CAVITE RESONNANTE OPTIQUE [9 fiches]

Fiche 1 2010-06-14

Anglais

Subject field(s)
  • Optics
  • Lasers and Masers
  • Navigation Instruments
  • Measuring Instruments (Engineering)
DEF

A gyro in which two laser beams travel in opposite directions over a ring-shaped path formed by three or more mirrors ...

OBS

Rotation [in this device] is thus measured without the use of a spinning mass.

OBS

The laser gyro is not technically a gyro since it has no rotating mass; however, it functions as a rate-integrating gyro.

OBS

A laser gyro has several advantages over a mechanical gyro system. The overall unit can be made smaller, lighter, and more sensitive. Also, because it has no moving parts it is less likely to break down and so is more reliable.

Français

Domaine(s)
  • Optique
  • Masers et lasers
  • Instruments de navigation
  • Instruments de mesure (Ingénierie)
DEF

Gyroscope sans pièces mécaniques, qui fait appel aux propriétés de l’optique cohérente.

CONT

Le gyrolaser est constitué par un oscillateur optique (laser) émettant deux ondes progressives parcourant en sens inverse un chemin optique de forme en plan triangulaire, dont les sommets sont constitués par des miroirs. Lorsque l’ensemble tourne, un effet relativiste modifie les longueurs des trajets optiques, et une différence de fréquence apparaît entre les deux signaux; cette différence, enregistrée par un photodétecteur, permet de mesurer la rotation de l’ensemble avec une très bonne précision, et une insensibilité quasi totale aux conditions ambiantes (accélérations, vibrations, variations de température), d’où le développement accéléré de ce type de gyroscope au sein de l’industrie aérospatiale.

CONT

Le gyrolaser est un oscillateur double constitué d’un laser à gaz. Sa cavité résonnante, triangulaire ou carrée, et dont les sommets sont matérialisés par des miroirs, contient du plasma(hélium-néon). Elle est parcourue par les ondes, de telle sorte que le chemin optique parcouru par les ondes soit multiple de leur longueur d’onde.

OBS

gyrolaser : terme uniformisé par le Comité d’uniformisation de la terminologie aéronautique (CUTA) - Opérations aériennes.

Espagnol

Conserver la fiche 1

Fiche 2 2002-08-26

Anglais

Subject field(s)
  • Lasers and Masers
  • Optics
  • Flight Instruments and Equipment (Aeroindustry)
CONT

Resonant Fiber - Optic Gyros. Evolved as a solid state derivative of the passive ring gyro, which makes use of a laser source external to the ring cavity. A passive resonant cavity is formed from a multi-turn closed loop of optical fiber.

Français

Domaine(s)
  • Masers et lasers
  • Optique
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

[...] signalons l'entrée en service en 1994, sur avion de transport civil, du gyromètre à fibre optique [...] Son principe de fonctionnement est voisin du gyrolaser à cavité. [...] Ce gyromètre sans gaz, ni plasma, ni pièce mécanique mobile est particulièrement robuste. [...] Un autre type de gyromètre optique est à l'étude, dit à cavité résonnante passive et constitué d’un guide d’onde en forme d’anneau. Il est toujours basé sur le principe de deux faisceaux de lumière contra-rotatifs.

OBS

Résonant, variante résonnant.

Espagnol

Conserver la fiche 2

Fiche 3 2001-09-17

Anglais

Subject field(s)
  • Optics
  • Lasers and Masers
  • Flight Instruments and Equipment (Aeroindustry)
OBS

Resonant Fiber - Optic Gyros. Evolved as a solid state derivative of the passive ring gyro, which makes use of a laser source external to the ring cavity. A passive resonant cavity is formed from a multi-turn closed loop of optical fiber.

Terme(s)-clé(s)
  • passive resonant cavity optical gyroscope
  • passive resonant cavity optic gyro
  • passive resonant cavity optic gyroscope

Français

Domaine(s)
  • Optique
  • Masers et lasers
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

[...] signalons l'entrée en service en 1994, sur avion de transport civil, du gyromètre à fibre optique [...] Son principe de fonctionnement est voisin du gyrolaser à cavité. [...] Ce gyromètre sans gaz, ni plasma, ni pièce mécanique mobile est particulièrement robuste. [...] Un autre type de gyromètre optique est à l'étude, dit à cavité résonnante passive et constitué d’un guide d’onde en forme d’anneau. Il est toujours basé sur le principe de deux faisceaux de lumière contra-rotatifs.

OBS

Résonant, variante résonnant.

Terme(s)-clé(s)
  • gyromètre à fibre optique à cavité résonnante passive
  • gyromètre à fibre optique à cavité résonante passive

Espagnol

Conserver la fiche 3

Fiche 4 2001-09-17

Anglais

Subject field(s)
  • Optics
  • Lasers and Masers
  • Flight Instruments and Equipment (Aeroindustry)
CONT

In its simplest form, the ring laser gyro (RLG) consists of a triangular block of glass drilled out for 3 helium-neon laser bores with mirrors at the 120 degree points - the corners. Counter-rotating laser beams - one clockwise (CW) and the other counter-clockwise (CCW) coexist in this resonator. At some point, a photosensor monitors the beams where they intersect.

CONT

When the RLG [ring laser gyro] is rotating, the path length around the loop is actually different depending if you measure it clockwise or counter-clockwise. This path length difference causes the counter-rotating laser beams to have a different frequency. The beat of these frequencies is detected to measure the angular rate.

Terme(s)-clé(s)
  • counter-rotating laser beams
  • counter rotating laser beams
  • counterrotating laser beams
  • contra-rotating light beams

Français

Domaine(s)
  • Optique
  • Masers et lasers
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

[...] signalons l'entrée en service en 1994, sur avion de transport civil, du gyromètre à fibre optique [...] Son principe de fonctionnement est voisin du gyrolaser à cavité. [...] Ce gyromètre sans gaz, ni plasma, ni pièce mécanique mobile est particulièrement robuste. [...] Un autre type de gyromètre optique est à l'étude, dit à cavité résonnante passive et constitué d’un guide d’onde en forme d’anneau. Il est toujours basé sur le principe de deux faisceaux de lumière contra-rotatifs.

CONT

Le principe de fonctionnement des GFO [gyromètre à fibre optique] correspond non plus à une cavité optique résonante mais à une bobine de fibre optique qui peut atteindre plusieurs kilomètres. La différence de chemin optique rencontrée par les deux ondes contra-propagatives, en présence d’une rotation suivant l’axe de la bobine, est mise en évidence par une différence de phase au point de combinaison. Il ne s’agit donc plus d’une différence de fréquence des deux ondes comme dans le cas du gyrolaser, mais d’une différence de phase.

Terme(s)-clé(s)
  • rayons contrarotatifs
  • faisceaux de lumière contra-rotatifs
  • ondes contrarotatives
  • faisceaux lumineux contrarotatifs
  • ondes contra-propagatives
  • onde contrapropagative
  • ondes contrapropagatives

Espagnol

Conserver la fiche 4

Fiche 5 2001-09-14

Anglais

Subject field(s)
  • Lasers and Masers
  • Optics
  • Aircraft Piloting and Navigation
  • Flight Instruments and Equipment (Aeroindustry)
OBS

Specialized configurations - a triple XYZ axis triangular cavity laser in a solid glass block for an optical ring laser gyro, for example - also exist but are much much less common - you probably won't find one of these at a local flea market!

Français

Domaine(s)
  • Masers et lasers
  • Optique
  • Pilotage et navigation aérienne
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Le gyrolaser est un oscillateur optique dans lequel un laser émet deux ondes progressives indépendantes qui parcourent une cavité résonnante en sens contraire l'une de l'autre. Dans les gyrolasers des centrales Sagem [...] cette cavité a la forme d’un triangle équilatéral et trois électrodes(deux anodes et une cathode) excitent un mélange d’hélium et de néon créant ainsi un milieu amplificateur. Figure 3. 82 : gyrolaser à cavité triangulaire [...] Des gyrolasers à cavité carrée ont aussi été développés.

Terme(s)-clé(s)
  • gyrolaser à cavité résonante triangulaire

Espagnol

Conserver la fiche 5

Fiche 6 2001-09-14

Anglais

Subject field(s)
  • Lasers and Masers
  • Optics
  • Aircraft Piloting and Navigation
  • Flight Instruments and Equipment (Aeroindustry)
OBS

The Canterbury Ring Laser, built in the Department of Physics principally by Morrie Poulton and Clive Rowe under the guidance of Professor Hans Bilger of Oklahoma State University, is a large laser gyroscope with an unusually high frequency resolution... The Canterbury ring system has a nearly square optical cavity with an area of 0.7547 square metres and a perimeter of 3.477 m (and so a free spectral range of 86.22 MHz).

OBS

Specialized configurations - a triple XYZ axis triangular cavity laser in a solid glass block for an optical ring laser gyro, for example - also exist but are much much less common - you probably won't find one of these at a local flea market!

Terme(s)-clé(s)
  • square optical cavity laser gyroscope

Français

Domaine(s)
  • Masers et lasers
  • Optique
  • Pilotage et navigation aérienne
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Le gyrolaser est un oscillateur optique dans lequel un laser émet deux ondes progressives indépendantes qui parcourent une cavité résonnante en sens contraire l'une de l'autre. Dans les gyrolasers des centrales Sagem [...] cette cavité a la forme d’un triangle équilatéral et trois électrodes(deux anodes et une cathode) excitent un mélange d’hélium et de néon créant ainsi un milieu amplificateur. Des gyrolasers à cavité carrée ont aussi été développés.

Espagnol

Conserver la fiche 6

Fiche 7 2001-08-23

Anglais

Subject field(s)
  • Optics
  • Lasers and Masers
  • Aircraft Piloting and Navigation
  • Ship Piloting
CONT

... the ring laser gyro concept is based on the principles of general relativity, which predict that the distance around a closed optical path in a rotating frame of reference depends on the direction the path is traversed. A beam of light traveling around the path in the direction of rotation will have to travel farther than one traveling in the opposite direction of rotation, and the pathlength difference can be used as a measure of angular rotation.

Français

Domaine(s)
  • Optique
  • Masers et lasers
  • Pilotage et navigation aérienne
  • Pilotage des navires
CONT

Application optique dans un domaine inattendu, la navigation inertielle, le gyrolaser est un nouveau gyromètre plus fiable que son prédécesseur mécanique, et particulièrement bien adapté aux conditions d’utilisation plus dures de l’avionique militaire et spatiale. [...] Principe. Effet Sagnac. L’interféromètre de Sagnac met en jeu, sur un trajet optique fermé, deux rayons lumineux se propageant en sens contraire. La rotation du bloc optique ainsi constitué introduit alors une différence de phase. Les calculs font appel à la relativité générale, et prouvent que le calcul classique est une bonne approximation. On montre ainsi que l’écart temporel DT est proportionnel à la vitesse de rotation W. La différence de chemin optique DL = c DT entre les deux rayons contrarotatifs [s’exprime dans une formule x].

CONT

Le gyrolaser est un oscillateur double constitué d’un laser à gaz. Sa cavité résonnante, triangulaire ou carrée, et dont les sommets sont matérialisés par des miroirs, contient du plasma(hélium-néon). Elle est parcourue par les ondes, de telle sorte que le chemin optique parcouru par les ondes soit multiple de leur longueur d’onde.

PHR

Trajet optique horaire, anti-horaire.

PHR

Supplément, défaut de trajet optique.

Espagnol

Conserver la fiche 7

Fiche 8 2001-06-21

Anglais

Subject field(s)
  • Lasers and Masers
  • Optics
  • Aircraft Piloting and Navigation
  • Flight Instruments and Equipment (Aeroindustry)
CONT

Specialized configurations - a triple XYZ axis triangular cavity laser in a solid glass block for an optical ring laser gyro, for example - also exist but are much much less common - you probably won't find one of these at a local flea market!

Français

Domaine(s)
  • Masers et lasers
  • Optique
  • Pilotage et navigation aérienne
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

Mon travail de thèse consiste dans un premier temps à étudier la technique de stabilisation en fréquence du laser sur une cavité triangulaire (stabilisation de l’ordre de 1E-11 lambda par rapport à la cavité de référence), ainsi que l’alignement automatique du laser sur une seconde cavité appelée «mode cleaner» permettant de sélectionner le mode fondamental du faisceau laser gaussien.

OBS

Le gyrolaser est un oscillateur optique dans lequel un laser émet deux ondes progressives indépendantes qui parcourent une cavité résonnante en sens contraire l'une de l'autre. Dans les gyrolasers des centrales Sagem [...] cette cavité a la forme d’un triangle équilatéral et trois électrodes(deux anodes et une cathode) excitent un mélange d’hélium et de néon créant ainsi un milieu amplificateur. Figure 3. 82 : gyrolaser à cavité triangulaire [...] Des gyrolasers à cavité carrée ont aussi été développés.

Terme(s)-clé(s)
  • cavité résonante triangulaire

Espagnol

Conserver la fiche 8

Fiche 9 1992-11-26

Anglais

Subject field(s)
  • Lasers and Masers

Français

Domaine(s)
  • Masers et lasers
DEF

Technique où un rayon laser YAG modèle la forme des impulsions optiques.

CONT

En juin 1989, une nouvelle génération de lasers YAG Lumonics a été introduite au Salon de Munich : il s’agit de lasers de découpe, délivrant une puissance moyenne de 1 kW. [...] La cavité résonnante(l'oscillateur) chargée de générer la lumière est associée à un amplificateur. Ici, deux barreaux de grenat d’yttrium aluminium se trouvent installés en série. On soude alors des aciers, jusqu'à 8 à 10 mm de profondeur, par superposition d’impulsions avec un taux de recouvrement de 50 à 80%. Le laser de découpe possède un faisceau de meilleure qualité, car on délaisse la fibre optique pour une optique d’usinage classique, à lentilles. Cette optique concentre le faisceau sur une tache focale de diamètre plus faible : 200 microns, alors qu'on ne descend guère au-dessous de 0, 5mm; mais qualité oblige, la puissance moyenne est ramenée à 800 W. autre nouvelle application, le pulse shaping. Une sorte de "marteau piqueur" à rayon laser qui permet de modeler la forme des impulsions optiques pour obtenir un effet de prétraitement des matériaux très réfléchissants tels que l'aluminium, ou en effet de percussion lors de l'arrivée des impulsions de forte puissance crête(22 kW au lieu de 5 kW pour le soudage et la découpe) en perçage. La durée de ces impulsions est elle-même réglable entre 0, 5 et 5 ms(Science et Technologie, 07-08. 1990, 27-28, p. 66).

Espagnol

Conserver la fiche 9

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)

Utilisez ce prototype d’intelligence artificielle pour traduire le contenu du gouvernement du Canada jusqu’au niveau Protégé B inclusivement. Réservé au personnel de certains ministères et organismes.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :