TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

ADSORPTION TUBE [3 fiches]

Fiche 1 2000-07-24

Anglais

Subject field(s)
  • Peace-Keeping Operations
  • Arms Control

Français

Domaine(s)
  • Opérations de maintien de la paix
  • Contrôle des armements
OBS

Reproduit du lexique «Disarmament and Peace Keeping/Désarmement et Maintien de la Paix» avec l'autorisation de l'Office des Nations Unies à Genève.

Espagnol

Conserver la fiche 1

Fiche 2 1996-07-26

Anglais

Subject field(s)
  • Analytical Chemistry
  • Environmental Studies and Analyses
CONT

Gases may be injected by means of a gas-tight syringe or through a special gas inlet chamber of constant volume (gas sampling valve).

CONT

Where a GC [gas chromatograph] is used at a spill site, an automated gas sampling valve may be used. Outside air is injected directly through a 1 cm³ sampling loop by means of a diaphragm pump. This is useful for ongoing monitoring. Alternately, the sample may be drawn through an adsorption tube....

Français

Domaine(s)
  • Chimie analytique
  • Études et analyses environnementales
CONT

Introduction des échantillons. Les chromatographes pour analyses de gaz ... comportent généralement une chambre d'introduction [...]. [...] l'échantillon d'un volume de l'ordre de 1 cm³ [...] peut être prélevé de l'ampoule de prélèvement puis introduit dans la chambre d'introduction à l'aide d'une "seringue d'injection" [...] à piston en polymère fluoré : [...] on pousse rapidement le piston afin que l'introduction du gaz soit instantanée. On préfère utiliser une boucle d'échantillonnage [...] dont le tube en U [...] constitue l'élément essentiel. Le gaz à analyser traverse ce tube [...]. Les vannes à gaz [...], qui peuvent être rotatives ou à piston, fonctionnent sur le même principe; disposées à la place de la chambre d'introduction, elles évitent la dilution de l'échantillon dans le volume de cette chambre qui précède la colonne.

Espagnol

Conserver la fiche 2

Fiche 3 1996-05-13

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Semiconductive Thin Film Detector. Using the known principle that the adsorption and desorption of gases cause a change in electrical conductivity of semiconductors, Seiyama et al. developed a new chromatographic detector for gaseous components.... The current, depending upon the resistance of the film, is converted to voltage by the variable resistance, which is fed without amplification to a recorder. Resistance also adjusts the input voltage of the recorder at desired sensitivity. Using zinc oxide as an example of a typical film material, the conductivity of its film maintains a fixed value when the nitrogen carrier gas is passed at a constant flow rate throught the borosilicate glass tube. When a small amount of another gas or vapor is added to the carrier gas, its conductivity is changed.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :