AMBIENT SOUND LEVEL [3 fiches]

Fiche 1 2000-01-07

Anglais

Subject field(s)
  • Building Insulation and Acoustical Design
  • Acoustics (Physics)
  • Noise Pollution
  • Audio Technology
DEF

Normal sound level present in a space, above which speech, music, or similar specific wanted sound must be presented.

DEF

ambient sound level; background sound level. The sound level that is present in the environment produced by acoustical sources other than the source of interest.

CONT

The amount of acoustical privacy between two spaces is related to the background noise level as well as to the sound isolation provided by the construction.

OBS

ambient sound level; background sound level : terms and definition(h) standardized by the CSA. Material reproduced with the permission of the copyright holder, the Canadian Standards Association(CSA), 178 Rexdale Blvd., Toronto, Ontario, Canada M92 1R3. However, CSA shall not be responsible for the manner in which the information is presented, nor for any interpretations thereof. This CSA material may not have been updated to reflect amendments subsequently made to the original content. For further information, contact CSA.

Français

Domaine(s)
  • Isolation et acoustique architecturale
  • Acoustique (Physique)
  • Pollution par le bruit
  • Électroacoustique
CONT

Un niveau de bruit de fond dans un local est acceptable lorsqu'il n'interfère pas avec les activités pour lesquelles le local est prévu. Dans les grandes salles industrielles, les limites de bruit peuvent être basées sur les niveaux relativement élevés tolérés par les règlements en matière de bruit au travail. À l'autre extrême, dans un studio d'enregistrement, presque tous les bruits audibles sont indésirables. Dans un grand nombre de locaux tels que les salles de classe et les salles de réunion, prévues pour la communication orale, des niveaux de bruit de fond assez bas interféreront avec la précision et la qualité de la communication.

CONT

Rappels d'acoustique et performances du CD [...] Le rapport signal sur bruit : Correspond au rapport entre l'intensité maximale que peut prendre le signal utile et le niveau du bruit de fond (c'est le souffle que l'on entend parfois). Encore une fois avec 90dB on atteint largement les conditions d'un concert classique. Remarques : Le rapport signal sur bruit réel est malheureusement très souvent bien en deçà de la capacité théorique du disque compact. En effet, les ingénieurs du son effectuent souvent un mixage trop travaillé, ne règlent pas correctement le niveau des micros, ou tout simplement enregistrent dans un environnement bruyant.

Espagnol

Conserver la fiche 1

Fiche 2 1986-05-06

Anglais

Subject field(s)
  • Building Insulation and Acoustical Design
  • Anti-pollution Measures
  • Showplaces and Facilities (Performing Arts)
CONT

Studios are entered through pairs of sound-proof doors enclosing an area known as a sound lock. A large sound lock volume again makes a high attenuation easier to achieve and relatively lightweight, sound-proof doors are effective if they lead into a large and highly absorbent sound lock.

CONT

Noise exclusion.... Acoustically lined and filtered air ducts, double-wall construction between studios, sound-lock vestibules, and other sound insulation precautions are usually required to meet the 20-25 dB ambient noise level... generally specified for recording studios.

Français

Domaine(s)
  • Isolation et acoustique architecturale
  • Mesures antipollution
  • Salles et installations de spectacles
DEF

Espace compris entre deux portes étanches aux sons, qui empêche, à l'ouverture d'une porte, les bruits extérieurs de pénétrer dans les studios.

CONT

Protection contre les bruits aériens. - (...) Les portes seront d'excellents qualité, indéformables et appliqueront bien contre les battants, mais il en sera prévu deux en série et, entre elles, une cabine dite sas, de dimensions réduites (1 m x 1 m par exemple et même moins), entièrement revêtue de produits absorbants; (...)

Espagnol

Conserver la fiche 2

Fiche 3 1986-05-06

Anglais

Subject field(s)
  • Building Insulation and Acoustical Design
  • Acoustics (Physics)
  • Noise Pollution
DEF

Random uncontrollable and irreducible noise level at a location or in a valve or circuit.

CONT

Noise exclusion.... Acoustically lined and filtered air ducts, double-wall construction between studios, sound-lock vestibules, and other sound insulation precautions are usually required to meet the 20-25 dB ambient noise level... generally specified for recording studios.

Français

Domaine(s)
  • Isolation et acoustique architecturale
  • Acoustique (Physique)
  • Pollution par le bruit
CONT

La traînée sonore [...] dépend [...] des caractéristiques absorbantes des matériaux se trouvant dans le local. Sa durée dépend aussi du bruit émis par la source avant sa coupure et du niveau du bruit d'ambiance [...]

CONT

Aux États-Unis [...] le système de ventilation ne doit produire aucun bruit de niveau spectral élémentaire supérieur au niveau du bruit ambiant.

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :