GRAVITY PIPING [13 fiches]

Fiche 1 2016-05-04

Anglais

Subject field(s)
  • Pipes and Fittings
  • HVAC Distribution Systems
  • Heating
CONT

The Hartford loop is a special arrangement of return piping at the boiler. Its purpose is to reduce the likelihood of an insignificant quantity of water creating a low water condition that can cause damage to a steam heating boiler. It came into general use in 1919 and was primarily designed for use with heating systems having gravity wet return. In effect, it consists of two loops of pipe forming two U-tubes. The first loop is around the boiler and the second loop is composed of the drip connection, the wet return, and a short riser called the loop riser.... The use of a Hartford loop is not recommended where the condensate is returned to the boiler by a condensate pump.

Français

Domaine(s)
  • Tuyauterie et raccords
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Chauffage
CONT

La boucle de Hartford est une configuration conçue comme un des dispositifs destinés à empêcher la vidange accidentelle de la chaudière.

Espagnol

Conserver la fiche 1

Fiche 2 2011-09-27

Anglais

Subject field(s)
  • Sewers and Drainage
  • Plumbing
CONT

Piping that is too low to drain into a building sewer by gravity shall be drained to a sump or receiving tank.

OBS

receiving tank: term officially approved by the Lexicon Project Committee (New Brunswick).

Français

Domaine(s)
  • Égouts et drainage
  • Plomberie
CONT

La tuyauterie dont le niveau ne permet pas l'écoulement par gravité dans un branchement d'égout doit être raccordée à un puisard ou à un réservoir de captage.

OBS

réservoir de captage : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Espagnol

Conserver la fiche 2

Fiche 3 2010-06-10

Anglais

Subject field(s)
  • Heating
CONT

In the supercooled clouds, the condensed water converted into snow crystals can reach the mountain surface without evaporating.

CONT

The steam heating system conveys steam through pipes to heat exchangers, such as radiators, convectors, baseboard units, radiant panels, fan-driven heaters, and returns the resulting condensed water to the boiler. Such systems normally operate at pressure not exceeding 15 pounds per square inch gage(psig) or 103 kPa gage, and in many designs the condensed steam returns in the boiler by gravity because of the static head of water in the return piping.

Français

Domaine(s)
  • Chauffage
CONT

[Chauffage à vapeur basse pression.] Les canalisations, que l'on peut classer en deux types : -l'aller qui lie le générateur aux corps de chauffe; cette canalisation est remplie de vapeur; de l'eau de condensation, du fait du refroidissement d'une partie de la vapeur, est véhiculée dans la même canalisation; -le retour : cette canalisation permet le retour de l'eau de condensation à la chaudière [...]

Espagnol

Conserver la fiche 3

Fiche 4 - données d’organisme externe 2006-01-24

Anglais

Subject field(s)
  • Waste Management
  • Nuclear Waste Materials
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
OBS

The collection system consists of piping from the collection points, drained by gravity into a collection tank.

Français

Domaine(s)
  • Gestion des déchets
  • Déchets nucléaires
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
OBS

Le circuit de collecte est constitué de conduites raccordées aux points de collecte, et le liquide est drainé par gravité vers un réservoir de collecte.

Espagnol

Conserver la fiche 4

Fiche 5 - données d’organisme externe 2005-08-18

Anglais

Subject field(s)
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

The collection system consists of piping from the collection points, drained by gravity into a collection tank.

Français

Domaine(s)
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le circuit de collecte est constitué de conduites raccordées aux points de collecte, et le liquide est drainé par gravité vers un réservoir de collecte.

Espagnol

Conserver la fiche 5

Fiche 6 2004-08-04

Anglais

Subject field(s)
  • Oil Production
CONT

The development of SAGD [steam-assisted gravity drainage] is... a major innovation... other innovations include... control and measurement of steam flow in distribution piping...

Français

Domaine(s)
  • Production pétrolière
CONT

La mise au point de la SGSIV [séparation gravitaire stimulée par injection de vapeur] représente [...] une innovation cruciale. [...] Autres innovations : [...] contrôle et mesure du débit de vapeur dans la canalisation de distribution [...]

Espagnol

Conserver la fiche 6

Fiche 7 2001-06-15

Anglais

Subject field(s)
  • Equipment and Tools (Water Supply)
  • Water Treatment (Water Supply)
  • Wastewater Treatment
CONT

The design of gravity rapid sand filters shall be based on a maximum design filtration rate of two gallons per square foot per minute. As the beginning of filter runs for declining rate filters, a maximum filtration rate of three gallons per square foot per minute is allowed. The filter discharge piping shall be designed with an orifice or other permanently installed flow limiting device to ensure that the maximum filter rate cannot be exceeded... With the exception of declining rate filters, each filter unit shall be equipped with a manually adjustable rate-of-flow indication or control valves with indicators.

Français

Domaine(s)
  • Équipement et outillage (Alimentation en eau)
  • Traitement des eaux
  • Traitement des eaux usées
CONT

[...] réalisation, dans certains cas, soit de filtres à vitesse décroissante (double filtration, filtres, dual media filter), soit de filtres à granulométries différentes.

Espagnol

Conserver la fiche 7

Fiche 8 1993-05-10

Anglais

Subject field(s)
  • Papermaking Machines
CONT

The operating principle of pressure screens is similar to gravity centrifugal screens. The distinction is that they operate under full line pressure and the radial flow within the unit can be either centrifugal(outward), centripetal(inward) or a combination depending on design. They have the advantage of high capacity per unit, flexibility of physical location, small space requirements and economy of piping and pumping. The totally enclosed design excludes air entrainment and minimizes slime buildup.

CONT

Pressure screens were first used in paper machine approach systems where their main function was to remove gross contaminants and protect the papier machine forming fabric. More recently, with refinements and modifications in design, various configurations are being utilized in virtually all fine screening applications.

Français

Domaine(s)
  • Machines à papier
DEF

Type de classeur fonctionnant sous pression, par opposition aux modèles fonctionnant à la pression atmosphérique.

Espagnol

Conserver la fiche 8

Fiche 9 1993-04-28

Anglais

Subject field(s)
  • Pipes and Fittings
OBS

Figure.

Français

Domaine(s)
  • Tuyauterie et raccords

Espagnol

Conserver la fiche 9

Fiche 10 1990-01-30

Anglais

Subject field(s)
  • Heating
DEF

A heating system in which one pipe is used for supplying steam to radiator and another pipe is used to return cooled water or condensate to boiler.

CONT

Two-pipe steam heating systems... are designed to operate at pressures ranging from subatmospheric(vacuum) to high pressure. Although they use many practical piping arrangements to provide up-flow or down-flow systems, they are conveniently classified by the method of condensate return to the boiler. Condensate can be returned to the boiler by gravity or by use of any one of several mechanical return means.

Français

Domaine(s)
  • Chauffage
OBS

(...) les installations de chauffage à vapeur (...) Le système de chauffage à deux tuyaux (...) comporte deux tuyaux, dont un d'amenée pour la vapeur, et l'autre de retour, plus petit, pour l'eau de condensation.

Espagnol

Conserver la fiche 10

Fiche 11 1990-01-29

Anglais

Subject field(s)
  • Heating
CONT

The steam heating system conveys steam through pipes to heat exchangers, such as radiators, convectors, baseboard units, radiant panels, or fan-driven heaters, and returns the resulting condensed water to the boiler. Such systems normally operate at pressure not exceeding 15 pounds per square inch gage(psig) or 103 kPa gage, and in many designs the condensed steam returns to the boiler by gravity because of the static head of water in the return piping.

OBS

condensed: reduced from gaseous to liquid state.

Français

Domaine(s)
  • Chauffage
CONT

[Chauffage à vapeur]. Dans le système avec trappes de retour, on utilise alors des trappes sur chaque radiateur ou convecteur; une trappe permet le passage de l'air et de la vapeur condensée et prévient le passage de la vapeur. Ainsi, la vapeur entre dans le radiateur, et aussitôt qu'elle se condense, elle passe par la trappe pour arriver dans le tuyau de retour.

Espagnol

Conserver la fiche 11

Fiche 12 1990-01-29

Anglais

Subject field(s)
  • Pumps
  • Heating
CONT

Condensate return pumps are used for low pressure, gravity return heating system. They are normally of the motor driven centrifugal type and have a receiver and automatic float control. Other types of condensate return pumps are the rotary, screw, turbine and reciprocating pump. ... the condensate pump has a capacity of 2.5 to 3 times normal flow.

CONT

When the steam condensate cannot be returned by gravity to the boiler in a two-pipe [steam heating] system, an alternating return lifting trap, condensate return pump, or vacuum return pump must be used to force the condensate back into the boiler. In a condensate return pump arrangement, the return piping is arranged for the water to flow by gravity into a collecting receiver or tank, which may be located below the steam-boiler waterline.

CONT

When ... the condensate cannot be returned to the boiler by gravity ... a condensate pump [is used] ... A condensate pump must be located at the low point of return and as close to the boiler as possible.

Français

Domaine(s)
  • Pompes
  • Chauffage
CONT

Dans une telle installation, quand l'eau condensée ne peut retourner par gravité dans le générateur de vapeur, on emploie une pompe refoulante ou une pompe à vide de retour de l'eau condensée, pour introduire celle-ci sous pression dans le générateur. Dans les installations à pompe de retour de l'eau de condensation, la tuyauterie de retour est dimensionnée de manière à ce que l'eau s'écoule par gravité dans le collecteur de retour ou dans la bâche recueillant le produit de condensation

Espagnol

Conserver la fiche 12

Fiche 13 1990-01-29

Anglais

Subject field(s)
  • Heating
CONT

A gravity system without circulating pumps is rarely installed. It depends on a difference in density of the hot supply water [or hot air] and the colder return water [or air] for working head. Airflow resistance must be kept to a minimum, and the circulating piping system must be of large size.

Français

Domaine(s)
  • Chauffage
CONT

Le système par gravité, (...) part du principe que l'eau chaude, étant rendue plus légère par la dilatation, tend à s'élever.

CONT

Dans le système par gravité, c'est la densité de l'air qui crée la circulation. L'air chaud qui laisse la fournaise pour se diriger dans les conduites d'amenée étant d'une densité moindre que l'air froid arrivant sur le réchaud, il se dirige, en s'élevant, vers les registres.

Espagnol

Conserver la fiche 13

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :