TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

PARAMETER IDENTIFICATION [5 fiches]

Fiche 1 2015-12-01

Anglais

Subject field(s)
  • IT Security
  • Banking
DEF

An optional security feature in the form of an algorithm code and a verification value.

OBS

personal identification number control parameters; PINPARM: term, abbreviation and definition standardized by the International Organization for Standardization (ISO) in 1993.

Terme(s)-clé(s)
  • personal identification number control parameter

Français

Domaine(s)
  • Sécurité des TI
  • Banque
DEF

Dispositif de sécurité facultatif sous la forme d'un code algorithmique et d'une valeur de vérification.

OBS

paramètres de contrôle du numéro d'identification personnel; PINPARM : terme, abréviation et définition normalisés par l'Organisation internationale de normalisation (ISO) en 1993.

Terme(s)-clé(s)
  • paramètre de contrôle du numéro d'identification personnel

Espagnol

Conserver la fiche 1

Fiche 2 2007-01-31

Anglais

Subject field(s)
  • Remote Sensing
DEF

[A signature that] draws the scattering coefficient as a function of any assumed transmit and receive antenna polarization, allowing the measurement of the variation of the scattering coefficient with polarization.

CONT

Radar polarimetry allows the identification/interpretation of scattering mechanisms in natural media by employing differences in the polarisation signature for purposes of classification and parameter estimation.

OBS

polarisation signature: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

Français

Domaine(s)
  • Télédétection
DEF

[Signature qui] décrit le coefficient de rétrodiffusion en fonction des paramètres de polarisation pour n'importe quelle configuration d'antenne, [ce qui] permet d'évaluer le taux de variation de la rétrodiffusion relativement à la polarisation.

OBS

La polarimétrie radar permet l'identification et l'interprétation des mécanismes de diffusion de milieux naturels grâce aux différences entre les signatures de polarisation et ce, à des fins de classification et d'estimation de paramètres.

OBS

signature de polarisation : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

Espagnol

Campo(s) temático(s)
  • Teledetección
Conserver la fiche 2

Fiche 3 2003-06-13

Anglais

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Mineralogy
CONT

X-ray powder diffraction is used in the identification of crystalline phases in unknown samples, finding the lattice parameter and other lattice related information, quantitative determination of phases in multiphase samples, finding the orientation in single crystals, and stereographic projections. The samples must be crystalline solids such as metals, ceramics, rocks etc. These samples are usually about 1 mg in size. If the sample fits in the sample holder then there is no preparation necessary otherwise the sample may have to be crushed in order to fit. The sample takes less than one hour to be analyzed for qualitative analysis in major phases and up to 16 hours for trace phases. The quantitative analysis can take several minutes to several hours after set up. There are several detectors used in XRPD varying from films to cameras to diffractometers.

CONT

Powder X-Ray Diffraction. Powders of crystalline materials diffract X-Rays. A beam of X-rays passing through a sample of randomly-oriented micro-crystals produces a pattern of rings on a distant screen. Powder X-Ray diffraction provides less information than single-crystal diffraction, however, it is much simpler and faster. Powder X-Ray diffraction is useful for confirming the identity of a solid material and determining crystallinity and phase purity. Modern powder X-Ray diffractometers consist of an X-Ray source, a movable sample platform, an X-Ray detector, and associated computer-controlled electronics. The sample is either packed into a shallow cup-shaped holder or deposited as a slurry onto a quartz substrate, and the sample holder spins slowly during the experiment to reduce sample heating. The X-Ray source is usually the same as used in single-crystal diffractometers, Mo or Cu. The X-Ray beam is fixed and the sample platform rotates with respect to the beam by an angle theta. The detector rotates at twice the rate of the sample and is at an angle of 2 theta with respect to the incoming X-Ray beam.

CONT

Fine particles such as clays must be separated from larger particles and measured separately if they are to be detected properly. To reduce errors associated with preferred orientation of minerals, samples are most commonly ground to a powder before analysis, a technique known as powder X-ray diffraction.

CONT

X-ray powder diffraction (XRD) is a direct method for qualitative and quantitative characterization of fine-grained materials such as clinker and cement, and may also be used for analysis of raw materials. Each phase produces a unique diffraction pattern independent of others, with the intensity of each pattern proportional to that phases concentration in a mixture.

Terme(s)-clé(s)
  • x-rays powder diffraction
  • x rays powder diffraction
  • x ray powder diffraction
  • powder x-rays diffraction
  • powder x rays diffraction
  • powder x ray diffraction

Français

Domaine(s)
  • Physique radiologique et applications
  • Minéralogie
CONT

Diffraction de rayons sur poudres : analyse quantitative de composés modèles du ciment anhydre. [...] Ce stage sera consacré à la caractérisation par diffraction des rayons X de mélanges d'alites de synthèse M1 et M3. La méthode expérimentale utilisée sera la diffraction des rayons X sur poudres jointe aux autres méthodes de laboratoire associées.

CONT

À l'aide de la diffraction de rayons X de poudres, différentes formes polymorphiques peuvent être détectées pour des molécules à activité pharmacologique.

Terme(s)-clé(s)
  • diffraction de rayons-X sur poudres

Espagnol

Conserver la fiche 3

Fiche 4 2001-03-16

Anglais

Subject field(s)
  • Information Theory
DEF

Recursive parameter estimation techniques based on the use of an adjustable predictor and a parameter adaptation algorithm that processes sequentially the input-output data as they are available.

Terme(s)-clé(s)
  • online parameter identification

Français

Domaine(s)
  • Théorie de l'information
CONT

L'identification en ligne des paramètres de la machine en se basant sur la connaissance des grandeurs mesurables pour assurer la robustesse.

Espagnol

Conserver la fiche 4

Fiche 5 1988-06-02

Anglais

Subject field(s)
  • Metallurgy - General
  • Mining Operations
OBS

Subject-test CANMET-METALLURGY

Français

Domaine(s)
  • Métallurgie générale
  • Exploitation minière

Espagnol

Conserver la fiche 5

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :