Fiche 1 2010-07-22

Anglais

Subject field(s)
  • Pumps
  • Heating
DEF

A pump for exhausting air [or steam] or other as from an enclosed space to a desired degree of vacuum.

CONT

These same basic components may be used in the design of a vacuum or a subatmospheric system. The vacuum heating pump maintains a vacuum in the return piping under all operating conditions, assisting the supply steam in overcoming the resistance of the system piping and assuring rapid and uniform steam distribution.

CONT

Vacuum pumps are used on a system where the returns are under a vacuum. The assembly consists of a receiver, separating tank and automatic controls for discharging the condensate to the boiler. Vacuum pumps are sized in the same manner as condensate pumps for a delivery of 2.5 to 3 times the design condensing rate.

Français

Domaine(s)
  • Pompes
  • Chauffage
CONT

Chauffage à pression sous-atmosphérique. [...] Les pompes à vide sont de deux sortes : 1. les pompes à piston, activées par la vapeur, aspirantes et foulantes, et, 2. les pompes centrifuges accouplées directement à un moteur électrique.

CONT

Chauffage à vapeur sous vide. Une pompe à vide permet d’obtenir dans l’installation une pression inférieure à la pression atmosphérique [...] Le vide est parfois réalisé à l’aide d’une pompe refoulant l’eau condensée dans la chaudière et munie d’un système d’injecteurs appropriés [...]

CONT

Pour les grands édifices [...] il est difficile de placer tous les échangeurs de chaleur au-dessus du niveau d’eau du générateur ou de la tuyauterie de retour. On utilise dans ce cas une pompe à vide qui maintient une pression inférieure à la pression atmosphérique(jusqu'à 650 mm de Hg) dans la tuyauterie générale de retour [...]

Espagnol

Conserver la fiche 1

Fiche 2 2000-02-28

Anglais

Subject field(s)
  • Gas and Oil Heating
DEF

A system in which oil may be pumped completely through the circulating loop and back into the oil storage tank.

Français

Domaine(s)
  • Chauffage au gaz et au mazout
CONT

Le réservoir de fuel et le brûleur sont reliés par des tuyauteries, ce qui peut se faire de deux façons : soit avec une seule tuyauterie, soit avec deux tuyauteries [...] Dans le système à deux tuyauteries il est prévu une tuyauterie aller et une tuyauterie retour de fuel. Dans ce cas, le dégazage de l'air qui aurait pu pénétrer se fait automatiquement par la tuyauterie de retour dans le réservoir. C'est le système classique.

Espagnol

Conserver la fiche 2

Fiche 3 1990-12-30

Anglais

Subject field(s)
  • HVAC Distribution Systems
DEF

Multiblade damper to prevent outside air from passing through the unit in reverse direction when the fan is not operating.

Terme(s)-clé(s)
  • back draft damper
  • backdraft shutter

Français

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Clapet de retenue ou clapet antiretour : accessoire de tuyauterie destiné à empêcher le retour en arrière du produit qui y circule [...]

Espagnol

Conserver la fiche 3

Fiche 4 1990-01-30

Anglais

Subject field(s)
  • HVAC Distribution Systems
  • Pipes and Fittings
CONT

Rapid condensation of steam is characteristic of steam unit heaters, especially during heating-up periods. The return piping must be planned to keep the heating coil free of condensate during periods of maximum heat output, and the steam piping must be able to carry a full supply of steam to the unit to take the place of that condensed.

Français

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Tuyauterie et raccords
CONT

Comptage volumétrique et thermostatique : il est effectué par enregistrement des indications fournies, d’une part, sur le débit du fluide chauffant au moyen d’une turbine à eau et, d’autre part, sur la différence des températures entre canalisations d’aller et de retour au moyen d’un ensemble thermostatique composé d’une sonde "chaude"(sur la tuyauterie aller) et d’une sonde "froide"(sur la tuyauterie retour).

CONT

[Installations à vapeur basse pression] Le diamètre minimal couramment admis pour les tuyauteries de retour est 3/8 (12 x 17).

Espagnol

Conserver la fiche 4

Fiche 5 1990-01-29

Anglais

Subject field(s)
  • Pumps
  • Heating
CONT

Condensate return pumps are used for low pressure, gravity return heating system. They are normally of the motor driven centrifugal type and have a receiver and automatic float control. Other types of condensate return pumps are the rotary, screw, turbine and reciprocating pump. ... the condensate pump has a capacity of 2.5 to 3 times normal flow.

CONT

When the steam condensate cannot be returned by gravity to the boiler in a two-pipe [steam heating] system, an alternating return lifting trap, condensate return pump, or vacuum return pump must be used to force the condensate back into the boiler. In a condensate return pump arrangement, the return piping is arranged for the water to flow by gravity into a collecting receiver or tank, which may be located below the steam-boiler waterline.

CONT

When ... the condensate cannot be returned to the boiler by gravity ... a condensate pump [is used] ... A condensate pump must be located at the low point of return and as close to the boiler as possible.

Français

Domaine(s)
  • Pompes
  • Chauffage
CONT

Dans une telle installation, quand l'eau condensée ne peut retourner par gravité dans le générateur de vapeur, on emploie une pompe refoulante ou une pompe à vide de retour de l'eau condensée, pour introduire celle-ci sous pression dans le générateur. Dans les installations à pompe de retour de l'eau de condensation, la tuyauterie de retour est dimensionnée de manière à ce que l'eau s’écoule par gravité dans le collecteur de retour ou dans la bâche recueillant le produit de condensation

Espagnol

Conserver la fiche 5

Fiche 6 1990-01-08

Anglais

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

Gravity furnace [which burns coal, wood, oil or gas] in which the entire heat output is delivered through one opening directly above the combustion chamber. Return air enters the unit through grille work around the perimeter of the outlet grille.

CONT

Pipeless Furnaces: These are essentially gravity warm air furnaces that are not connected to ducts. The furnace is mounted directly under the space to be heated. All the air heated in its outer jacket is discharged through a register above the heat exchanger. They are used for heating small homes and other small one-story properties.

Français

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

La fournaise sans tuyauterie représente la forme la plus simple de chauffage à air chaud par gravité. L'appareil de chauffage est installé sous le plancher de la pièce habitée et l'air réchauffé est libéré par une seule bouche d’air percée au centre du plancher. L'air frais de retour pénètre dans une ouverture circulaire qui entoure la bouche d’air chaud.

OBS

Fournaise : Ce terme est considéré comme impropre par les puristes. Selon Dagenais, dans son "Dictionnaire des difficultés de la langue française du Canada", "fournaise" serait un calque de l’anglais "furnace" et nous devrions plutôt dire "chaudière" lorsque le fluide caloporteur est l’eau ou la vapeur et "générateur d’air chaud", lorsque le fluide, est l’air. Cependant, ce terme reste d’usage fréquent au Québec, autant en langue parlée qu’en langue écrite.

Espagnol

Conserver la fiche 6

Fiche 7 1976-06-19

Anglais

Subject field(s)
  • Machinery
OBS

The crankcase lubricating oil drain pipe is to be led from the sump to its respective drain tank...

Français

Domaine(s)
  • Machines
OBS

La tuyauterie de retour d’huile du carter aboutira dans la caisse de reprise...

Espagnol

Conserver la fiche 7

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2026
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

GCtraduction (accessible uniquement sur le réseau du gouvernement du Canada)