TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

INJECTED FIELD [11 fiches]

Fiche 1 2018-03-29

Anglais

Subject field(s)
  • Veterinary Medicine
DEF

A test used in the field diagnosis of bovine tuberculosis. A small volume of tuberculin is injected intradermally, commonly in a tail fold, and observed at 72 to 96 hours for a significant increase in thickness of the skin. The tuberculin elicits a cell-mediated immune reaction at the site of injection in infected animals and the increased thickness of the skin is the consequence of infiltration into the site of T lymphocytes and macrophages.

Terme(s)-clé(s)
  • SID
  • S.I.D.

Français

Domaine(s)
  • Médecine vétérinaire
CONT

Intradermo-tuberculination simple ou unique (I.D.1). [...] L'importance de la pénétration de la totalité de la dose et son injection strictement intradermique obligent à injecter sans aucune évasion de liquide : une intervention convenable n'est obtenue qu'avec un matériel adapté et en laissant l'aiguille en place le temps nécessaire à l'infiltration totale de la tuberculine dans le derme. La lecture est faite dans les quelques heures qui suivent la 72e heure qui suit l'injection. L'animal est considéré comme tuberculeux si l'on observe des signes cliniques d'ordre inflammatoire, tels que œdème, exsudation, nécrose, douleur, ou réaction inflammatoire des vaisseaux et des ganglions lymphatiques de la région.

OBS

Épreuve de diagnostic.

Espagnol

Campo(s) temático(s)
  • Medicina veterinaria
DEF

[Prueba en donde] se aplica 0.1 ml de PPD [derivado proteico puro] bovino de forma intradérmica en el pliegue anocaudal o en la unión mucocutánea del pliegue vulvar.

CONT

Intradermotuberculinización simple: Comporta una única inyección de tuberculina bovina.

OBS

Se debe realizar una lectura a las 72 hrs después de haber aplicado la tuberculina [...] comparando manualmente el pliegue antes y después de la aplicación, considerando positivo cualquier indicio de inflamación: aumento de tamaño, rubor calor o dolor.

Conserver la fiche 1

Fiche 2 2016-11-23

Anglais

Subject field(s)
  • Nuclear Physics
  • Thermonuclear fusion
DEF

Method in the field of controlled fusion, in which high energy molecular ions are injected into a suitable magnetic container and are dissociated therein by any of several processes(for example collision with neutral atoms, Lorentz dissociation, etc.).

OBS

molecular ion injection: term and definition standardized by ISO.

OBS

Molecular ion injection [is not] widely used [compared to] neutral beam injection ...

OBS

molecular ion injection: term extracted from the “Glossaire de l’énergie nucléaire” and reproduced with permission of the Organisation for Economic Co-operation and Development.

Français

Domaine(s)
  • Physique nucléaire
  • Fusion thermonucléaire
DEF

Méthode du domaine de la fusion contrôlée consistant à injecter des ions moléculaires de grande énergie dans un conteneur magnétique approprié où ils sont dissociés par un processus quelconque (par exemple collision avec des atomes neutres, dissociation de Lorentz, etc.).

OBS

injection d'ions moléculaires : terme et définition normalisés par l'ISO.

OBS

injection d'ions moléculaires : terme extrait du «Glossaire de l’énergie nucléaire» et reproduit avec l’autorisation de l’Organisation de coopération et de développement économiques.

Espagnol

Conserver la fiche 2

Fiche 3 2016-03-08

Anglais

Subject field(s)
  • Oil Production
DEF

A two-step enhanced oil recovery process in which a surfactant slug is injected into the well followed by a larger slug of water containing a high-molecular-weight polymer which pushes the chemicals through the field and improves mobility and sweep efficiency.

Terme(s)-clé(s)
  • micellar flood

Français

Domaine(s)
  • Production pétrolière
CONT

[...] les microémulsions utilisées sont composées de 4 à 80 % de pétrole [...], de 10 à 90 % de saumure [...] et de mélanges de sulfonates ou autres tensioactifs (5 à 15 %) et d'alcools (5 %). On injecte dans le gisement une quantité de microémulsions correspondant à 5 à 10 % du volume des pores de la zone à traiter; [...] on ne pousse pas la microémulsion par de l'eau [...] mais par un volumineux bouchon de polymères en solution [...] L'injection de microémulsion suivie de polymères [...] est le dernier né des procédés de récupération assistée du pétrole; [...]

OBS

La revue Journal of Petroleum Technology utilisée comme source (octobre 1983) porte par erreur le no 10 qui est celui du mois de septembre.

Espagnol

Conserver la fiche 3

Fiche 4 2015-02-25

Anglais

Subject field(s)
  • Theoretical Astronomy
  • Astrophysics and Cosmography
  • The Stars (Astronomy)
CONT

The energy of the relativistic particles of the radio sources is so great that it must also have a gravitational origin. This must be in the same gas cloud that, earlier, powered the field and through which the field lines pass, as otherwise the particles would not be injected into the field.... Furthermore, the particle acceleration mechanism must be electromagnetic rather than by stellar explosions.... A model which appears to satisfy the requirements is the magnetic rotator or spinning plasma cloud with an oblique or orthogonal magnetic field.

Français

Domaine(s)
  • Astronomie théorique
  • Astrophysique et cosmographie
  • Étoiles (Astronomie)
CONT

Comment la nature a-t-elle «construit» un rotateur capable d'inonder si longtemps l'Univers de flots d'énergie tellement puissants [...]? L'axe du champ magnétique du rotateur-magnétoïde ne coïncide pas avec son axe de rotation (ils forment un certain angle) [...]. Pénétrant dans la zone du rayonnement du dipôle magnétique de la super-étoile, [le plasma] devient accéléré jusqu'à des vitesse proches de celle de la lumière et, freiné dans le champ magnétique, commence à émettre des ondes électromagnétiques d'une puissance fantastique.

Terme(s)-clé(s)
  • rotateur magnétique

Espagnol

Conserver la fiche 4

Fiche 5 2013-01-15

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Mass spectrometers consist of several components, an inlet system for introducing the sample, an ionization source for creating ions, a variable magnetic and/or electric field for separating ions based upon on their mass to charge ratio, and an ion detector. The inlet system can be as simple as a port through which the sample is injected or inserted into a chamber at high vacuum and heated to achieve vaporization.

Français

Domaine(s)
  • Chimie analytique
CONT

Un spectromètre de masse comporte essentiellement : un système d'introduction de l'échantillon étudié; une source où l'échantillon est ionisé [...]; l'analyseur [...] un collecteur [...]

Espagnol

Conserver la fiche 5

Fiche 6 2010-11-26

Anglais

Subject field(s)
  • Scientific Instruments
  • Atomic Physics
DEF

[An] electron energy analyzer [using] an electric field to divert [different amounts of] electrons … depending on their kinetic energies.

CONT

A CHA … consists of two metal hemispheres. One hemisphere being shaped concave, and the other convex. They are arranged such that their centres of curvature are coincident … Different voltages are placed on each hemisphere such that there is an electric field between the two hemispheres. Electrons are injected into the gap between the hemispheres. If the electrons are travelling very fast, they will impinge on the outer hemisphere. If they are travelling very slow, they will be attracted to the inner hemisphere. Hence only electrons in a narrow energy region(called the pass energy) succeed in getting all the way round the hemispheres to the detector.

Français

Domaine(s)
  • Instruments scientifiques
  • Physique atomique
DEF

Analyseur d’électrons utilisant un champ électrique pour détourner des électrons de quantités variables en fonction de leur énergie cinétique.

CONT

[Analyseurs d’électrons.] Les analyseurs de type CHA ont des points conjugués à l’entrée et à la sortie des hémisphères mais une optique électronique intercalée entre l’échantillon et l’entrée de l’analyseur donne une plus grande latitude pour le positionnement de l’échantillon. De plus, cette optique permet de choisir l’énergie de passage E des électrons dans l’analyseur et d’opérer ainsi à énergie de passage constante pour toutes les raies du spectre Auger […]

OBS

CHA : concentric hemispherical analyzer.

Espagnol

Conserver la fiche 6

Fiche 7 2009-11-10

Anglais

Subject field(s)
  • Atomic Physics
  • Thermonuclear fusion
  • Nuclear Fission Reactors
CONT

Particles with high kinetic energy that are injected into the plasma transfer their energy to the plasma particles through collisions and heat them. In a neutral particle injector first the ions are produced in an ion source and then accelerated by an electric field. To allow the fast ions to penetrate into the plasma without hindrance from the magnetic field cage, first they have to be re-neutralised. The neutralised particles shoot into the plasma and transfer their energy to the plasma particles through collisions.

Français

Domaine(s)
  • Physique atomique
  • Fusion thermonucléaire
  • Réacteurs nucléaires de fission
CONT

Chauffage par neutres. On vient de voir un mécanisme de chauffage où l'énergie est initialement portée par les électrons du plasma. On peut aussi utiliser des ions énergétiques. Une difficulté apparaît ici : des ions créés à l'extérieur de la configuration magnétique ne peuvent y pénétrer, car ils sont fortement déviés par le champ magnétique. Le procédé est alors le suivant : - on génère des ions avec une source d'ions; - on accélère ces ions jusqu'à l'énergie convenable (de l'ordre de 100 à 200 keV); - on neutralise les ions énergétiques dans une cellule à gaz; - à la sortie de cette cellule et après tri des particules indésirables (particules non neutralisées, etc.), on dispose d'un faisceau de particules neutres et énergétiques qui peuvent alors se propager dans le champ magnétique sans déviation; - arrivées au sein du plasma chaud, ces particules vont s'ioniser comme toutes les particules du plasma : elles sont, de ce fait, piégées dans la configuration magnétique; - les particules ainsi piégées abandonnent progressivement leur énergie en faveur du milieu qui voit ainsi sa température augmenter.

Espagnol

Conserver la fiche 7

Fiche 8 2004-07-13

Anglais

Subject field(s)
  • Oil Production
CONT

Each of the following is designated as an oil and gas facility ... a compressor station ... a dehydrator ... a gas injection station ...

OBS

gas injection : A reservoir maintenance or secondary recovery method that uses injected gas to supplement the pressure in an oil reservoir or field. In most cases, a field will incorporate a planned distribution of gas-injection wells to maintain reservoir pressure and effect an efficient sweep of recoverable liquids.

Français

Domaine(s)
  • Production pétrolière
CONT

Pour l'application de la Loi, chacun des éléments énumérés [...] constitue une installation de production de pétrole et de gaz [...] une station de compression [...] un déshydrateur [...] une station d'injection de gaz [...]

Espagnol

Conserver la fiche 8

Fiche 9 1990-11-22

Anglais

Subject field(s)
  • Atomic Physics
CONT

Considerable development work has been undertaken to perfect a practical superconducting structure for heavy ions. To be attractive, it should have a small diameter, high accelerating field, and low frequency.... Superconducting linacs will probably be used as postaccelerators injected by a large tandem Van de Graaff accelerator.

Français

Domaine(s)
  • Physique atomique
CONT

Les progrès de la technologie des métaux ou alliages supraconducteurs ont permis de construire des grands aimants supraconducteurs dans lesquels règnent des champs magnétiques statiques intenses supérieurs à 4 ou 5 teslas avec une consommation nulle d'électricité (...) Des travaux ont été consacrés à la fabrication des cavités d'accélérateurs linéaires supraconducteurs, d'abord pour des électrons, puis pour des protons et des ions. Des réalisations existent, en particulier des post-accélérateurs disposés derrière des tandems électrostatiques (...)

Espagnol

Conserver la fiche 9

Fiche 10 1989-02-13

Anglais

Subject field(s)
  • Lasers and Masers
OBS

Lasers with injected fields.

Français

Domaine(s)
  • Masers et lasers

Espagnol

Conserver la fiche 10

Fiche 11 1988-05-10

Anglais

Subject field(s)
  • Air Pollution
  • Environmental Studies and Analyses
CONT

At each interval, anthropogenic sulphur dioxide is injected into the parcel. The amount injected is determined by the parcel' s position in the emission field....

Français

Domaine(s)
  • Pollution de l'air
  • Études et analyses environnementales

Espagnol

Conserver la fiche 11

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :