MANUAL ISOLATION VALVE [5 fiches]

Fiche 1 2014-08-22

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Nuclear Fission Reactors
DEF

A valve in the piping that penetrates the reactor containment, whose purpose is to shut off the containment system from the said piping.

CONT

Systems directly connected to [the] heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

OBS

isolation valve: term and definition standardized by ISO in 1997.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Réacteurs nucléaires de fission
DEF

Vanne sur la tuyauterie traversant l'enceinte de confinement d'un réacteur, dont le rôle est d'isoler le système de confinement de ladite tuyauterie.

CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

OBS

vanne d'isolement : terme et définition normalisés par l'ISO en 1997.

Espagnol

Conserver la fiche 1

Fiche 2 - données d’organisme externe 2008-11-19

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire

Espagnol

Campo(s) temático(s)
  • Obturadores y boquillas (Componentes mecánicos)
  • Tuberías y accesorios
  • Centrales nucleares
  • Compartimiento - Comisión Canadiense de Seguridad Nuclear
Conserver la fiche 2

Fiche 3 - données d’organisme externe 1994-10-18

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Piping systems shall be provided with isolation devices having redundancy, reliability, and performance capabilities which reflect the importance to safety of isolating the various types of piping systems penetrating containment.... In order for a manual isolation valve to be considered closed, it shall be either locked closed or continuously monitored to show that the valve is in the closed position.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Pour qu'une vanne d'isolement manuelle soit considérée comme fermée, il faut qu'elle soit verrouillée ou qu'il soit possible de vérifier continuellement qu'elle est fermée.

Espagnol

Conserver la fiche 3

Fiche 4 - données d’organisme externe 1994-10-18

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

Espagnol

Conserver la fiche 4

Fiche 5 - données d’organisme externe 1994-10-18

Anglais

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Systems directly connected to heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve(for instance, a check valve) or a powered isolation valve operable from the control room.

Français

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

Espagnol

Conserver la fiche 5

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :