TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

CCD DETECTOR [7 fiches]

Fiche 1 2009-09-09

Anglais

Subject field(s)
  • Measuring Instruments (Engineering)
  • Nuclear Physics
CONT

For a detector without gain(such as a CCD camera), or for photoncounting detectors, G1/41 and F1/41. The gain will depend on the camera model and can usually be adjusted experimentally, whereas the excess noise factor depends on the amplification technology and the actual gain...

Français

Domaine(s)
  • Instruments de mesure (Ingénierie)
  • Physique nucléaire
CONT

Les principes de la détection directe et indirecte sont représentés par les voies 1 et 2. Quant aux voies A et B, elles correspondent aux détecteurs sans gain et avec gain, respectivement. On voit que la détection neutronique nécessite l'utilisation d'une étape préliminaire.

Espagnol

Conserver la fiche 1

Fiche 2 2007-01-31

Anglais

Subject field(s)
  • Radar, Radio Guidance and Goniometry
  • Spacecraft
  • Remote Sensing
CONT

[The] push-broom scanner [is a] type of imaging system... commonly used in optical remote sensing satellites such as SPOT. The imaging system has a linear detector array(usually of the CCD type) consisting of a number of detector elements(6000 elements in SPOT HRV). Each detector element projects an "instantaneous field of view(IFOV) "on the ground. The signal recorded by a detector element is proportional to the total radiation collected within its IFOV. At any instant, a row of pixels are formed. As the detector array flies along its track, the row of pixels sweeps along to generate a two-dimensional image.

OBS

linear detector array: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

Français

Domaine(s)
  • Radar, radioguidage et radiogoniométrie
  • Engins spatiaux
  • Télédétection
CONT

La mission d'observation est réalisée par un instrument à barrette CCD [charged-coupled device] de type «push-broom» avec une visée au nadir : sous l'effet du défilement du satellite sur son orbite, une barrette de détecteurs carrés disposés en ligne acquiert successivement les différentes lignes permettant de reconstituer une image. La taille de chaque détecteur élémentaire et la période d'échantillonnage sont ajustées de telle manière qu'en une période d'échantillonnage le point subsatellite se déplace de la projection au sol d'un détecteur au nadir.

OBS

barrette de détecteurs : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

PHR

Capteur à barrette de détecteurs.

Espagnol

Campo(s) temático(s)
  • Guía radárica, radioguía y radiogoniometría
  • Naves espaciales
  • Teledetección
Conserver la fiche 2

Fiche 3 2004-08-06

Anglais

Subject field(s)
  • Facilities and Instruments (Astronomy)
DEF

A telescope which uses liquid as a reflecting surface. The liquid is spun at a rate which causes it to become a perfect parabolic surface.

CONT

Liquid mirror telescopes cannot be tilted and hence cannot track like conventional telescopes do. To track with imagery, narrow-band filter spectrophotometry or slitless spectroscopy, one can use a technique, called time delayed integration(TDI) also known as drift scan, that uses a CCD detector that tracks by electronically stepping its pixels.

Français

Domaine(s)
  • Installations et instruments (Astronomie)
CONT

Les télescopes à miroir liquide : Le procédé repose sur un principe simple. Pour réfléchir et concentrer les rayons lumineux en un point, le miroir d'un télescope traditionnel doit être parfaitement parabolique. Or, la surface d'un liquide prend naturellement la forme d'une parabole lorsqu'on le fait tourner sur lui-même [...] le mercure, liquide à température ambiante, réfléchit très bien la lumière.

CONT

Les avantages des télescopes à miroir liquide (TML) sont bien connus : facilité de réalisation, très faible coût, même pour un diamètre considérable, et excellentes qualités optiques. Leur inconvénient majeur est, bien sûr, qu'ils ne peuvent «pointer» que la verticale où ils sont installés. [...] Les détecteurs CCD en mode «drift-scan» permettent de «suivre» le déplacement apparent des sources et d'intégrer leur lumière pendant un temps de pose significatif. Ces poses, cumulées sur un certain nombre de nuits, permettent l'observation de «bandes» de ciel avec une profondeur en magnitude apparente tout à fait comparable à celle des observations pointées en imagerie sur un télescope moderne.

Espagnol

Conserver la fiche 3

Fiche 4 2004-03-18

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Separation of spectral and non-spectral interferences by on-line high performance ion chromatography inductively coupled plasma sector field mass spectrometry (HPIC-ICP-SFMS) for accurate determination of234U,235U,238U and232Th in industrial ores.

CONT

Determination of trace elements in human milk by inductively coupled plasma sector field mass spectrometry (ICP-SFMS).

CONT

Indiana University Laboratory for Spectrochemistry. Plasma Source Mass Spectrometry. "Single-Crystal Scintillator-Based Array Detector for Sector-Field Mass Spectrometry, "[by] David A. Solyom. Beginning with the use of photographic plates in the first quarter of this century, array detectors have had a long history of usage in mass-spectrometric analysis. Array detectors are position-sensitive devices capable of independently measuring ion signals that are incident at different locations on the detector's face. Currently popular among the different types of array detectors available for mass spectrometry are microchannel-plate(s)(MCP) coupled with a phosphor.... The electrons emitted from the rear of the MCP strike the phosphor being held in close proximity(1mm) to the MCP. The phosphor screen is sensitive to the incident electrons and will emit photons in response. The number of emitted photons is proportional to the number of incident electrons and the location on the phosphor from which the photons are emitted coincides with the location of the incident electrons. The photons from the phosphor can then be converted into a proportional electronic signal by an imaging device such as a CCD or CID detector array.

Français

Domaine(s)
  • Chimie analytique
CONT

spectrométrie de masse à secteurs à plasma induit (ICP-SFMS).

OBS

Il existe plusieurs traductions du terme «inductively coupled plasma (ICP)» : le plus proche de la description de la technique est «plasma induit par un courant de haute fréquence», le plus simple est «torche à plasma»; pour décrire un «sector field mass spectrometer» nous parlons de «spectromètre de masse à secteur magnétique» ou, plus brièvement, de «spectromètre de masse magnétique». L'équivalent français de ICP-SFMS serait donc «torche à plasma couplée à un spectromètre de masse magnétique» (version courte) ou «plasma induit par un courant de haute fréquence associé à un spectromètre de masse à secteur magnétique» (version longue). [Source : Guy Bouchoux, Secrétaire, Société française de spectrométrie de masse, École Polytechnique, DCMR, Palaiseau (France)]

Espagnol

Conserver la fiche 4

Fiche 5 2003-03-26

Anglais

Subject field(s)
  • Satellite Telecommunications
  • Spacecraft
CONT

The main units of the AIC are : the focal plane assembly(FPA), equipped with a back-thinned illuminated CCD matrix and a front-end amplifier, provides the optical signal detection. A thermoelectric peltier cooler under the detector sets the operating point at-25°C ± 100 mK, the detection box(BD) which supplies the FPA with the necessary electrical signals to operate the CCD. It generates the clock waveforms from the VEU signals and filters the supplied voltage from the DSU, the video electronics unit(VEU) which processes the analog signal coming from the FPA, digitizes it on 12 bits before passing it on in serial processing to the science data processing subsystem(SDPSS). It also provides the DBs with the primary clock signal. The power conditioning of the VEU is located in the same unit, the detection supply unit(DSU) delivers relevant stabilized voltages to the 5 DUs and power to thermo-coolers from the main supply feeder of the instrument.

OBS

Converter sub-assembly.

Français

Domaine(s)
  • Télécommunications par satellite
  • Engins spatiaux

Espagnol

Conserver la fiche 5

Fiche 6 2002-12-10

Anglais

Subject field(s)
  • Scientific Instruments
  • Scientific Measurements and Analyses
  • Astrophysics and Cosmography
CONT

The Star Imager instrument measures satellite attitude based on an onboard star catalogue. It contains a Charge Coupled Detector(CCD) camera. [This instrument is] optically aligned, so magnetic field vectors can be measured directly without distortion from movements in the mechanical structure of the satellite.

Français

Domaine(s)
  • Instruments scientifiques
  • Mesures et analyse (Sciences)
  • Astrophysique et cosmographie
OBS

Un des quatre instruments du projet de satellite Orsted (Danemark) [...] pour déterminer l'orientation absolue pour le magnétomètre à grille de flux à bobine sphérique.

Espagnol

Conserver la fiche 6

Fiche 7 1992-10-17

Anglais

Subject field(s)
  • Telecommunications
  • Electrical Engineering

Français

Domaine(s)
  • Télécommunications
  • Électrotechnique

Espagnol

Conserver la fiche 7

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :