TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

CONSTANTES NUCLEAIRES [3 fiches]

Fiche 1 2017-04-20

Anglais

Subject field(s)
  • Calculating Procedures (Mathematics)
  • Nuclear Physics
CONT

The [nuclear] core codes can include evolution modules to update the composition of the fuel during the burn up. These codes solve the nuclide evolution equations … They can contain also special modules to furnish information for the definition of interpolation parameters … The multi-parameter tables are prepared by the cell codes but we need information on the power production and on the medium properties to effectuate the interpolation and to apply the cross-sections computed in cell codes. Sometimes, some codes which simulate simplified thermal hydraulic calculation are employed to feed information back to the interpolation algorithms.

Terme(s)-clé(s)
  • multiparameter table

Français

Domaine(s)
  • Procédés de calcul (Mathématiques)
  • Physique nucléaire
CONT

Les deux approximations [pour les corrections ponctuelles des opérateurs] nécessitent la présence dans les codes de calcul de cœur de sous-programmes capables […] pour le calcul des REP [réacteurs à eau pressurisée], de fournir les informations locales nécessaires à la définition des paramètres d’interpolation. En raison du couplage étroit existant entre la production de puissance et les conditions physiques des milieux dans les REP [réacteurs à eau pressurisée] (températures, densité du modérateur, etc.), ces informations sont élaborées par des fonctions des codes, simulant un calcul thermohydraulique sous forme simplifiée, ou bien elles sont transmises directement par un module de calcul thermohydraulique couplé avec le code de cœur. Les données ainsi calculées permettent l’évaluation des paramètres physiques locaux utilisés, moyennant interpolation dans les tables multiparamétrées préparées par le code de cellule pour mettre à jour, à chaque pas de temps et en chaque node, les composantes des opérateurs.

CONT

La génération des tables multiparamétrées est effectuée en faisant varier de façon couplée ou indépendante, toutes choses égales par ailleurs, un certain nombre de paramètres, choisis parmi les plus significatifs, autour du point de fonctionnement théorique retenu pour le calcul nominal des constantes nucléaires, et en recalculant les sections efficaces dans ces conditions. Le nombre de paramètres considérés dépend du niveau d’approximation choisi et des caractéristiques du code en aval. En général, pour les REP [réacteurs à eau pressurisée] sont pris en compte, a minima, les températures du combustible et du modérateur, la concentration de bore dans le modérateur et l'empoisonnement xénon. La génération de ces tables est effectuée, de façon indépendante, à toute étape d’évolution.

Terme(s)-clé(s)
  • table multi-paramétrée

Espagnol

Conserver la fiche 1

Fiche 2 2016-11-30

Anglais

Subject field(s)
  • Organizations, Administrative Units and Committees
  • Nuclear Physics
OBS

International Agency for Atomic Energy.

OBS

International Nuclear Data Committee; INDC: term and abbreviation extracted from the “Glossaire de l’énergie nucléaire” and reproduced with permission of the Organisation for Economic Co-operation and Development.

Français

Domaine(s)
  • Organismes, unités administratives et comités
  • Physique nucléaire
OBS

Comité international des constantes nucléaires : terme extrait du «Glossaire de l'énergie nucléaire» et reproduit avec l'autorisation de l'Organisation de coopération et de développement économiques.

Espagnol

Conserver la fiche 2

Fiche 3 2010-11-26

Anglais

Subject field(s)
  • Electrical Engineering
  • Radiological Physics (Theory and Application)
CONT

[Nuclear radiation detector.] Pile-Up Rejection. If two pulses arrive within the so-called measurement time (peaking time) the output pulse will have a distorted amplitude. The pile-up rejector circuit is used to prevent the measurement of these distorted pulses. The pile-up rejector is implemented by adding a fast pulse-shaping amplifier with a very short shaping time constant in parallel with the slow spectroscopy amplifier.

Terme(s)-clé(s)
  • pileup rejector circuit
  • pileup rejection system
  • pileup rejector

Français

Domaine(s)
  • Électrotechnique
  • Physique radiologique et applications
CONT

[Détecteur de rayonnements nucléaires. ] Circuit anti-empilement […] : si le temps séparant deux événements est plus court que la durée du signal en sortie d’amplificateur, ces deux signaux vont s’empiler. Pour réduire ce phénomène, on peut diminuer les constantes de temps mais on élargit la bande passante et on diminue le rapport signal/bruit. Par ailleurs avec des constantes de temps qui ne seraient plus assez grandes devant le temps de montée du signal issu du pré-amplificateur, le défaut balistique n’ est plus constant. Le rôle du circuit anti-empilement est de rejeter le signal si un deuxième événement survient dans un temps inférieur à la durée de l'impulsion.

Espagnol

Conserver la fiche 3

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :