TERMIUM Plus®

Par le Bureau de la traduction

Dans les médias sociaux

Consultez la banque de données terminologiques du gouvernement du Canada.

TURN-ON TIME [3 fiches]

Fiche 1 - données d’organisme externe 2002-02-27

Anglais

Subject field(s)
  • Electrical Engineering
  • Explosives and Pyrotechnical Materials (Industries)
  • Compartment - Canadian Nuclear Safety Commission
CONT

Electronic components for firing sets (switching devices and pulse discharge capacitors): (a) switching devices: (1) cold-cathode tubes ... (2) triggered spark-gaps ... and (3) modules or assemblies with a fast switching function having all of the following characteristics: (i) anode peak voltage rating greater than 2 000 V; (ii) anode peak current rating of 500 A or more; and (iii) turn-on time of 1 s or less ...

OBS

Regulation cited: Nuclear Non-Proliferation Import and Export Control Regulations.

Français

Domaine(s)
  • Électrotechnique
  • Explosifs et artifices (Industries)
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Composants électroniques pour les appareils de mise à feu (dispositifs de commutation et condensateurs à décharge d'impulsions) : a) dispositifs de commutation : (1) tubes à cathode froide [...] (2) éclateurs à étincelle [...] (3) modules ou assemblages à commutation rapide possédant toutes les caractéristiques suivantes : (i) tension anodique nominale de pointe supérieure à 2 000 V; (ii) courant de plaque nominal de pointe égal ou supérieur à 500 A; (iii) temps de commutation égal ou inférieur à 1 s [...]

OBS

Règlement cité : Règlement sur le contrôle de l'importation et de l'exportation aux fins de la non-prolifération nucléaire.

Espagnol

Conserver la fiche 1

Fiche 2 2001-08-21

Anglais

Subject field(s)
  • Electrical Power Supply
DEF

The time from the initial application of power until a sensor produces a specified useful output, though not necessarily at the accuracy of full specification performance.

CONT

External Remote Control: Inputs per channel with common ground. Connection of ground to a remote input switches the amplifier input from the line source to the mic source. The mic turn-on time is immediate with 1.5 second line level turn-on time after manual gating.

CONT

Advanced dynamic detectors ... Specifications ... Electrical ... Turn-on time: typ. 60s from power-on.

Français

Domaine(s)
  • Alimentation (Distribution électrique)
DEF

Après sa mise sous tension, temps nécessaire à un appareil électrique pour en arriver à un rendement minimal.

Espagnol

Conserver la fiche 2

Fiche 3 2001-02-02

Anglais

Subject field(s)
  • Printed Circuits and Microelectronics
  • Electronic Circuits Technology
DEF

The time required for an output to turn on (sink current, to ground output, to go to 0 volt). It is the propagation time of an appropriate input signal to cause the output to go to 0 volt.

Français

Domaine(s)
  • Circuits imprimés et micro-électronique
  • Technologie des circuits électroniques

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :