TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

BLOWER FAN [39 fiches]

Fiche 1 2020-11-18

Anglais

Subject field(s)
  • Wood Drying
  • Facilities and Equipment (Wood Industries)
DEF

A kiln in which the circulation of air is effected, and ventilation aided, by means of a... fan or blower.

Français

Domaine(s)
  • Séchage du bois
  • Installations et équipement (Industr. du bois)
DEF

Séchoir à bois dans lequel une soufflerie ou un ventilateur assure la circulation d'air et favorise la ventilation.

Espagnol

Conserver la fiche 1

Fiche 2 2017-08-28

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • Building Ventilation
  • HVAC Distribution Systems
  • Computer Hardware
CONT

Blowers are fans that operate where the resistance to gas flow is predominantly downstream of the fan. Exhausters are fans that operate where the flow resistance is mainly upstream of the fan.

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Ventilation (Construction)
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Matériel informatique
DEF

Ventilateur à enveloppe, installé à l'entrée d'un circuit et aspirant le fluide dans une enceinte de grandes dimensions.

OBS

Pour les ventilateurs autres que les ventilateurs brasseurs d'air.

OBS

Suivant l'usage auquel on le destine, un ventilateur peut fonctionner : a) En soufflant, s'il aspire librement l'air extérieur et le refoule dans le local d'utilisation, b) En aspirant, s'il aspire l'air vicié d'une chambre pour le rejeter à l'extérieur.

Espagnol

Campo(s) temático(s)
  • Systemas de enfriamiento y ventilación
  • Ventilación (Construcción)
  • Sist. de calefacción, ventilación y acondicionamiento de aire
  • Equipo físico de computadora (Hardware)
Conserver la fiche 2

Fiche 3 2016-01-21

Anglais

Subject field(s)
  • Machinery
  • Compressors
  • Cooling and Ventilating Systems
CONT

In the centrifugal blower the flow through the machine is essentially radial, whereas in the axial fan the general direction of flow is axial.

Français

Domaine(s)
  • Machines
  • Compresseurs
  • Systèmes de refroidissement et de ventilation
CONT

La soufflante centrifuge (ou radiale) possède un taux de compression par étage supérieur à celui d'une soufflante axiale: elle a une caractéristique pression-débit à faible pente, avec limite de pompage éloignée du régime optimal.

Terme(s)-clé(s)
  • souffleur centrifuge
  • souffleuse centrifuge

Espagnol

Conserver la fiche 3

Fiche 4 2012-11-27

Anglais

Subject field(s)
  • Electric Rotary Machines
  • Machinery

Français

Domaine(s)
  • Machines tournantes électriques
  • Machines
OBS

hélice à pales de ventilateur des moteurs de traction : terme uniformisé par le Canadien Pacifique.

Espagnol

Conserver la fiche 4

Fiche 5 2011-10-25

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
  • Gas and Oil Heating
CONT

Heating by suspended gas heater and roof top unit.

OBS

Unit heaters and other gas-fired air heaters. Unit heaters described here are self-contained, automatically controlled, vented, gas-burning devices designed for the heating of non-residential space. They may be divided into two groups in two ways; first, according to the static pressure against which they will deliver heated air; and second, according to the method of location. Types of unit heaters : Suspended Unit Heaters : Propeller Fan; Blower type(with or without duct) ;Heavy-duty suspended blower. Floor or Platform Mounted Unit Heaters : Vertical blower type; Heavy-duty floor-mounted blowers.

OBS

Suspended blower type unit heaters are used much the same as propeller units. ... Blower units are particularly effective for heating buildings where it is necessary to suspend the units more than 12 ft above the floor. ... Heat distribution ducts may also be attached to the blower type units and several rooms heated by the one unit.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
  • Chauffage au gaz et au mazout
OBS

Les différents types d'aérothermes existants permettant une adaptation aisée aux besoins; ils se divisent en appareils muraux et en appareils suspendus dits "plafonniers" (...)

OBS

"générateur de chaleur" : appareil destiné soit à chauffer directement une pièce ou un local, comme un poêle, un foyer à feu ouvert ou un générateur de chaleur suspendu, soit à chauffer les pièces ou locaux d'un bâtiment au moyen d'un système de chauffage central, tel un générateur d'air chaud ou une chaudière.

OBS

"heater" : "appareil de chauffage".

Espagnol

Conserver la fiche 5

Fiche 6 2011-10-21

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

Central furnace equipped with a fan or blower that provides the primary means for circulation of air.

OBS

Forced-air-type central furnaces are most commonly fired by LP gas, natural gas or oil. They may also operate electrically.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)

Espagnol

Conserver la fiche 6

Fiche 7 2008-03-26

Anglais

Subject field(s)
  • Aeronautical Engineering and Maintenance
PHR

Cooling air, air supply, agent, blower, blower screens, door, duct, fan, fins, flap, rib.

Français

Domaine(s)
  • Aérotechnique et maintenance
OBS

refroidissement : terme uniformisé par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Maintenance.

PHR

Agent, ailettes, air, canalisation d'air, ventilateur, volet de refroidissement.

Espagnol

Conserver la fiche 7

Fiche 8 2008-02-25

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • Combustion and Fuels (Fireplaces)
DEF

A fan or blower that produces a negative pressure in the combustion chamber, causing a suction which draws in air.

CONT

Several sealed direct sidewall venting oil boilers are now available. These are quiet and do not require a draft inducer fan.

OBS

ID induced draft.

Terme(s)-clé(s)
  • draught inducer fan

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Combustion et combustibles (Foyers)
CONT

[...] ventilateur axiaux à tirage induit pour la climatisation et les petits équipements industriels.

Espagnol

Campo(s) temático(s)
  • Systemas de enfriamiento y ventilación
  • Combustión y combustibles (Hogares o chimeneas)
Conserver la fiche 8

Fiche 9 2008-02-22

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • Centrifugal Pumps
DEF

The rotating member of a turbine, blower, fan, axial or centrifugal pump, or mixing apparatus.

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Pompes centrifuges
CONT

La roue est l'élément actif du ventilateur; c'est elle qui apporte l'énergie au fluide véhiculé par le ventilateur. Elle lui fournit cette énergie sous deux formes : en le mettant en vitesse ce qui revient à augmenter sa pression dynamique et en augmentant sa pression statique essentiellement par l'effet de la force centrifuge.

OBS

Le terme «roue à aubes» a été uniformisé par le CUTA - Opérations aériennes.

Terme(s)-clé(s)
  • roue de ventilateur centrifuge
  • roue de ventilateur hélicoïde
  • roue de ventilateur axial

Espagnol

Campo(s) temático(s)
  • Systemas de enfriamiento y ventilación
  • Bombas centrífugas
DEF

Parte giratoria de los motores y los generadores eléctricos.

Conserver la fiche 9

Fiche 10 2007-10-22

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

Any oven heating system in which the products of combustion from the burners are discharged into the oven chamber by a circulating fan or blower, and in which the burners are in a combustion chamber effectively separated from the oven chamber.

OBS

There are 2 types: 1. Nonrecirculating-products of combustion are discharged into the oven chamber and are not returned to the combustion chamber. 2. Recirculating-oven chamber atmosphere is recirculated to the combustion chamber and is in contact with the burner flame.

Terme(s)-clé(s)
  • direct fired external heater

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Générateurs à combustion directe, ils s'utilisent à l'extérieur ou dans les locaux bien ventilés. Fonctionnant indifféremment avec du fioul, du gasoil ou du pétrole, leur mise en marche est instantanée, la chaleur immédiate.

Espagnol

Conserver la fiche 10

Fiche 11 2005-07-20

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
DEF

A gas burner in which combustion air is blown in by a motor driven fan.

CONT

[A] power burner [is a] burner in which the combustion air is supplied by a fan or blower at sufficient pressure to overcome the resistance of the burner and the appliance.

OBS

Power burner [means] a burner in which either gas or air or both are supplied at pressures exceeding, for gas, the line pressure and, for air, atmospheric pressure; this added pressure being applied at the burner. A [power] burner for which air for combustion is supplied by a fan ahead of the appliance is commonly designated as a forced draft burner.

OBS

Forced-draft burner ... commonly called a "power burner".

OBS

"Burners of the power type use a fan to supply and control combustion air". Depending on ASHRAE Handbook & Product Directory, a "power burner" could be of the natural draft (natural-draft power burner) or forced-draft type (forced-draft power burner).

OBS

For gas or oil burner.

Terme(s)-clé(s)
  • forced draught burner
  • forced-draught burner
  • forced draught power burner
  • forced-draught power burner

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

[...] brûleurs à air soufflé. Ces brûleurs comportent un ventilateur assurant un mélange intime du gaz et l'air.

CONT

On peut également classer les brûleurs [à combustibles liquides] suivant le mode d'apport de l'air de combustion. Ils sont dits: - à tirage naturel [...]. - à apport d'air si l'air est amené par des dispositifs mécaniques [...] soit refoulants, soit aspirants. - à tirage forcé si l'air de combustion aspiré par le brûleur met la chambre de combustion du générateur en surpression par rapport à l'atmosphère (foyer surpressé).

CONT

Les [...] brûleurs soufflés, dans lesquels le gaz et l'air sont comprimés par un ventilateur avant d'être éjectés à la buse.

Espagnol

Conserver la fiche 11

Fiche 12 2004-04-16

Anglais

Subject field(s)
  • Solid Fuel Heating
DEF

Any of certain centrifugal devices for separating solid material from gases or liquids ....

CONT

The equipment included in these [storage] systems is as follows : Raw coal feeder, an air-swept pulverizer, an exhauster or blower, a source of hot air or flue gas, piping, a cyclone separator, a dust collector, vent fan, air lock, and transport system.

Français

Domaine(s)
  • Chauffage aux combustibles solides
CONT

Cyclones. Ils sont utilisés dans le cas de chauffe semi-directe ou indirecte afin de séparer le circuit des gaz, qui participent au broyage, du circuit d'air primaire qui transporte le charbon pulvérisé vers le brûleur.

Espagnol

Campo(s) temático(s)
  • Calefacción por combustibles sólidos
DEF

Aparato utilizado para la separación de dos fases, generalmente sólida y fluida, mediante la acción de la fuerza centrífuga.

Conserver la fiche 12

Fiche 13 2003-04-14

Anglais

Subject field(s)
  • Heating
DEF

A warm-air heating... in which positive air circulation is provided by means of a fan or a blower.

Français

Domaine(s)
  • Chauffage
CONT

Chauffage par air chaud pulsé. Ce chauffage diffère du chauffage à air chaud par circulation naturelle en ce que la circulation de l'air est assurée par un ventilateur électrique, dont le degré de silence doit être fonction de la destination des locaux.

CONT

Chauffage par air chaud pulsé. [...] Le générateur peut avoir son foyer propre, fonctionnant au fuel ou au gaz, ou comporter une batterie d'eau chaude ou de vapeur branchée sur une installation centrale.

Espagnol

Campo(s) temático(s)
  • Calefacción
Conserver la fiche 13

Fiche 14 2000-05-25

Anglais

Subject field(s)
  • Gas and Oil Heating
  • Burners and Steamfitting
DEF

A power burner in which gas is supplied at atmospheric pressure(zero gas) maintained by a zero governor. A fan, or blower, blows the air through a venturi, where venturi action pulls the gas into the airstream. The quantity of gas drawn into the airstream is a direct function of the air velocity, so the air-fuel ratio will remain constant regardless of the air volume. The firing rate is controlled by air adjustment alone.

Français

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fumisterie et brûleurs
OBS

Voir la fiche «régulateur atmosphérique / zero governor».

Espagnol

Conserver la fiche 14

Fiche 15 2000-05-25

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Combustion and Fuels (Fireplaces)
DEF

The pressure difference, created by machinery such as a fan or blower, sufficient to supply all, or part of, the required combustion air into the combustion chamber.

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Combustion et combustibles (Foyers)

Espagnol

Conserver la fiche 15

Fiche 16 2000-05-25

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

The motor which drives the blower or fan that delivers air at proper velocity into the combustion chamber.

Français

Domaine(s)
  • Fumisterie et brûleurs
OBS

Les brûleurs à pulvérisation par l'air peuvent être construits pour fonctionner en basse, moyenne ou haute pression, donc en trois gammes correspondant chacune à une machine caractéristique qui est : Un ventilateur centrifuge tant que la pression est inférieure à 0,1 bar, mais le plus souvent comprise entre 0,03 et 0,06 bar [...] parce que la machine ne comporte alors qu'un seul étage lorsqu'elle est directement accouplée à un moteur électrique tournant à 2 800 tr/mn.

Espagnol

Conserver la fiche 16

Fiche 17 2000-04-28

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

A period of time after the run period during which the burner motor(blower or fan) continues to run, driving all the products of combustion and any unburned fuel from the combustion chamber, and supplying air to burn fuel being purged from the fuel line downstream from the safety shutoff valve.

CONT

When the burner is shut off for any reason, the program controller causes the forced draft fan to continue delivering air for a specified time to post-purge the unit of any atomized oil and combustible gases. This post-purge should amount to at least two air changes in the combustion area, gas passages, and breeching.

Français

Domaine(s)
  • Fumisterie et brûleurs
CONT

Les traits communs des systèmes de régulation de grandes chaudières à gaz ou à fuel sont : le système de sécurité de fermeture [...], la vérification de l'allumage électrique avant démarrage, la pré-purge pour évacuer les gaz non brûlés de la chambre de combustion avant démarrage, la post-purge pour exécuter la même opération après l'arrêt et l'allumage à faible intensité [...]

Espagnol

Conserver la fiche 17

Fiche 18 2000-04-28

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

A gas burner in which the gas and air are mixed before they are introduced into the combustion chamber. Usually, the gas and air are both fed into a fan or blower, and the mixture is then blown into the combustion chamber. A premix burner burns with a short, hot flame with high heat release. Examples are Mechanical-premix, Fanmix, and Zero-Governor Burners.

CONT

In a premix burner, gas and primary air are mixed together, and the mixture is then introduced into secondary air in the combustion zone.

Terme(s)-clé(s)
  • pre-mix burner

Français

Domaine(s)
  • Fumisterie et brûleurs
DEF

Brûleur dans lequel le gaz combustible, le gaz comburant et l'aérosol sont mélangés avant le front de flamme.

CONT

Pour mettre en présence, lors de la combustion, le gaz et l'air, deux techniques peuvent être utilisées, ce qui permet une classification des brûleurs: - brûleurs sans mélange préalable de l'air et du gaz [...] - brûleurs avec mélange préalable de l'air et du gaz; le gaz est mélangé avant son admission dans le foyer avec une partie ou la totalité de l'air nécessaire à sa combustion complète; si la quantité d'air mélangée au gaz (aération primaire) est insuffisante pour assurer une combustion complète de gaz, il faut prévoir au niveau de la flamme une alimentation d'air (aération secondaire) qui permette d'achever la combustion du gaz.

CONT

2.3 Brûleurs à prémélange. 2.31 Brûleurs à prémélange air-gaz sous pression. [...] 2.32 Brûleurs à prémélange à gaz seul sous pression.

Espagnol

Conserver la fiche 18

Fiche 19 2000-03-31

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

A power burner in which a fan, or blower, blows air at high velocity past turbulators. The gas, at regulated pressure, is released into the turbulent airstream-typically from a ring at the mouth of the burner(in which case it is also called a ring burner). The gas escapes through orifices around the periphery of the ring. Gas and air are adjusted simultaneously to maintain the proper air-fuel ratio as the firing rate changes. In high-pressure gun burners, the gas is ejected at pressures up to 15 psi from spuds located in the center of the turbulent airstream instead of at the outside.

Français

Domaine(s)
  • Fumisterie et brûleurs

Espagnol

Conserver la fiche 19

Fiche 20 2000-03-31

Anglais

Subject field(s)
  • Burners and Steamfitting
CONT

gun type burner. A power burner in which a fan, or blower, blows air at high velocity past turbulators. The gas, at regulated pressure, is released into the turbulent airstream-typically from a ring at the mouth of the burner(in which case it is also called a ring burner). The gas escapes through orifices around the periphery of the ring. Gas and air are adjusted simultaneously to maintain the proper air-fuel ratio as the firing rate changes. In high-pressure gun burners, the gas is ejected at pressures up to 15 psi from spuds located in the center of the turbulent airstream instead of at the outside.

Français

Domaine(s)
  • Fumisterie et brûleurs
OBS

gun burner / brûleur à air total.

Espagnol

Conserver la fiche 20

Fiche 21 2000-02-28

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • Burners and Steamfitting
DEF

A fan or blower that blows air into the combustion chamber.

CONT

Forced-draft fan does not open until air selector on Bailey Board is set at 15%... (CFB Ottawa, CHP SOP’s)

Terme(s)-clé(s)
  • forced-draught fan
  • forced draught fan

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Fumisterie et brûleurs
OBS

Il existe deux types principaux de brûleur à gaz : le brûleur atmosphérique qui est un brûleur sans ventilateur et dans lequel l'air nécessaire à la combustion est aspiré par la simple ascension des gaz brûlés et le brûleur à air soufflé dans lequel l'apport de l'air comburant s'effectue au moyen d'un ventilateur [...]

Espagnol

Conserver la fiche 21

Fiche 22 2000-02-28

Anglais

Subject field(s)
  • Combustion and Fuels (Fireplaces)
  • Burners and Steamfitting
DEF

Combustion air introduced over the burner flame to enhance completeness of combustion.

CONT

In the dutch oven configuration, fuel is introduced through the roof of the dutch oven and forms a conical pile which burns on the surface and around the edges. Primary preheated over fire air is admitted above the pile, with secondary air introduced in the furnace area to burn volatiles driven off in the dutch oven area.

CONT

The introduction of air from a blower or fan into the combustion chamber after the oil has left the [burner] nozzle is referred to as secondary air.

Français

Domaine(s)
  • Combustion et combustibles (Foyers)
  • Fumisterie et brûleurs
DEF

Air amené au-dessus de la zone de combustion pour enflammer l'oxyde de carbone produit.

CONT

L'air primaire comprend la totalité de l'air entrant dans le four par le brûleur. Dans le cas particulier d'un four moderne de cimenterie, l'air primaire représente de 8 à 12 % de l'air total. Il permet une combustion immédiate mais partielle du combustible, et l'accrochage de la flamme. En faisant varier le débit et la pression d'injection, on modifie la forme de la flamme. Dans le cas d'une chauffe au charbon, une partie de l'air primaire peut servir au transport de celui-ci. L'air introduit ultérieurement dans le four pour assurer la combustion totale est appelé, selon les configurations industrielles particulières, air secondaire, air tertiaire...

Espagnol

Conserver la fiche 22

Fiche 23 1999-10-27

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • HVAC Distribution Systems
  • Building Ventilation
DEF

A fan which withdraws air from a localized area, such as a toilet, from which it must not return to the central air-treatment system.

CONT

Blowing vs. exhausting.... In the case of a fan with duct connections at both inlet and outlet the performance curve will be substantially the same whether the fan is operating as a blower or exhauster.

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Ventilation (Construction)
CONT

Suivant la position du ventilateur sur ce réseau [de transport d'air], le ventilateur est dit introducteur, extracteur ou recycleur; [...] un extracteur d'air reprend l'air du local et l'évacue à l'extérieur du local [...]

CONT

Cette expulsion [de l'air vicié] peut être obtenue naturellement [...], mais on la réalise le plus souvent à l'aide de ventilateurs aspirants appliqués à la paroi, sur le toit, ou au moyen d'installations centralisées d'aspiration.

OBS

Le terme «ventilateur-aérateur» semble être un spécifique. Il ne figure d'ailleurs plus dans LAROG 1982, qui a succédé à LGRAN 1960.

Terme(s)-clé(s)
  • ventilateur d'aspiration

Espagnol

Conserver la fiche 23

Fiche 24 1990-10-02

Anglais

Subject field(s)
  • Burners and Steamfitting
DEF

A period of time after burner startup(call for heat) during which the burner motor(blower or fan) runs to change the air of the combustion chamber and breeching prior to ignition trials. This removes any unburned fuel so only the incoming fuel will be present for ignition.

CONT

The programmer controls the sequence of operation as follows: 1. Starts the burner fan so that the furnace, or combustion space, the gas passages of the heat exchanger, and the breeching are purged of any unburned combustible gases. This flow of air is maintained until the entire volume of combustion space, gas passages, and breeching has been changed at least several times. it is commonly called prepurge.

Français

Domaine(s)
  • Fumisterie et brûleurs
CONT

Les traits communs des systèmes de régulation de grandes chaudières à gaz ou à fuel sont : le système de sécurité de fermeture [...], la vérification de l'allumage électrique avant démarrage, la pré-purge pour évacuer les gaz non brûlés de la chambre de combustion avant démarrage, la post-purge [...] et l'allumage à faible intensité [...]

CONT

Certains brûleurs réalisent le prébalayage, c'est-à-dire un effet de soufflerie qui précède l'allumage des électrodes et qui a pour effet de chasser les gaz détonants (mélange de gaz rémanents et imbrûlés qui n'auraient pas fait l'objet d'une combustion parfaite) La période de prébalayage (quelques secondes) peut se confondre avec la période de pré-allumage qui correspond à la mise sous tension du transformateur d'allumage.

Espagnol

Conserver la fiche 24

Fiche 25 1990-03-27

Anglais

Subject field(s)
  • Heating
DEF

A warm-air heating system in which positive air circulation is provided by means of a fan or a blower.

DEF

Heating system in which air, circulated mechanically by either a blower or fan, is the transfer medium.

Français

Domaine(s)
  • Chauffage
CONT

Dans le système de chauffage à air pulsé, la circulation d'air est assurée par un ventilateur électrique.

CONT

Installation de chauffage à air chaud pulsé. Dans de telles installations, l'air réchauffé, soit directement dans un appareil de production d'air chaud à foyer propre (générateur d'air chaud), soit au contact d'une batterie de chauffe (aérotherme) est pulsé par un ventilateur ou turbine à travers un réseau de gaines et conduit jusqu'aux locaux à chauffer dans lesquels il est distribué par des bouches de soufflage.

Espagnol

Conserver la fiche 25

Fiche 26 1987-09-30

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • HVAC Distribution Systems
OBS

propeller fan : An axial-flow blower, with or without a casing, using a propeller-type rotor to accelerate the fluid.

OBS

Propeller fan, Axial flow fan: A fan in which air enters and leaves the impeller in a direction substantially parallel to its axis.

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Ventilateur hélicoïde, ventilateur axial : Ventilateur dans lequel l'air entre dans la roue et en sort suivant une direction sensiblement parallèle à l'axe.

OBS

On distingue les ventilateurs hélicoïdes [...] dans lesquels l'air ne change pas de direction dans la traversée de l'appareil des ventilateurs centrifuges dans lesquels l'air change de direction et est rejeté radialement [...]

Espagnol

Conserver la fiche 26

Fiche 27 1986-11-05

Anglais

Subject field(s)
  • Aircraft Systems
CONT

The radio rack cooling fan is installed in the forward end of the left utility tunnel, in a section of ducting that bypasses the radio rack cooling overboard exhaust ducting. ... The fan is used to create a flow of cooling air through the electrical and electronic equipment installations when the airplane is on the ground. The fan is also used to direct radio rack cooling exhaust air beneath the forward lower cargo compartment floor, to maintain temperature above freezing in the cargo compartment. The fan is an axial-flow type powered by a 115-volt, 400-cycle, 3-phase electric motor.

CONT

During normal operation, airflow is produced by a radio rack blower, located in the air conditioning compartment below the radio rack. The blower is a single stage axial flow fan, driven by a three phase 200 volt electrical motor, powered by No. 1 AC bus.

Français

Domaine(s)
  • Circuits des aéronefs
OBS

Le terme "ventilateur baie radio" a été uniformisé par le CUTA opérations aériennes et accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Espagnol

Conserver la fiche 27

Fiche 28 1985-12-06

Anglais

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
CONT

Fuel-burning appliances that incorporate an electric blower to provide air supply for combustion(for example, pressure-type oil burners) are usually able to counteract the negative pressure induced by a normal exhaust fan.

Terme(s)-clé(s)
  • pressure oil burner

Français

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout

Espagnol

Conserver la fiche 28

Fiche 29 1985-10-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Forced Air Wood Furnaces. Central wood-burning furnaces are controlled by a wall mounted thermostat in the living area. Temperature and fan controls are the same as those found on oil and gas furnaces. Unlike room heaters, which produce a steady heat output by periodic manual adjustments of the draft control, most wood furnaces operate in cycles. A cycle starts with the thermostat sensing that heat is needed in the room where it is located. It signals the furnace control system which opens the combustion air damper and a hot fire develops. When the air inside the furnace's sheet metal casing gets hot, a preset fan control starts the circulating blower and the warm air is moved through the ducts to all areas of the house.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)

Espagnol

Conserver la fiche 29

Fiche 30 1985-10-30

Anglais

Subject field(s)
  • Types of Hearths (Heating)
DEF

... prefabricated shells used as liners for masonry fireplaces. They are of double wall construction to allow air movement between panels. This movement picks up heat that might otherwise be lost up the chimney. Natural convection of room air through this cavity can be supplemented with a blower fan.

Français

Domaine(s)
  • Types de foyers (Chauffage)

Espagnol

Conserver la fiche 30

Fiche 31 1985-10-01

Anglais

Subject field(s)
  • Rehabilitation (Medicine)
  • Medical and Surgical Equipment
OBS

It is a system that changes sound into light, using your lamps. You see the sounds you do not hear.... You can choose the exact sound you want to know about.... For example, two small children in different rooms, or a telephone and a door buzzer, or an alarm clock and an oven timer. For those with vision and hearing problems, a fan, blower, or vibrator can be substituted for a lamp.

OBS

These information were obtained from the publicity brochure for Opticear, published by the Canadian Hearing Society.

Français

Domaine(s)
  • Réadaptation (Médecine)
  • Équipement médico-chirurgical

Espagnol

Conserver la fiche 31

Fiche 32 1982-12-23

Anglais

Subject field(s)
  • Electric Motors
CONT

The vast majority of small shaft-mounted fan and blower motors utilize the air from the fan to cool the motor. They are generally of a totally enclosed construction, and are usually split-phase or capacitor start and run motors up to about 500 W. Small shaded-pole motors are also common. Three-phase cage motors are used above about 100 W.

Terme(s)-clé(s)
  • 3-phase cage motor

Français

Domaine(s)
  • Moteurs électriques

Espagnol

Conserver la fiche 32

Fiche 33 1981-09-22

Anglais

Subject field(s)
  • Gas and Oil Heating
OBS

Typical gas furnace : Lowboy model, the blower fan is placed behind rather than below the combustion section.

Français

Domaine(s)
  • Chauffage au gaz et au mazout

Espagnol

Conserver la fiche 33

Fiche 34 1981-09-22

Anglais

Subject field(s)
  • Gas and Oil Heating
OBS

Typical gas furnace : Highboy model, the blower fan is placed below rather than behind the combustion section.

Français

Domaine(s)
  • Chauffage au gaz et au mazout

Espagnol

Conserver la fiche 34

Fiche 35 1981-01-31

Anglais

Subject field(s)
  • Machinery
  • Mechanics
OBS

(...) used in place of the standard radiator grill. Lowers direct blower fan dust upward. In tandem pushing, it protects the forward operator from fan blown dust and heat.

Terme(s)-clé(s)
  • blast suppressor

Français

Domaine(s)
  • Machines
  • Mécanique
OBS

Se monte à la place de la grille de radiateur. Les lamelles dirigent le souffle vers le haut, ce qui lors de la poussée en tandem, protège le conducteur du premier pousseur contre la chaleur et la poussière chassées par le ventilateur.

Espagnol

Conserver la fiche 35

Fiche 36 1981-01-26

Anglais

Subject field(s)
  • Cooling and Ventilating Systems
  • Equipment and Tools (Water Supply)
CONT

Water is drawn into the vacuum chamber by an electric blower unit or a centrifugal fan used as a vacuum pump, operating regularly.

Français

Domaine(s)
  • Systèmes de refroidissement et de ventilation
  • Équipement et outillage (Alimentation en eau)
CONT

L'aspiration dans la cloche s'effectue à l'aide d'un groupe électro-surpresseur ou d'un ventilateur centrifuge travaillant en pompe à vide, fonctionnant d'une manière régulière.

Espagnol

Conserver la fiche 36

Fiche 37 1981-01-26

Anglais

Subject field(s)
  • Wastewater Treatment
CONT

Pulsation frequency is connected with the setting of the suction flow into the chamber; the latter is adjusted by partial opening of an air leak valve in the suction circuit where a blower is used or by simply throttling the suction line in the case of a fan.

Français

Domaine(s)
  • Traitement des eaux usées
CONT

La fréquence des pulsations est liée au réglage du débit aspiré dans la cloche; il s'effectue par ouverture partielle d'une vanne de fuite d'air sur le circuit d'aspiration dans le cas d'utilisation d'un surpresseur, ou par simple vannage sur la tuyauterie d'aspiration dans le cas d'un ventilateur.

Espagnol

Conserver la fiche 37

Fiche 38 1981-01-26

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
CONT

Pulsation frequency is connected with the setting of the suction flow into the chamber; the latter is adjusted by partial opening of an air leak valve in the suction circuit where a blower is used or by simply throttling the suction line in the case of a fan.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
CONT

La fréquence des pulsations est liée au réglage du débit aspiré dans la cloche; il s'effectue par ouverture partielle d'une vanne de fuite d'air sur le circuit d'aspiration dans le cas d'utilisation d'un surpresseur, ou par simple vannage sur la tuyauterie d'aspiration dans le cas d'un ventilateur.

Espagnol

Conserver la fiche 38

Fiche 39 1976-06-19

Anglais

Subject field(s)
  • Air Transport
CONT

"See that the blower fan operate smoothly and quietly".

Français

Domaine(s)
  • Transport aérien
CONT

S'assurer que les ventilateurs fonctionnent régulièrement et silencieusement

Espagnol

Conserver la fiche 39

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :