TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

MIGRATION ELECTRIQUE [10 fiches]

Fiche 1 2017-04-13

Anglais

Subject field(s)
  • Diagnostic Procedures (Medicine)
  • Immunology
  • Veterinary Medicine
DEF

A laboratory technique in which an electric current is used to accelerate the migration of antibody and antigen through a buffered gel diffusion medium.

OBS

Antigens in a gel medium in which the pH is controlled are strongly negatively charged and will migrate rapidly across the electric field toward the anode. The antibody in such a medium is less negatively charged and will migrate in an opposite or "counter" direction toward the cathode. If the antigen and antibody are specific for each other, they combine and form a distinct precipitin line.

OBS

Used in the diagnosis of many bacterial, mycoplasma and viral infections.

Terme(s)-clé(s)
  • counter-immuno-electrophoresis
  • immuno-electro-osmophoresis
  • immuno-electroosmophoresis

Français

Domaine(s)
  • Méthodes diagnostiques (Médecine)
  • Immunologie
  • Médecine vétérinaire
CONT

Elle dérive de l'immunodiffusion double d’Ouchterlony. Un courant électrique accélère la diffusion de l'antigène et de l'anticorps l'un vers l'autre. Le pH du tampon de la gélose est choisi pour que l'antigène migre vers l'anode et l'anticorps vers la cathode. Cette technique est plus sensible que celle d’Ouchterlony. Elle est cependant plus délicate à réaliser. La migration doit être suivie d’un lavage prolongé de la plaque pour éliminer les faux arcs de précipitation, puis d’un séchage et d’une coloration par le bleu de Coomassie ou le noir amidon afin de visualiser certains arcs très fins. Des réactions d’identité peuvent être effectuées comme par la technique d’Ouchterlony, en disposant les puits en quinconce. L'électrosynérèse est utilisée, par exemple, pour la détection des anticorps spécifiques des antigènes nucléaires solubles.

CONT

Chez les animaux vivants, le diagnostic de la MA [Maladie Aléoutienne] se fait au moyen d’une analyse de sang appelée contre-immuno électrophorèse (CIE). Ce test peut également se faire à partir de sang provenant du cœur des animaux morts.

OBS

P. ex. pour le diagnostic de la maladie d’Aujezsky chez le porc.

Terme(s)-clé(s)
  • électroimmunodiffusion double

Espagnol

Campo(s) temático(s)
  • Procedimientos diagnósticos (Medicina)
  • Inmunología
  • Medicina veterinaria
Conserver la fiche 1

Fiche 2 2012-01-12

Anglais

Subject field(s)
  • Molecular Biology
  • Genetics
DEF

A method of gel electrophoresis used to separate fragments of DNA as long as several million bases by subjecting the gel to an electrical current alternately delivered from two angles in timed intervals, which minimizes diffusion of large molecules.

CONT

Pulsed field gel electrophoresis, like other DNA electrophoresis techniques, separate DNA fragments by size, using an electrical field to force fragments to move through a gel medium. The larger fragments take longer to move through the gel, so the electrophoresis process applied must not only use alternating fields but must also last longer.

Français

Domaine(s)
  • Biologie moléculaire
  • Génétique
DEF

Technique utilisée pour la séparation de molécules d’ADN de haut poids moléculaire (15 à 1000 kb).

CONT

L'électrophorèse en champ pulsé est utilisé pour séparer des fragments de taille supérieure à 20 kb. Le principe de cette électrophorèse consiste à changer l'orientation et/ou la polarité du champ électrique alternativement au cours du temps. À chaque modification du champ, la molécule d’ADN doit se réorienter parallèlement au nouveau champ. Le temps nécessaire à la réorientation est proportionnel à la longueur de la molécule. Lorsque le champ est rétabli dans son sens initial, la molécule doit une nouvelle fois se réorienter. Ces temps de réorientation provoquent un retardement de la migration nette qui est proportionnel à la taille de la molécule. Le support de migration est un gel d’agarose à 1% et la taille des fragments séparés est de l'ordre de 50 kb à qq mégabases.

Espagnol

Campo(s) temático(s)
  • Biología molecular
  • Genética
DEF

Procedimiento para separar moléculas de ADN muy grandes (de 50 kpb [mil pares de bases] a varios Mpb [millón pares de bases]) alternando de forma pulsante la dirección de la corriente eléctrica a través del gel.

Conserver la fiche 2

Fiche 3 2011-09-26

Anglais

Subject field(s)
  • Radiological Physics (Theory and Application)
CONT

Charge migration and collection. Charge mobility. If an external electric field is applied to the region in which ions or electrons exist in the gas, electrostatic forces will tend to move the charges away from their point of origin.

Français

Domaine(s)
  • Physique radiologique et applications
CONT

Détecteurs utilisés en spectroscopie alpha [...] Migration des charges : environ 10–7 s après le passage de la particule chargée, les électrons(primaires et secondaires) voient leur énergie réduite à moins de 10 eV[ électrons-volts].Ces électrons et les ions produits vont participer à l'agitation thermiquedes molécules du gaz et diffuser vers des zones de plus faible concentration. Mais, sous l'effet duchamp électrique appliqué entre les électrodes, ces charges vont dériver en directions opposées produisant un courant. La vitesse de dérive des ions dépend directement du champ électrique et de la pression [...]

Espagnol

Conserver la fiche 3

Fiche 4 2011-06-01

Anglais

Subject field(s)
  • Electrochemistry
  • Electrometallurgy
DEF

Displacement of charged constituents of a phase from one region to another of the same phase.

CONT

Charge transport occurs by an electric migration approach everywhere within a cell.

Français

Domaine(s)
  • Électrochimie
  • Électrométallurgie
DEF

Déplacement des constituants chargés d’une phase, d’une région de la phase à une autre région de cette même phase.

CONT

La migration électrique est un déplacement de particules chargées sous gradient de potentiel électrique. Le flux de migration électrique d’espèces non chargées est nul.

Espagnol

Campo(s) temático(s)
  • Electroquímica
  • Electrometalurgia
Conserver la fiche 4

Fiche 5 2010-09-03

Anglais

Subject field(s)
  • Electrokinetics
DEF

The movement of positively charged particles (cations) in a solution or suspension toward the cathode in electrophoresis.

Français

Domaine(s)
  • Électrocinétique
DEF

Migration de particules colloïdales [en suspension] en direction de la cathode sous l'action d’un courant électrique.

CONT

La cataphorèse est utilisée dans la peinture par électrodéposition.

Espagnol

Campo(s) temático(s)
  • Electrocinética
DEF

Migración hacia el cátodo de las partículas de una suspensión coloidal, bajo la acción de un campo eléctrico.

Conserver la fiche 5

Fiche 6 2008-11-20

Anglais

Subject field(s)
  • Biotechnology
CONT

To obtain optimal resolution of proteins, a “stacking” gel is poured over the top of the “resolving” gel. The stacking gel has a lower concentration of acrylamide (larger pore size), lower pH and a different ionic content. This allows the proteins in a lane to be concentrated into a tight band before entering the running or resolving gel and produces a gel with tighter or better separated protein bands.

Français

Domaine(s)
  • Biotechnologie
CONT

L'électrophorèse a pour but d’identifier les protéines présentes dans les fractions recueillies lors de la purification. Le gel de séparation est utilisé pour séparer les protéines selon leur vitesse de migration quand elles sont soumises à un champ électrique. Le gel de concentration a pour but de concentrer les protéines avant leur migration.

Espagnol

Conserver la fiche 6

Fiche 7 2008-11-20

Anglais

Subject field(s)
  • Biotechnology
CONT

To obtain optimal resolution of proteins, a "stacking" gel is poured over the top of the "resolving" gel. ... This allows the proteins in a lane to be concentrated into a tight band before entering the running or resolving gel and produces a gel with tighter or better separated protein bands.

Français

Domaine(s)
  • Biotechnologie
CONT

L'électrophorèse a pour but d’identifier les protéines présentes dans les fractions recueillies lors de la purification. Le gel de séparation est utilisé pour séparer les protéines selon leur vitesse de migration quand elles sont soumises à un champ électrique.

Espagnol

Conserver la fiche 7

Fiche 8 2006-05-09

Anglais

Subject field(s)
  • Biotechnology
DEF

Analytical or separation technique in which charged compounds are separated under the influence of an electrical field (electrophoresis) with a gel being used as the support matrix.

Français

Domaine(s)
  • Biotechnologie
DEF

Méthode de séparation des molécules fondée sur leur migration différentielle au travers d’une matrice [...] lorsqu'on applique un potentiel électrique.

Espagnol

Campo(s) temático(s)
  • Biotecnología
Conserver la fiche 8

Fiche 9 1996-02-14

Anglais

Subject field(s)
  • Electrochemistry
DEF

Portion of the module compartment fused to one cation and one anion membrane, and containing ion exchange resin. Deionization occurs within the diluting compartment.

CONT

In normal applications, several hundreds of diluting and concentrating compartments are assembled into a "membrane stack" to obtain desired water flow rate.

Français

Domaine(s)
  • Électrochimie
DEF

Compartiment, formé d’une part par une membrane échangeuse d’anions et d’autre part par une membrane échangeuse de cations, contenant un lit mélangé de résines qui abaissent la résistance de ce compartiment et facilite le processus de migration des ions sous l'effet du potentiel électrique.

OBS

Le terme «compartiment diluat» est le terme communément utilisé par les experts.

Espagnol

Conserver la fiche 9

Fiche 10 1994-09-01

Anglais

Subject field(s)
  • Physics of Solids

Français

Domaine(s)
  • Physique des solides
DEF

Sorption accompagnée d’une migration forcée des ions sous l'action d’un champ électrique.

Espagnol

Conserver la fiche 10

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :