TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

HALON FIRE SUPPRESSION [14 fiches]

Fiche 1 2013-12-13

Anglais

Subject field(s)
  • Security Devices
  • Armour
DEF

The automatic fire and explosion suppression system that consists of 1 set of fixed extinguishers containing FE-25 gas for the engine compartment, 3 sets of extinguishers containing halon in the crew compartment.

Français

Domaine(s)
  • Dispositifs de sécurité
  • Arme blindée
DEF

Système [qui] comprend 1 ensemble d'extincteurs fixes dans le compartiment moteur qui contiennent du FE-25 et 3 extincteurs dans le compartiment d'équipage qui contiennent du gaz halon.

Espagnol

Conserver la fiche 1

Fiche 2 2011-07-11

Anglais

Subject field(s)
  • Trade Names
  • Extinguishing Agents
CONT

Inergen is a blend of three naturally occurring gases: Nitrogen, Argon, and Carbon Dioxide.

OBS

Inergen is an environmentally green three dimensional fire suppression agent replacing Halon 1301. Critical facilities such as data processing rooms, telecommunications switching facilities, process control rooms, and others, require a non-water based extinguishing agent that : Is electrically nonconductive [;] Is safe for use in human occupied facilities[;] Would not damage sensitive electronic equipment[;] Has zero ozone depletion, zero global warming, and zero atmospheric lifetime...

OBS

Inergen®: A trademark of Tyco Fire Products LP.

Terme(s)-clé(s)
  • Inergen

Français

Domaine(s)
  • Appellations commerciales
  • Agents extincteurs
CONT

[...] les mélanges de gaz inertes dont l'innocuité et l'efficacité ont été prouvées : l'INERGEN (mélanges d'azote, d'argon et de dioxyde de carbone) ou l'ARGONITE (mélange d'azote et d'argon) [sont] utilisés en installation fixe dans des espaces occupés, quand l'utilisation d'un gaz est souhaitée et que le stockage d'un volume important est possible. L'émission de ces gaz ne doit pas abaisser la concentration d'oxygène à moins de 12% en volume; dans ce cas l'exposition des personnes doit être évitée dans toute la mesure du possible - soit par une évacuation préalable - soit par le port d'un équipement (type adduction d'air par exemple) pour les personnes appelées à intervenir, notamment pour porter secours.

OBS

Inergen® : Marque de commerce de la société Tyco Fire Products LP.

Terme(s)-clé(s)
  • Inergen

Espagnol

Conserver la fiche 2

Fiche 3 2010-02-10

Anglais

Subject field(s)
  • Fire-Fighting and Rescue Equipment
CONT

... it is not practical to rely on halon gas as the sole means of automatic fire suppression. If halon gas is still considered, it should be provided as a first line of defence only, and should be supported by other means of automatic suppression such as a sprinkler system.

OBS

Suppression: The total work of extinguishing a fire beginning with its discovery.

Français

Domaine(s)
  • Matériel de secours et de lutte (incendies)
CONT

[...] il n'est pas pratique de compter sur le gaz halon comme unique moyen d'extinction automatique des incendies. [...] [Il] devrait être utilisé conjointement avec d'autres moyens d'extinction automatique comme les extincteurs à eau.

OBS

Installation d'extinction: Ensemble des moyens d'extinction, d'alimentation et d'attaque destiné à projeter ou déverser un agent extincteur sur un foyer d'incendie. On distingue les installations fixes et les installations mobiles. (...) Ces installations peuvent être automatiques, semi-automatiques ou manuelles.

Espagnol

Conserver la fiche 3

Fiche 4 2010-02-10

Anglais

Subject field(s)
  • Fixed Rescue Facilities (fire)
DEF

A permanently piped system using a limited stored supply of a Halon gas under pressure, and discharge nozzles to totally flood an enclosed area. Released automatically, by a suitable detection system. Extinguishes fires by inhibiting the chemical reaction of fuel and oxygen.

Français

Domaine(s)
  • Installations fixes de secours (incendies)
CONT

Principe de fonctionnement d'un système d'extinction par halon 1301. Les fonctions ou groupes de fonctions que doit (ou peut) assurer un système d'extinction automatique par halon 1301 (I.E.A.H.) sont [les suivantes] : [...] détection et sollicitation de l'I.E.A.H.; signalisation d'évacuation; répartition [...]; retardement de l'émission; ouverture des conteneurs; distribution; [...] émission.

OBS

[I.E.A.H.]: Les lettres I-E-A signifient «installation d'extinction automatique» (générique) alors que le H signifie «halon».

OBS

Total flooding/noyage total (saturation): Action de remplir un volume avec un agent extincteur (gaz, mousse à haut foisonnement) afin de permettre l'extinction du feu à l'intérieur de ce volume.

OBS

Total flooding extinguishing system/système d'extinction par protection d'ambiance (par saturation) : Système fixe d'extinction pour l'extinction des feux dans une enceinte fermée.

OBS

Installations fixes d'extinction par hydrocarbures halogénés. Les halogénés ou halons sont des composés chimiquement définis, dérivés d'un hydrocarbure [méthane ou éthane] et contenant des halogènes: fluor, chlore, brome ou iode.

OBS

Noter que le terme «installation» peut se substituer au terme «système» dans toutes les vedettes ci-dessus.

Espagnol

Conserver la fiche 4

Fiche 5 2010-02-10

Anglais

Subject field(s)
  • Fixed Rescue Facilities (fire)
CONT

... let us look at automatic suppression systems.... Automatic fire suppression is dependent on two main elements to be effective,(1) the fire must be detected,(2) sufficient suppressant must be applied. Although a variety of automatic fire suppression systems are available, only two systems are acceptable for occupied areas. Halon 1301 total flooding systems, and automatic sprinkler systems.

CONT

Automatic sprinkler protection and other automatic fire suppression and detection systems can influence choices in building construction.

OBS

Suppression: the total work of extinguish a fire beginning with its discovery.

Français

Domaine(s)
  • Installations fixes de secours (incendies)
CONT

[...] installations d'extinction automatiques [...] Deux conditions doivent être remplies pour que cette méthode soit efficace : 1) l'incendie doit évidemment être détecté; et 2) un produit d'extinction doit être appliqué en quantité suffisante. Bien qu'une variété d'installations automatiques d'extinction d'incendie soit disponible, seulement deux sont acceptables pour des bâtiments occupés. Il s'agit des systèmes d'extinction au halon 1301 et des extincteurs automatiques à eau.

OBS

Fire suppression/extinction des incendies; suppression des incendies. Tout le travail qui consiste à éteindre un incendie après sa détection.

Espagnol

Conserver la fiche 5

Fiche 6 2010-02-10

Anglais

Subject field(s)
  • Security
CONT

Considering the possibility of halon failure, how ever remote it may be, I find halon gas is acceptable as a means to protect collections only as a first line of defence, and must be supported by other means of automatic suppression [of fire] such as a sprinkler system.

OBS

Suppression: The total work of extinguishing a fire beginning with its discovery.

Français

Domaine(s)
  • Sécurité
CONT

Installation fixe d'extinction automatique : Installation fixe d'extinction dont le déclenchement et le fonctionnement ne nécessitent pas une intervention humaine.

CONT

La figure 5 indique les principaux éléments de l'extinction automatique. Deux conditions doivent être remplies pour que cette méthode soit efficace : 1) l'incendie doit évidemment être détecté; et 2) un produit d'extinction doit être appliqué en quantité suffisante.

OBS

Suppression/extinction : Ensemble des opérations destinées à combattre le feu jusqu'à sa disparition.

Espagnol

Conserver la fiche 6

Fiche 7 2010-02-09

Anglais

Subject field(s)
  • Extinguishing Agents
DEF

Period during which the extinguishing medium shall surround the hazard to ensure extinction.

CONT

While control of fire with Halon 1301 is effective, the success or failure of the agent is dependent upon several factors having to work perfectly. If a door is left open, if a fire damper fails to close properly, and/or if the ventilation system fails to shut down, halon gas will dissipate, and suppression may not be successful. Also, the recommended soaking time(deemed necessary for adequate Halon 1301 extinguishment) may be compromised by personnel when opening a door too early....

OBS

holding time: term and definition standardized by ISO.

Français

Domaine(s)
  • Agents extincteurs
DEF

Durée pendant laquelle l'agent extincteur doit rester au niveau du foyer pour assurer l'extinction.

CONT

Utilisation des systèmes au halon 1301. Les systèmes de protection d'ambiance (noyage total) peuvent être utilisés lorsque le risque est localisé dans une enceinte définie qui permet d'établir la concentration requise et de maintenir la concentration minimale d'extinction pendant la durée demandée (compte tenu en particulier du temps d'imprégnation demandé) et ainsi d'assurer efficacement l'extinction.

OBS

temps d'imprégnation : terme et définition normalisés par l'ISO.

Espagnol

Conserver la fiche 7

Fiche 8 2010-02-09

Anglais

Subject field(s)
  • Fire-Fighting and Rescue Equipment
CONT

Considering the limited uses and drawbacks of halon total flooding systems, it is not practical to rely on halon gas as the sole means of automatic fire suppression. If halon gas is still considered, it should be provided as a first line of defence only, and should be supported by other means of automatic suppression such as a sprinkler system.

Français

Domaine(s)
  • Matériel de secours et de lutte (incendies)
CONT

[...] il n'est pas pratique de compter sur le gaz halon comme unique moyen d'extinction automatique des incendies. Si l'on envisage de continuer de l'utiliser, il ne devrait l'être qu'en tant que moyen de défense de première intervention et devrait être utilisé conjointement avec d'autres moyens d'extinction automatique comme les extincteurs à eau.

Espagnol

Conserver la fiche 8

Fiche 9 2010-02-09

Anglais

Subject field(s)
  • Fire Safety
  • Extinguishing Agents
CONT

While control of fire with Halon 1301 is effective, the success or failure of the agent is dependent upon several factors having to work perfectly. If a door is left open, if a fire damper fails to close properly, and/or if the ventilation system fails to shut down, halon gas will dissipate, and suppression may not be successful. Also, the recommended soaking time(deemed necessary for adequate Halon 1301 extinguishment) may be compromised by personnel when opening a door too early....

Français

Domaine(s)
  • Sécurité incendie
  • Agents extincteurs
CONT

Utilisation des systèmes au Halon 1301. Les systèmes de protection d'ambiance (noyage total) peuvent être utilisés lorsque le risque est localisé dans une enceinte définie qui permet d'établir la concentration requise et de maintenir la concentration minimale d'extinction pendant la durée demandée (compte tenu en particulier du temps d'imprégnation demandé) et ainsi d'assurer efficacement l'extinction.

Espagnol

Conserver la fiche 9

Fiche 10 2005-10-25

Anglais

Subject field(s)
  • Fire Safety
CONT

Generally, halon fire suppression systems are elaborate automated systems designed to protect special facilities.

Français

Domaine(s)
  • Sécurité incendie
CONT

En général, les systèmes d'extinction aux halons sont complexes, automatisés, conçus pour protéger des installations spéciales.

Espagnol

Conserver la fiche 10

Fiche 11 2001-08-30

Anglais

Subject field(s)
  • Environmental Management
CONT

The owner of a facility in which a halon fire suppression system is installed assumes responsibility for the complete life cycle management of the halons, from purchase and acceptance on site to final disposal and destruction.

CONT

For the purpose of reducing or phasing out the export of hazardous waste or prescribed non-hazardous waste for final disposal, the Minister may require an exporter ... to (a) submit to the Minister ... a plan ... [Canadian Environmental Protection Act]

Français

Domaine(s)
  • Gestion environnementale
CONT

Le propriétaire de l'installation dans laquelle on a installé un système d'extinction aux halons assume la responsabilité de tout le cycle de vie des halons, de leur achat et de leur réception jusqu'à leur élimination finale et à leur destruction.

CONT

En vue de la réduction ou de la suppression des exportations de déchets dangereux ou de déchets non dangereux visés par règlement destinés à l'élimination définitive, le ministre peut enjoindre à tout exportateur [...] de lui remettre [...] un plan conforme au règlement [...] [Loi canadienne sur la protection de l'environnement]

Espagnol

Conserver la fiche 11

Fiche 12 2000-03-21

Anglais

Subject field(s)
  • Environmental Management
CONT

The owner of a facility in which a halon fire suppression system is installed assumes responsibility for the complete life cycle management of the halons, from purchase and acceptance on site to final disposal and destruction.

Français

Domaine(s)
  • Gestion environnementale
CONT

Le propriétaire de l'installation dans laquelle on a installé un système d'extinction aux halons assume la responsabilité de tout le cycle de vie des halons, de leur achat et de leur réception jusqu'à leur élimination finale et à leur destruction.

Espagnol

Conserver la fiche 12

Fiche 13 2000-03-21

Anglais

Subject field(s)
  • Environmental Management
CONT

Periodic leak testing must be part of the schedule for routine operation and maintenance of all halon fire suppression systems. The management plan may include a review of the rationale for a fully automated system. Fully automated systems are subject to failure and the accidental dumping of a full charge of halon fire suppressant, which would result in a severe release of ozone-depleting halons.

Français

Domaine(s)
  • Gestion environnementale
CONT

Le contrôle périodique des fuites doit faire partie du programme de fonctionnement et d'entretien courant de tous les systèmes d'extinction aux halons. Une partie du plan de gestion peut concerner l'examen de la « justification » donnée pour un système totalement automatisé. Ce système est exposé à des défaillances et à l'évacuation accidentelle de la charge complète d'halons, ce qui pourrait aboutir à un rejet considérable d'halons destructeurs d'ozone.

Espagnol

Conserver la fiche 13

Fiche 14 1988-09-12

Anglais

Subject field(s)
  • Extinguishing Agents

Français

Domaine(s)
  • Agents extincteurs

Espagnol

Conserver la fiche 14

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :