TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

PLASMA DETECTOR [10 fiches]

Fiche 1 2011-07-12

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A detector that responds to changes in either the dielectric constant of a radio-frequency plasma or the potential difference between capacitor plates arising from variations in the composition of the carrier gas as solutes are eluted from the gas chromatography [GC] column.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 1

Fiche 2 2004-10-22

Anglais

Subject field(s)
  • Scientific Instruments
  • Research Experiments in Space
CONT

The Bragg Crystal Spectrometer(BCS) is designed to study plasma heating and dynamics during the impulsive phase of solar flares. It consists of two bent crystal spectrometers, BCS-A and BCS-B, that observe the H-like line complex of Fe XXVI, and He-like complexes of Fe XXV, Ca XIX and S XV. Each spectrometer consists of a double detector placed behind a pair of germanium crystals that diffract the incoming X-rays into the detectors. The two structures are mounted at the front of the Yohkoh spacecraft, on either side of the central panel, with a thermal filter mounted in front of each spectrometer. The crystal dispersion axes are oriented north-south.

Français

Domaine(s)
  • Instruments scientifiques
  • Travaux de recherche dans l'espace
CONT

Un spectromètre à cristal de Bragg conique focalise un spectre X sur la cathode de la caméra à balayage de fente.

Espagnol

Conserver la fiche 2

Fiche 3 2004-10-15

Anglais

Subject field(s)
  • Space Physics
DEF

A device for measuring the electrostatic and electromagnetic components of local plasma waves in three dimensions.

Terme(s)-clé(s)
  • plasma wave detector

Français

Domaine(s)
  • Physique spatiale
CONT

SAKIGAKE: Lancée le 8 janvier 1985, cette sonde japonaise emportait un magnétomètre, un détecteur d'ondes de plasma et un analyseur d'ions. Elle a traversé, en mars 1986, la queue de plasma de la comète, en passant à quelques 7 millions de kilomètres de son noyau.

Espagnol

Conserver la fiche 3

Fiche 4 2004-03-18

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Separation of spectral and non-spectral interferences by on-line high performance ion chromatography inductively coupled plasma sector field mass spectrometry (HPIC-ICP-SFMS) for accurate determination of234U,235U,238U and232Th in industrial ores.

CONT

Determination of trace elements in human milk by inductively coupled plasma sector field mass spectrometry (ICP-SFMS).

CONT

Indiana University Laboratory for Spectrochemistry. Plasma Source Mass Spectrometry. "Single-Crystal Scintillator-Based Array Detector for Sector-Field Mass Spectrometry, "[by] David A. Solyom. Beginning with the use of photographic plates in the first quarter of this century, array detectors have had a long history of usage in mass-spectrometric analysis. Array detectors are position-sensitive devices capable of independently measuring ion signals that are incident at different locations on the detector's face. Currently popular among the different types of array detectors available for mass spectrometry are microchannel-plate(s)(MCP) coupled with a phosphor.... The electrons emitted from the rear of the MCP strike the phosphor being held in close proximity(1mm) to the MCP. The phosphor screen is sensitive to the incident electrons and will emit photons in response. The number of emitted photons is proportional to the number of incident electrons and the location on the phosphor from which the photons are emitted coincides with the location of the incident electrons. The photons from the phosphor can then be converted into a proportional electronic signal by an imaging device such as a CCD or CID detector array.

Français

Domaine(s)
  • Chimie analytique
CONT

spectrométrie de masse à secteurs à plasma induit (ICP-SFMS).

OBS

Il existe plusieurs traductions du terme «inductively coupled plasma (ICP)» : le plus proche de la description de la technique est «plasma induit par un courant de haute fréquence», le plus simple est «torche à plasma»; pour décrire un «sector field mass spectrometer» nous parlons de «spectromètre de masse à secteur magnétique» ou, plus brièvement, de «spectromètre de masse magnétique». L'équivalent français de ICP-SFMS serait donc «torche à plasma couplée à un spectromètre de masse magnétique» (version courte) ou «plasma induit par un courant de haute fréquence associé à un spectromètre de masse à secteur magnétique» (version longue). [Source : Guy Bouchoux, Secrétaire, Société française de spectrométrie de masse, École Polytechnique, DCMR, Palaiseau (France)]

Espagnol

Conserver la fiche 4

Fiche 5 2003-11-25

Anglais

Subject field(s)
  • Space Physics
  • Scientific Research Equipment
DEF

A device for measuring the density, composition, temperature, velocity and three-dimensional distribution of plasmas that exist in interplanetary, regions and within planetary magnetospheres.

Français

Domaine(s)
  • Physique spatiale
  • Matériel et équipement (Recherche scientifique)

Espagnol

Conserver la fiche 5

Fiche 6 2003-06-17

Anglais

Subject field(s)
  • Orbital Stations
CONT

The Environmental Monitoring Package (EMP) measures a number of contamination environment parameters (radiation, plasma, mass deposition of contaminants) external to the Station as a service to the attached payloads community, which requires characterisation of operational conditions.

CONT

[The] Environment Monitoring Package [includes a] contamination sensor, [a] plasma detector, [a] radiation monitor [and a] high resolution camera).

OBS

environmental monitoring package; EMP: term and abbreviation officially approved by the International Space Station official approval Group (ISSOAG).

Français

Domaine(s)
  • Stations orbitales
OBS

instrumentation de surveillance environnementale; EMP : terme et abréviation uniformisés par le Groupe de travail de la terminologie de la Station spatiale internationale (GTTSSI).

Espagnol

Conserver la fiche 6

Fiche 7 2002-06-17

Anglais

Subject field(s)
  • Space Centres
CONT

The European Technology Exposure Facility(EuTEF) is a programmable, multifunctional, fully automated system. The modular architecture provides uniform interfaces for instruments-up to seven instrument modules can be accommodated and operated simultaneously. Five instruments are under development :-TRIBOLAB, a tribology testbed developed by INTA(E) ;-PLEGPAY, a plasma electron gun payload developed by LABEN(I) ;-MEDET, the Material Exposure and Degradation Experiment on TEF, developed by CNES/ESA/ONERA/University of Southampton;-DEBIE-2, a space debris detector developed by ESA(the first is flying on the Proba satellite) ;-FIPEX, the Flux Probe Experiment developed by the University of Stuttgart(D).

OBS

Columbus precursor flights.

Français

Domaine(s)
  • Centres spatiaux

Espagnol

Conserver la fiche 7

Fiche 8 2001-11-27

Anglais

Subject field(s)
  • Printed Circuits and Microelectronics
  • Industrial Techniques and Processes
CONT

The lack of margins in selectivity and the sensitivity of etching rates to other variables such as loading (i.e., the total area to be etched) in plasma etching have made it necessary to develop a positive means of determining the moment etching should stop, rather than relying of fixed times. Most end-point detectors developed to date are based on gas analysis of one sort or another. They determine the instant that either the material being etched has largely disappeared or the material beneath that layer is being attacked. Detecting spectral lines in the plasma related to a particular reaction product is the simplest way, but it cannot be employed in all cases.

Français

Domaine(s)
  • Circuits imprimés et micro-électronique
  • Techniques industrielles

Espagnol

Conserver la fiche 8

Fiche 9 2001-04-01

Anglais

Subject field(s)
  • Space Exploration Equipment and Tools
CONT

Positively or negatively charged ions entering the sensor are first detected by the charge that they induce when they fly through the entrance grid. This charge signal will only be evaluated if the ion subsequently impacts the impact plasma detector. Dust particles(charged or uncharged) are detected by the plasma produced during the impact on the gold target of the sensor.

Français

Domaine(s)
  • Équipement et outillage d'exploration spatiale

Espagnol

Conserver la fiche 9

Fiche 10 1999-09-07

Anglais

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
CONT

The microwave plasma detector uses a microwave plasma to excite compounds and/or their microwave-produced fragments. Photometric measurement of the emitted radiation completes the detection system.

OBS

Free electrons thus produced cause the solute molecules to fragment into free atoms and diatomic molecules which give rise to spectra. The technique is limited but is suitable for the selective study of compounds containing halogens, phosphorus and sulphur atoms.

Français

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
CONT

Détecteurs sélectifs. [...] Nous citerons encore les détecteurs électrochimiques permettant d'obtenir des réponses sélectives pour les composés azotés, chlorés ou soufrés, et d'autres, tels que le détecteur à ionisation d'argon ou d'hélium, détectant des traces de gaz permanents, de même que le détecteur à ionisation par haute fréquence. Pour les atomes métalliques, on pourra utiliser le détecteur à plasma excité par micro-ondes.

Terme(s)-clé(s)
  • détecteur à plasma excité par microonde

Espagnol

Conserver la fiche 10

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :