

Anglais

Subject field(s)
  • Roofs (Building Elements)
  • Thermal Insulation
CONT

Super insulated roofs have a thermal resistance rating of R-45 or greater and a vapor retarder on the warm side of the insulation. Generally these systems are not vented or are vented only enough to avoid creating a vapor trap in the attic or roof joist space. A super insulated roof greatly reduces, but does not stop heat escaping the building. In some places, super insulation without ventilation is enough to eliminate chronic icing at eaves.

OBS

insulated roof: term officially approved by the Lexicon Project Committee (New Brunswick).

Français

Domaine(s)
  • Toitures (Éléments du bâtiment)
  • Isolation thermique
CONT

Les résultats de la défaillance de l'isolant sont beaucoup moins évidents que ceux de la défaillance de l'imperméabilisation. Néanmoins, la défaillance de l'isolant entraîne beaucoup plus de dépenses. Par exemple, si la valeur «U» d'un toit isolé est de 0.067 Btu/h pi² F, la perte de chaleur totale annuelle par 100 pi² de surface est d'environ 1,6M Btu (millions de British thermal units).

OBS

toit isolé : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Espagnol

Conserver la fiche 4

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :