Fiche 1 2015-03-02

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
OBS

[unit heaters are] self-contained, automatically controlled, chimney- or vent-connected air heating appliances having an integral means for circulation of air. [They are] of the floor mounted or suspended type.

OBS

When suspended heaters are used with free delivery, higher entering-air temperatures must be used over and above the room temperature at breathing level.

OBS

This term occurs under "unit heaters" in the index, which is unpaginated.

Terme(s)-clé(s)
  • ceiling unit heater
  • ceiling-mounted unit heater

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Les différents types d'aérothermes existants permettent une adaptation aisée aux besoins; ils se divisent en appareils muraux et en appareils suspendus dits "plafonniers" (...). Parmi les progrès réalisés ces dernières années dans ce domaine, on relèvera par exemple l'apparition d'aérothermes suspendus à tête de diffusion tournante (...)

Terme(s)-clé(s)
  • aérotherme plafonnier
  • plafonnier

Espagnol

Conserver la fiche 1

Fiche 2 2011-09-23

Anglais

Subject field(s)
  • Scientific Research Equipment
  • Equipment (Chemistry)
  • Petrochemistry
OBS

Term(s) taken from a Canadian laboratory-equipment company's catalogue.

Français

Domaine(s)
  • Matériel et équipement (Recherche scientifique)
  • Équipement (Chimie)
  • Chimie du pétrole
OBS

Terme(s) tiré(s) du catalogue d'une compagnie canadienne d'équipement de laboratoire.

Espagnol

Conserver la fiche 2

Fiche 3 2011-08-23

Anglais

Subject field(s)
  • Scientific Research Equipment
  • Equipment (Chemistry)
  • Petrochemistry
OBS

Term(s) taken from a Canadian laboratory-equipment company's catalogue.

Français

Domaine(s)
  • Matériel et équipement (Recherche scientifique)
  • Équipement (Chimie)
  • Chimie du pétrole
OBS

Terme(s) tiré(s) du catalogue d'une compagnie canadienne d'équipement de laboratoire.

Espagnol

Conserver la fiche 3

Fiche 4 2010-02-08

Anglais

Subject field(s)
  • Heating
CONT

Heavy-duty floor-mounted unit heaters are available: without connected ductwork but with high velocity nozzles and for application with ductwork.

Français

Domaine(s)
  • Chauffage
CONT

Aérothermes sur pieds. Surtout utilisés aux USA et en Angleterre, la batterie de chauffage se trouve en partie basse de la carrosserie, la partie supérieure contenant, montés sur le même arbre, un, deux ou plusieurs ventilateurs à doubles ouïes avec leurs manches de soufflage. Bien que prévus pour être posés sur le sol, on peut aussi les fixer au mur ou au plafond.

Espagnol

Conserver la fiche 4

Fiche 5 2008-05-13

Anglais

Subject field(s)
  • Aircraft Systems
DEF

A unit used to raise the temperature of a fluid.

CONT

[Includes] cabin supercharger, equipment cooling, heater, heater fuel system, expansion turbine, valves, scoops, ducts, etc.

Français

Domaine(s)
  • Circuits des aéronefs
DEF

Appareil dans lequel on élève la température d'un corps, généralement un fluide.

CONT

[Comprend] le compresseur de cabine, les dispositifs de refroidissement des équipements, le réchauffeur, le circuit carburant du réchauffeur, la turbine de détente, les vannes, manches à air, canalisations, etc.

Espagnol

Conserver la fiche 5

Fiche 6 2007-07-23

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

A self-contained heating appliance, which may or may not include an integral fan for circulating air, which may be of the floor-mounted or suspended type, intended for the heating of the space in which it is installed.

CONT

... unit heaters in present use can usually be classified according to one or more methods: 1. By Heating Medium ... a) steam, b) hot water, c) gas indirect-fired, d) oil indirect-fired, e) electric. 2. By Type of Fan ... a) propeller, b) centrifugal, and c) remote air mover ... 3. By Arrangement of Elements ... a) the draw-through type, in which the fan draws air through and b) the blow-through type, in which the fan blows air through the heating element. Indirect-fired unit heaters are always of the blow-through type.

CONT

A unit heater [means] a forced convection heating device of two types: 1) an assembly of encased heating surface with fan and motor (or turbine) and for connection to a source of steam or hot water; 2) an assembly of the above plus a fuel burner so that the device is for connection to a source of oil or gas (or supplied with coal) and not to steam or water lines.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
DEF

Appareil autonome de chauffage comprenant un ventilateur et un élément chauffant, pulsant directement l'air chaud dans le local à chauffer.

CONT

L'aérotherme peut être à chauffage direct, avec le mazout ou le gaz comme source de chaleur, ou à chauffage indirect; il comporte alors un corps de chauffe en tube de cuivre ou en tube d'acier avec ailettes. Les aérothermes comprennent un groupe moto-ventilateur qui peut être hélicoïde [...] ou centrifuge [...] L'aérotherme comporte de plus une carcasse sur laquelle sont branchées une ou plusieurs bouches de chauffage. À sa partie basse est prévue la reprise d'air. Très souvent, une autre tubulure est prévue pour l'alimentation en air neuf [...] Ces appareils, prévus pour le chauffage des grandes surfaces [ateliers, entrepôts], peuvent être suspendus, muraux ou sur socles.

Espagnol

Campo(s) temático(s)
  • Hornos y calderas (Calefacción)
DEF

Aparato de calefacción consistente en una fuente de calor y un ventilador que inyecta directamente el aire caliente en el local que se ha de caldear.

Conserver la fiche 6

Fiche 7 2007-01-17

Anglais

Subject field(s)
  • Drying Techniques (Farming)
  • Heating

Français

Domaine(s)
  • Dessiccation (Techniques agricoles)
  • Chauffage
DEF

Appareil alimentant le séchoir en air chaud. Il comporte généralement un brûleur, une chambre de combustion, éventuellement un échangeur, un ventilateur et un système de sécurité et de régulation.

Espagnol

Campo(s) temático(s)
  • Desecación (Técnicas agrícolas)
  • Calefacción
Conserver la fiche 7

Fiche 8 - données d’organisme externe 2006-03-24

Anglais

Subject field(s)
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission

Français

Domaine(s)
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire

Espagnol

Conserver la fiche 8

Fiche 9 1996-07-26

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Electric unit heaters are used where low cost electric power is available, or for isolated locations, intermittent use, supplementary heating, or temporary service. Typical applications are ticket booths, watchmen's offices, factory offices, locker rooms, and other types of isolated rooms scattered over large areas. Electric units are particularly useful in isolated and untended pumping stations or pits, where they may be thermostatically controlled to prevent freezing temperatures.

OBS

The term unit heater denotes an assembly of elements, the principal function of which is to heat a space. The essential elements are a fan and motor, a heating element, and an enclosure. Filters, dampers, directional outlets, duct collars, combustion chambers, and flues may also be included. The various types of unit heaters in present use can usually be classified according to one or more methods. 1. By Heating Medium. Under this classification five heating media can be considered: a) steam, b) hot water, c) gas indirect-fired, d) oil indirect-fired, e) electric.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Il existe des aérothermes qui ne sont pas alimentés par un fluide chauffant, mais dans lesquels la chaleur est produite directement. Ce sont d'une part les aérothermes électriques, dont la batterie chauffante est constituée par des résistances chauffantes (fils au nickel-chrome, par exemple) qui, portées au rouge, atteignent une température de 300°C. D'autre part les aérothermes à feu direct [...]

Espagnol

Conserver la fiche 9

Fiche 10 1991-01-30

Anglais

Subject field(s)
  • Heating
CONT

Revolving and Fixed Discharge Unit Heaters. .5 (Revolving) (Fixed) discharge: mounted on a sheet steel air chamber suspended from heater casing on a prelubricated sealed ball bearings.

Français

Domaine(s)
  • Chauffage
CONT

Aérothermes à bouche de soufflage (tournante) (fixe). .5 L'appareil doit comporter ( ) bouche(s) de soufflage (tournante(s] (fixe(s] montée(s) sur un caisson d'air en tôle d'acier suspendu à l'habillage enfermant le serpentin par l'intermédiaire d'un roulement à bille central prélubrifié et scellé.

Espagnol

Conserver la fiche 10

Fiche 11 1991-01-30

Anglais

Subject field(s)
  • Heating
CONT

Revolving and Fixed Discharge Unit Heaters. .5 (Revolving) (Fixed) discharge: mounted on a sheet steel air chamber suspended from heater casing on a prelubricated sealed ball bearings.

Français

Domaine(s)
  • Chauffage
CONT

Aérotherme à bouche de soufflage (tournante) (fixe). .5 L'appareil doit comporter ( ) bouche(s) de soufflage (tournante(s] (fixe(s] montée(s) sur un caisson d'air en tôle d'acier suspendu à l'habillage enfermant le serpentin par l'intermédiaire d'un roulement à bille central prélubrifié et scellé.

Espagnol

Conserver la fiche 11

Fiche 12 1991-01-30

Anglais

Subject field(s)
  • Heating
CONT

Vents: on liquid type unit heaters, install standard air vent with cock.

Français

Domaine(s)
  • Chauffage
CONT

Purgeurs: munir les aérothermes du type à fluide caloporteur liquide de purgeurs d'air standard avec robinet.

OBS

Fluide caloporteur: qui évacue la chaleur d'une machine thermique.

Espagnol

Conserver la fiche 12

Fiche 13 1990-01-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Horizontal gas-fired furnace ... does not come equipped with its own blower.... Duct furnaces are normally certified for operation either upstream or downstream of an air conditioner cooling coil. A combination blower and duct furnace is also available, but it is called a blower unit heater. Duct furnaces and blower unit heaters are available in natural gas, LP, oil, and electric models.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Les appareils à émission individuelle (poêles à accumulation ou appareil à chauffage direct tels que panneaux radiants lumineux ou obscurs, aérothermes soufflants).

Espagnol

Conserver la fiche 13

Fiche 14 1990-01-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Cabinet unit heaters are used for applications in which a more attractive appearance is desired. They are suitable for free delivery or low static pressure duct applications, they may be equipped with filters, and they can be arranged to discharge either horizontally or vertically up or down.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

Certains aérothermes ont une présentation très soignée. L'enveloppe quelque fois est en matière plastique.

Espagnol

Conserver la fiche 14

Fiche 15 1990-01-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

For area heating, horizontal-blow unit heaters in exterior zones should be located so as to blow either along the exposure or toward it at a slight angle. Where possible, multiple units should be arranged so that the discharge airstreams support each other and create a general circulatory motion in the space ... Horizontal unit heaters should have discharge outlets located well above head level, and both horizontal and vertical units should be so applied that the heated airstream will be delivered to the occupied zone at temperatures and velocities which are not objectionable. where possible, units should be located so that the discharge air flow is into open spaces, such as aisles, and not directly on the occupants.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Actuellement on fabrique surtout des aérothermes à soufflage horizontal; l'axe du jet d'air est situé à 3 ou 4 m de hauteur et sa portée peut atteindre 60 m avec des vitesses de soufflage de l'ordre de 15 m/s. L'utilisation des aérothermes avec de telles portées du jet d'air nécessite que ce jet ne rencontre aucun obstacle sur lequel il soit susceptible de se réfléchir, ce qui implique des locaux bien dégagés et hauts de plafond. Moyennant cette condition, on peut obtenir un chauffage régulier d'un local au moyen d'aérothermes en très petit nombre : les aérothermes à soufflage horizontal peuvent très bien avoir des puissances de plusieurs centaines de milliers de kilocalories. C'est un mode de chauffage convenant bien à des ateliers, garages, halls industriels suffisamment dégagés.

Espagnol

Conserver la fiche 15

Fiche 16 1990-01-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Les aérothermes verticaux : la batterie est horizontale et l'axe du ventilateur vertical. En général, l'air est soufflé vers le bas pour éviter les courants d'air. Un cône de diffusion répartit l'air.

Espagnol

Conserver la fiche 16

Fiche 17 1990-01-30

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

The various types of unit heaters in present use can usually be classified according to one or more methods. 1. By Heating Medium ... 2. By Type of Fan. Under this classification three types of fans can be considered: a) propeller, b) centrifugal, and c) remote air mover. Propeller fan units may be of the horizontal-blow or down-blow type. Centrifugal fan units may be of the smaller cabinet type or larger industrial type. Units with remote air movers are known as duct unit heaters. 3. By Arrangement of Elements.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

L'aérotherme comporte une batterie et un ventilateur hélicoïde et des volets réglables qui dirigent l'air vers l'endroit désiré.

OBS

Les aérothermes comprennent un groupe moto-ventilateur qui peut être hélicoïde, pour les gros débits et les faibles vitesses, ou centrifuge, pour les vitesses élevées.

Espagnol

Conserver la fiche 17

Fiche 18 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
OBS

Propeller fan units are generally used in free-delivery applications.... Down-blow units are employed in high-ceiling spaces and where floor and wall space limitations dictate an out-of-the-way location for the heating equipment. Down-blow units may be supplied with an adjustable diffuser to vary the air discharge pattern from a high velocity vertical jet (to achieve the maximum distance of downward throw) to a horizontal discharge of lower velocity (to prevent excessive air motion in the zone of occupancy). Revolving diffusers are also available.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

Il existe trois principaux types d'appareils, suivant la direction vers laquelle est dirigé le flux d'air chaud : l'air chaud est soufflé vers le bas; (...) l'air chaud est soufflé horizontalement par le haut; (...) l'air chaud est soufflé obliquement vers le bas sous un angle variable suivant l'inclinaison des volets (...)

Espagnol

Conserver la fiche 18

Fiche 19 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

Unit heater supported from or recessed in the wall of the room or space to be heated.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

les aérothermes muraux (...) sont fixés au mur ou à la charpente. La batterie est verticale et l'axe du ventilateur horizontal. L'air est soufflé vers le bas presque horizontalement pour augmenter la portée et pour ne pas gêner les occupants.

OBS

Ces appareils [aérothermes] prévus pour le chauffage des grandes surfaces, peuvent être suspendus, muraux ou sur socles. Les modèles muraux sont réservés, de préférence, aux locaux de faible hauteur (inférieure à 4 m).

Espagnol

Conserver la fiche 19

Fiche 20 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Steam or hot water unit heaters are relatively inexpensive but require a boiler and piping system ... steam or hot water heating is most frequently used in new installations involving a relatively large number of units and in existing systems which have sufficient capacity to handle the additional load.

OBS

The term unit heater denotes an assembly of elements, the principal function of which is to heat a space. The essential elements are a fan and motor, a heating element, and an enclosure. Filters, dampers, directional outlets, duct collars, combustion chambers, and flues may also be included.... The various types of unit heaters in present use can usually be classified according to one or more methods. 1. By Heating Medium. Under this classification five heating media can be considered: a) steam, b) hot water, c) gas indirect-fired, d) oil indirect-fired, e) electric.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

Ces appareils [aérothermes] possèdent une surface de chauffe constituée par une batterie de tuyaux à ailettes en acier, en cuivre ou en aluminium. Cette batterie est alimentée par une installation de chauffage central à eau chaude ou à vapeur dans les mêmes conditions que les corps de chauffe ordinaires.

OBS

Le chauffage par aérothermes n'est pas à proprement parler un chauffage à air chaud. La chaleur est distribuée jusqu'aux locaux à chauffer par un fluide chauffant quelconque : eau chaude, eau surchauffée, vapeur haute ou basse pression et l'aérotherme joue le rôle d'un échangeur où le fluide chauffant cède de la chaleur à l'air par convection forcée.

Espagnol

Conserver la fiche 20

Fiche 21 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

The various types of unit heaters in present use can usually be classified according to one or more methods. 1. By Heating Medium ... 2. By Type of Fan. Under this classification three types of fans can be considered: a)propeller, b) centrifugal, and c) remote air mover. Propeller fan units may be of the horizontal-blow or down-blow type. Centrifugal fan units may be of the smaller cabinet type or larger industrial type. Units with remote air movers are known as duct unit heaters. 3. By Arrangement of Elements.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

Les aérothermes comprennent un groupe moto-ventilateur qui peut être hélicoïde, pour les gros débits et les faibles vitesses, ou centrifuge, pour les vitesses élevées.

Espagnol

Conserver la fiche 21

Fiche 22 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Steam and hot water unit heaters are relatively inexpensive but require a boiler and piping system.... steam or hot water heating is most frequently used in new installation involving a relatively large number of units and in existing systems which have sufficient capacity to handle the additional load.

OBS

The term unit heater denotes an assembly of elements, the principal function of which is to heat a space. The essential elements are a fan and motor, a heating element, and an enclosure. Filters, dampers, directional outlets, duct collars, combustion chambers, and flues may also be included. The various types of unit heaters in present use can usually be classified according to one or more methods. 1. By Heating Medium. Under this classification five heating media can be considered: a) steam, b) hot water, c) gas indirect-fired, d) oil indirect-fired, e) electric.

OBS

These [unfired unit] heaters include those devices that use steam or hot water as the heating medium, delivered to the device by pipe.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
OBS

Ces appareils [aérothermes] possèdent une surface de chauffe constituée par une batterie de tuyaux à ailettes en acier, en cuivre ou en aluminium. Cette batterie est alimentée par une installation de chauffage central à eau chaude ou à vapeur dans les mêmes conditions que les corps de chauffe ordinaires.

OBS

Le chauffage par aérothermes n'est pas à proprement parler un chauffage à air chaud. La chaleur est distribuée jusqu'aux locaux à chauffer par un fluide chauffant quelconque : eau chaude, eau surchauffée, vapeur haute ou basse pression et l'aérotherme joue le rôle d'un échangeur où le fluide chauffant cède de la chaleur à l'air par convection forcée.

Espagnol

Conserver la fiche 22

Fiche 23 1986-11-20

Anglais

Subject field(s)
  • Heating

Français

Domaine(s)
  • Chauffage

Espagnol

Conserver la fiche 23

Fiche 24 1986-11-20

Anglais

Subject field(s)
  • Heating

Français

Domaine(s)
  • Chauffage

Espagnol

Conserver la fiche 24

Fiche 25 1986-11-20

Anglais

Subject field(s)
  • Electric Heating

Français

Domaine(s)
  • Chauffage électrique

Espagnol

Conserver la fiche 25

Fiche 26 1986-11-20

Anglais

Subject field(s)
  • Electric Heating

Français

Domaine(s)
  • Chauffage électrique

Espagnol

Conserver la fiche 26

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :