TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

VOLUMETRIC SAMPLE [5 fiches]

Fiche 1 2010-06-22

Anglais

Subject field(s)
  • Equipment (Chemistry)
  • Scientific Instruments
CONT

Sampler-dilutor... The calibrated pipet enables the sample volume to be checked against a precise volumetric standard at any time, and re-calibration to any sample volume desired... Insert pipet tip into sample container... ;when yellow "intake complete" light is on, sampling cycle is complete; place container to receive sample and diluent under pipet... ;when the yellow "dispense complete" light is on, dilution is completed.

Terme(s)-clé(s)
  • sampler-diluter

Français

Domaine(s)
  • Équipement (Chimie)
  • Instruments scientifiques
CONT

Échantillonneur-diluteur [...] La pipette étalonnée de façon précise permet de vérifier le volume d'échantillon par comparaison à un étalon et de régler l'étalonnage à un volume d'échantillon désiré [...] Il suffit de placer la pointe de la pipette dans le récipient contenant l'échantillon [...]; lorsque la lampe témoin jaune «intake complete» (prise d'échantillon terminée) s'allume, on place le récipient destiné à recevoir l'échantillon et le diluant sous la pipette [...]; lorsque la lampe jaune «dispense complete» (distribution terminée) s'allume, la dilution est faite.

CONT

L'étude du pipetteur-diluteur est basée sur un mécanisme simple qui met en rapport deux seringues dont les pistons sont commandés par un moteur électrique et dont la course est limitée par des butées interchangeables.

Espagnol

Conserver la fiche 1

Fiche 2 1995-06-05

Anglais

Subject field(s)
  • Environmental Studies and Analyses
  • Air Pollution
  • Occupational Health and Safety
DEF

"High Volume Air Sampler": A filtering device for particulate collection, used by the National Air Pollution Control Administration to determine the concentrations of suspended particulates in American urban and rural areas. A glass-fiber medium is used which can filter at the rate of 70 cubic feet per minute. The filter is over 99 percent efficient for the collection of particles as fine as 0.3 um [micrometers] in diameter. High Volume Air Samplers generally run as long as 24 hours without an appreciable increase in airflow resistance.

DEF

"hi-volume sampler" : A device used to filter air at high volumetric flow rate and collect a sample of particulate matter on a filter.

Français

Domaine(s)
  • Études et analyses environnementales
  • Pollution de l'air
  • Santé et sécurité au travail
CONT

(...) les poussières en suspension dans l'air ont été récoltées à l'aide d'un échantillonneur à grand débit (...)

CONT

(...) appareils de prélèvement à grands débits tels que le "High Volume Sampler" américain (...)

Espagnol

Campo(s) temático(s)
  • Estudios y análisis del medio ambiente
  • Contaminación del aire
  • Salud y seguridad en el trabajo
CONT

El muestreador de grandes volúmenes utiliza un motor de aspersión de alto flujo (1.3 a 1.7 m cúbicos por minuto), el cual succiona la corriente de aire del ambiente y está dispuesto de tal forma que partículas menores a 100µm de diámetro dirigidas y pasadas a través de un filtro de fibra de vidrio que retiene partículas de hasta 0.1µm de diámetro. [...]

CONT

Los muestreadores mecanizados generalmente, colectan muestras de tipo integrado [...] El más común es el muestreador de grandes volúmenes para partículas (Hi-Vol), que colecta las partículas sobre filtros por succión a través de la concentración de partículas suspendidas totales y contaminantes orgánicos e inorgánicos contenidos en las partículas colectadas.

Conserver la fiche 2

Fiche 3 1990-07-03

Anglais

Subject field(s)
  • Cheese and Dairy Products
DEF

A test involving volumetric measurement of the fat content of a sample of milk; sulfuric acid is added, and the flask is heated to liquefy the fat, which is brought to the calibrated neck of the flask by centrifugal force.

Français

Domaine(s)
  • Laiterie, beurrerie et fromagerie

Espagnol

Conserver la fiche 3

Fiche 4 1981-06-05

Anglais

Subject field(s)
  • Concrete Construction
  • Destructive and Non-destructive Tests (Mat.)
CONT

Air Content. The measurement of the amount of air entrained in fresh concrete during placement is essential to maintain the quality desired.... It is desirable to check every batch of ready-mixed concrete on critical construction using a portion of the sample of concrete selected for making strength specimens.... The pressure method... is the commonest and most accurate for all concrete except lightweight, which requires the volumetric method...

Terme(s)-clé(s)
  • entrained air test
  • entrapped air test

Français

Domaine(s)
  • Bétonnage
  • Contrôle destructif et non destructif (Matér.)
CONT

La Technologie des Matériaux (Contrôle, Expertises). Activités : [...] Essais d'affaissement et d'air occlus sur béton plastique.

OBS

La consistance du béton frais est vérifiée au moyen du cône d'affaissement et la teneur en air entraîné est mesurée au moyen de l'appareil à pression. L'air entraîné est un facteur très important pour un béton de revêtement et un volume variant de 5 à 7% est recommandé, dépendant de la grosseur maximum des agrégats. [...] Tous les essais de contrôle tels que consistance, teneur en air entraîné, résistance en flexion et résistance en compression doivent être exécutés suivant les méthodes normalisées et aussi fréquemment qu'exigés par les devis.

Terme(s)-clé(s)
  • essai d'air entraîné
  • essai de teneur en air entraîné
  • essai d'air occlu

Espagnol

Conserver la fiche 4

Fiche 5 1980-10-01

Anglais

Subject field(s)
  • Coal-Derived Fuels
DEF

The moisture in the analysis sample of coal after it has attained approximate equilibrium with the air in the laboratory and removable under standardized conditions, which are defined in ISO Recommendation R 331, Determination of moisture in the analysis sample of coal by the direct gravimetric method, and ISO Recommendation R 348, Determination of moisture in the analysis sample of coal by the direct volumetric method.

Français

Domaine(s)
  • Combustibles dérivés des charbons
DEF

Humidité dans l'échantillon pour analyse du charbon, après qu'elle atteint un équilibre approximatif avec l'air du laboratoire, et susceptible d'être enlevée dans des conditions normalisées, définies dans les Recommandations ISO/R 331, Détermination de l'humidité contenue dans l'échantillon de charbon pour analyse par la méthode gravimétrique directe, et ISO/R 348, Détermination de l'humidité contenue dans l'échantillon de charbon pour analyse par le méthode volumétrique directe.

Espagnol

Conserver la fiche 5

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :