TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

NULL SIGNAL [15 fiches]

Fiche 1 2010-07-23

Anglais

Subject field(s)
  • Applications of Electronics
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
CONT

The single-axis inertial platform... The angular motions of the controlled member are sensed by the single-axis gyro. The output signal of the gyro is electronically processed and fed to the torque motor(TM) of the stable element and to the torque generator(TG) of the gyro. The problem is to determine how to do the electronic processing so that the controlled member maintains its orientation in spite of disturbances. The voltage across the output signal generator(SG) of the gyroscope is proportional to the integral of the angular velocity of the controlled member about the gyroscope's input axis. Consequently, this signal is fed to an amplifier and then to a motor, which drives the controlled member in the proper direction to null the ouptut of the gyroscope.

OBS

signal generator: A source of electrical signals, whose characteristics, e.g. waveform, frequency, voltage, etc. can be fixed or controlled within specified limits.

Terme(s)-clé(s)
  • output SG

Français

Domaine(s)
  • Applications de l'électronique
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
OBS

générateur de signaux : Source de signaux électriques dont les caractéristiques (forme d'onde, fréquence, tension, etc.) peuvent être réglées à des valeurs fixes, ou à des valeurs variables dans des limites spécifiées.

Espagnol

Conserver la fiche 1

Fiche 2 2004-02-17

Anglais

Subject field(s)
  • Mechanical Transmission Systems
DEF

The change of input signal required to produce a reversal in valve output at null expressed as a percentage of rated signal.

Français

Domaine(s)
  • Transmissions mécaniques
DEF

Variation du signal d'entrée nécessaire pour produire une inversion de la grandeur de sortie de l'appareil en position zéro exprimée en pourcentage du signal nominal.

Espagnol

Campo(s) temático(s)
  • Sistemas de transmisión mecánica
Conserver la fiche 2

Fiche 3 2003-11-21

Anglais

Subject field(s)
  • General Mechanics (Physics)
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
DEF

The axis of rotation of the [gyro] rotor.

CONT

A gyroscope has three sensitive axes of interest. These are(1) spin reference axis,(2) input axis(IA), and(3) output axis(OA). The spin reference axis is the position of the spin axis at its null position as indicated by a pickoff null signal.

CONT

Gyroscope ... The wheel is found to precess slowly, not about the axis of the applied torque, but instead about an axis perpendicular to it (and also perpendicular to the spin axle).

Français

Domaine(s)
  • Mécanique générale (Physique)
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Les Gyroscopes. Ce sont des appareils capables de mesurer la vitesse de rotation absolue de Chandra selon deux axes différents, et dont le fonctionnement repose sur l'utilisation d'une toupie gyroscopique; celle-ci, animée d'une vitesse de rotation élevée (plusieurs milliers de tours par minute), possède une «rigidité inertielle» qui la maintient selon une direction fixe : si l'on applique un couple (une force qui tend à mettre un solide en rotation) sur l'axe de rotation de la toupie, celle-ci s'écarte beaucoup moins vite de sa direction initiale que si elle n'était pas animée d'un mouvement de rotation élevée (c'est d'ailleurs pour cette raison de stabilité que les balles des armes à feu sortent du canon en rotation.).

CONT

Un gyroscope à 1 axe [...] comprend essentiellement : un boîtier B [...]; un anneau de cardan C [...] relié à B par un axe de cardan S appelé axe de sortie [...]; cet axe peut être matérialisé par un arbre de torsion, par des roulements à billes de haute qualité, par des ensembles pivot-pierre, par un palier hydrostatique; une toupie T reliée à C par un axe [delta] appelé axe de spin [...], perpendiculaire à S [...]; un moteur électrique d'entraînement de la toupie; [...] un détecteur d'écart [...]; un moteur-couple [...] cet appareil présente une sensibilité particulière aux rotations de son boîtier autour de l'axe E, perpendiculaire à S et à [delta], appelé, pour cette raison, axe d'entrée [...].

Espagnol

Campo(s) temático(s)
  • Mecánica general (Física)
  • Pilotaje y navegación aérea
  • Instrumentos de navegación
  • Instrumentos y equipo de vuelo (Industria aeronáutica)
Conserver la fiche 3

Fiche 4 2001-08-20

Anglais

Subject field(s)
  • General Mechanics (Physics)
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
DEF

An axis normal to the input reference axis and nominally parallel to the spin axis when the gyro output has a specified value, usually null.

CONT

A gyroscope has three sensitive axes of interest. These are(1) spin reference axis(SRA),(2) input axis(IA), and(3) output axis(OA). The spin reference axis is the position of the spin axis at its null position as indicated by a pickoff null signal.

Français

Domaine(s)
  • Mécanique générale (Physique)
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
OBS

Les gyroscopes. Ce sont des appareils capables de mesurer la vitesse de rotation absolue de Chandra selon deux axes différents, et dont le fonctionnement repose sur l'utilisation d'une toupie gyroscopique; celle-ci, animée d'une vitesse de rotation élevée (plusieurs milliers de tours par minute), possède une «rigidité inertielle» qui la maintient selon une direction fixe : si l'on applique un couple (une force qui tend à mettre un solide en rotation) sur l'axe de rotation de la toupie, celle-ci s'écarte beaucoup moins vite de sa direction initiale que si elle n'était pas animée d'un mouvement de rotation élevée [...] La direction de l'axe de rotation de la toupie représente en fait une direction de référence aisément matérialisable et le principe consiste à estimer les mouvements du télescope par rapport à cette direction de référence.

Terme(s)-clé(s)
  • axe de rotation de référence

Espagnol

Conserver la fiche 4

Fiche 5 2001-08-13

Anglais

Subject field(s)
  • Applications of Electronics
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
CONT

During the first phase of rapid align, the liquid level signal controls the platform pitch erection. However... to avoid a large vertical error when the control of the platform pitch gimbal switches to the pitch pick-off in the second phase of rapid alignment, a phase reversal is required. The phase reversal is designed to keep all of the signal phasing correct while reversing the phase of the gyro pick-off signal. If the phase of the gyro pick-off were not reversed, the combined signals could null with a non-level gimbal and a non-vertical gyro spin axis. With the pick-off reversal, the same type of cancellation occurs but the gyro spin axis is vertical.

Terme(s)-clé(s)
  • gyroscope pick-off signal
  • gyro pick-off

Français

Domaine(s)
  • Applications de l'électronique
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Durant la première phase de l'alignement rapide, le signal du niveau à liquide commande l'érection en tangage de la plate-forme. Cependant, il est nécessaire d'inverser la phase afin d'éviter un signal important d'erreur de verticale lorsque la commande du cardan de tangage de la plate-forme est donnée au détecteur de tangage durant la deuxième phase de l'alignement rapide. Cette inversion de phase est conçue pour garder la mise en phase correcte du signal lorsque la phase du signal détecteur du gyroscope est renversée. Si la phase du signal détecteur du gyroscope n'était pas inversée, les signaux composés pourraient devenir nuls avec un cardan qui ne serait pas correctement en érection et un axe de rotation qui ne serait pas à la verticale. En effectuant l'inversion du signal détecteur, le même genre d'annulation se produit mais l'axe de rotation du gyroscope est à la verticale.

Espagnol

Conserver la fiche 5

Fiche 6 2001-08-13

Anglais

Subject field(s)
  • Flight Instruments and Equipment (Aeroindustry)
  • Aircraft Piloting and Navigation
  • Navigation Instruments
CONT

During the first phase of rapid align, the liquid level signal controls the platform pitch erection. However... to avoid a large vertical error when the control of the platform pitch gimbal switches to the pitch pick-off in the second phase of rapid alignment, a phase reversal is required. The phase reversal is designed to keep all of the signal phasing correct while reversing the phase of the gyro pick-off signal. If the phase of the gyro pick-off were not reversed, the combined signals could null with a non-level gimbal and a non-vertical gyro spin axis. With the pick-off reversal, the same type of cancellation occurs but the gyro spin axis is vertical.

Terme(s)-clé(s)
  • gyroscope pick-off reversal
  • gyro pick-off reversal

Français

Domaine(s)
  • Instruments et équipement de bord (Constructions aéronautiques)
  • Pilotage et navigation aérienne
  • Instruments de navigation
CONT

Durant le première phase de l'alignement rapide, le signal du niveau à liquide commande l'érection en tangage de la plate-forme. Cependant, il est nécessaire d'inverser la phase afin d'éviter un signal important d'erreur de verticale lorsque la commande du cardan de tangage de la plate-forme est donnée au détecteur de tangage durant la deuxième phase de l'alignement rapide. Cette inversion de phase est conçue pour garder la mise en phase correcte du signal lorsque la phase du signal détecteur du gyroscope est renversée. Si la phase du signal détecteur du gyroscope n'était pas inversée, les signaux composés pourraient devenir nuls avec un cardan qui ne serait pas correctement en érection et un axe de rotation qui ne serait pas à la verticale. En effectuant l'inversion du signal détecteur, le même genre d'annulation se produit mais l'axe de rotation du gyroscope est à la verticale.

Terme(s)-clé(s)
  • inversion du signal détecteur du gyroscope

Espagnol

Conserver la fiche 6

Fiche 7 2001-08-10

Anglais

Subject field(s)
  • Electromagnetism
  • Electric Rotary Machines - Types
  • Flight Instruments and Equipment (Aeroindustry)
CONT

Microsyn.... Pick-off function. The primary windings are excited by a 20V 3. 2 KHz signal. This signal produces an error signal in the secondary windings whenever the armature is not in a null position. Torquer function. A DC [direct current] signal is applied to the primary windings which produces a torque directly proportional to the AC [alternating current] current flow already present in the primary windings. The detection of torque is dependant on the polarity of the applied DC signal.

OBS

microsyn: An electromagnetic device often used as a pickoff in single-degree-of-freedom gyros and accelerometers. It has a stator, fastened to the sensor case, containing primary and secondary sets of windings, and a rotor, without windings, that is attached to the float.

Français

Domaine(s)
  • Électromagnétisme
  • Machines tournantes électriques - types
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Microsyn [...] Fonction de détection. Fonction de couple. Les bobines primaires sont excitées par un courant de 20 volts à 3.2 KHz et produisant un signal de sortie dans les bobines secondaires [...] à chaque fois que l'armature magnétique n'est pas au point zéro. Une erreur étant détectée, un courant continu alimentera les bobines primaires pour produire un couple dont l'amplitude sera directement proportionnelle au courant alternatif dans les bobines primaires. Le sens du couple dépend de la polarité du signal.

Espagnol

Conserver la fiche 7

Fiche 8 2001-08-10

Anglais

Subject field(s)
  • Applications of Electronics
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
CONT

Microsyn... Pick-off function. The primary windings are excited by a 20V 3. 2 KHz signal. This signal produces an error signal in the secondary windings whenever the armature is not in a null position.

OBS

microsyn: An electromagnetic device often used as a pickoff in single-degree-of-freedom gyros and accelerometers. It has a stator, fastened to the sensor case, containing primary and secondary sets of windings, and a rotor, without windings, that is attached to the float.

Français

Domaine(s)
  • Applications de l'électronique
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Microsyn [...] Fonction de détection. Les bobines primaires sont excitées par un courant de 20 volts à 3.2 KHz et produisant un signal de sortie dans les bobines secondaires [...] à chaque fois que l'armature magnétique n'est pas au point zéro.

Espagnol

Conserver la fiche 8

Fiche 9 1998-09-16

Anglais

Subject field(s)
  • Mechanical Transmission Systems
DEF

Change in null bias expressed as percent of rated signal. Null shift may occur with changes in supply pressure, temperature and other operating conditions.

Français

Domaine(s)
  • Transmissions mécaniques
DEF

Variation du décalage du zéro exprimé en pourcentage du signal nominal. La dérive du zéro peut être due à des variations de la pression d'entrée, de la température et à d'autres conditions d'utilisation.

Espagnol

Conserver la fiche 9

Fiche 10 1998-09-16

Anglais

Subject field(s)
  • Mechanical Transmission Systems
DEF

Input signal required to bring the valve to null, excluding the effects of valve hysteresis expressed as percent of rated signal.

Français

Domaine(s)
  • Transmissions mécaniques
DEF

Signal d'entrée nécessaire pour mettre au zéro en excluant les effets de l'hystérésis. On l'exprime en pourcentage du signal nominal.

Espagnol

Conserver la fiche 10

Fiche 11 1991-05-29

Anglais

Subject field(s)
  • Computer Graphics
DEF

A phenomenon whereby a new hologram diffracts energy out of the signal beam into the reference hologram, so obtaining a null signal after a timing period depending on a characteristic constant.

Français

Domaine(s)
  • Infographie

Espagnol

Conserver la fiche 11

Fiche 12 1987-09-22

Anglais

Subject field(s)
  • Air Transport

Français

Domaine(s)
  • Transport aérien

Espagnol

Conserver la fiche 12

Fiche 13 1980-08-12

Anglais

Subject field(s)
  • Electrical Measurements
OBS

Two signal nulls (180 degrees apart) are indicated by a reduction in audio level and a dip of the tuning meter needle.

Français

Domaine(s)
  • Mesures électriques
OBS

Principe [du VDF à oscilloscope]: réception sur aérien tournant à vitesse uniforme: le signal reçu (porteuse pure) se trouve alors modulé (modulation à double bandes latérales sans porteuse) et présente un nul deux fois par tour du diagramme; (...)

Espagnol

Conserver la fiche 13

Fiche 14 1976-06-19

Anglais

Subject field(s)
  • Flight Instruments and Equipment (Aeroindustry)

Français

Domaine(s)
  • Instruments et équipement de bord (Constructions aéronautiques)

Espagnol

Conserver la fiche 14

Fiche 15 1976-06-19

Anglais

Subject field(s)
  • Air Transport

Français

Domaine(s)
  • Transport aérien
OBS

radio-navigation

Espagnol

Conserver la fiche 15

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :