TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

CHROMATOGRAPHIE GAZEUSE [73 fiches]

Fiche 1 2023-03-30

Anglais

Subject field(s)
  • Diagnostic Procedures (Medicine)
  • Bacterial Diseases
  • Genitourinary Tract
DEF

... a test that detects alkali volatilizable amines in vaginal fluid.

OBS

The presence of alkali volatilizable amines is one of the diagnostic criteria for bacterial vaginosis.

OBS

Amines tests have been developed as practical substitutes to the highly subjective whiff test and costly analytical procedures such as high voltage electrophoresis, thin-layer chromotography and gas chromatography.

Français

Domaine(s)
  • Méthodes diagnostiques (Médecine)
  • Maladies bactériennes
  • Appareil génito-urinaire
DEF

Test utilisé pour déterminer la présence d’amines dans les sécrétions vaginales.

OBS

La présence d’amines dans les sécrétions vaginales constitue l’un des critères diagnostiques de la vaginose bactérienne.

OBS

Le test aminé est un test simple et économique(par opposition aux techniques comme la chromatographie sur couche mince et la chromatographie en phase gazeuse) qui est plus précis et moins subjectif que le test à la potasse(«whiff test»).

Espagnol

Conserver la fiche 1

Fiche 2 - données d’organisme externe 2022-06-13

Anglais

Subject field(s)
  • Compartment - National Occupational Classification (NOC)

Français

Domaine(s)
  • Tiroir – Classification nationale des professions (CNP)

Espagnol

Conserver la fiche 2

Fiche 3 2022-05-25

Anglais

Subject field(s)
  • Analytical Chemistry
  • Biotechnology
  • Pharmacology
DEF

A partition process in which the paper acts both as the support and, by virtue of the water held in its fibres, as the stationary phase.

CONT

The tendency for a compound to divide its time between two immiscible solvents (solvents such as hexane and water which won't mix) is known as partition. Paper chromatography using a non-polar solvent is therefore a type of partition chromatography.

CONT

Paper chromatography ... is used widely for qualitative identification, although quantitative analysis can be done. A sample is spotted onto a strip of filter paper with a micropipet, and the chromatogram is "developed" by placing the bottom of the paper (but not the sample spot) in a suitable solvent ... The solvent is drawn up the paper by capillary action, and the sample components move up the paper at different rates, depending on their solubility and their degree of retention by the paper.

Français

Domaine(s)
  • Chimie analytique
  • Biotechnologie
  • Pharmacologie
CONT

La phase fixe peut [...] être constituée par un liquide imprégnant un support solide ou encore par une chaîne carbonée fixée sur un support(phase greffée). Ainsi en chromatographie sur papier, la phase fixe est formée par l'eau que les molécules de cellulose du papier adsorbent, alors qu'en chromatographie en phase gazeuse, elle est constituée d’un liquide peu volatil et thermiquement stable imprégnant un granulé poreux.

Espagnol

Campo(s) temático(s)
  • Química analítica
  • Biotecnología
  • Farmacología
CONT

En el procedimiento de la cromatografía sobre papel, se vierte una gota de la solución a analizar en un papel absorbente (papel de filtro) y se deja secar; luego se sumerge el extremo de la hoja en una mezcla de solventes (alcoholes, éteres, etc.) en agua. Los solutos migran entonces por capilaridad y cada uno de ellos da una mancha propia diferentemente situada en el papel.

Conserver la fiche 3

Fiche 4 2021-02-26

Anglais

Subject field(s)
  • Physics
  • Analytical Chemistry
CONT

Pyrolysis gas chromatography mass spectrometry. Pyrolysis gas chromatography, combined predominantly with mass spectrometry, is a powerful analytical method for the categorization of polymers. Moreover, it is useful for the characterization of monomers, comonomers, additives, and impurities.

Français

Domaine(s)
  • Physique
  • Chimie analytique

Espagnol

Conserver la fiche 4

Fiche 5 2016-07-13

Anglais

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
DEF

A detector that uses a reducing flame in which individual elements give rise to characteristic colours that are measured by a photomultiplier.

CONT

The flame photometric detector (FPD) measures the fluorescence emission of hetero atoms of organic molecules subjected to combustion.

OBS

The detector is used in gas chromatography mainly to detect components that contain particular elements, e.g. phosphorous (P) and sulfur (S).

OBS

flame photometric detector: term and definition standardized by ISO in 2014.

PHR

continuous flame photometric detector, pulsed flame photometric detector

Français

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
DEF

Détecteur utilisant une flamme réductrice dans laquelle les éléments émettent une couleur caractéristique qui est mesurée par un photomultiplicateur.

OBS

Le détecteur est utilisé en chromatographie en phase gazeuse pour détecter plus particulièrement les constituants renfermant des éléments particuliers, comme par exemple, le phosphore(P) et le soufre(S).

OBS

détecteur à photométrie de flamme : terme et définition normalisés par l’ISO en 2014.

PHR

détecteur à photométrie de flamme pulsée, détecteur à photométrie de flamme soufre-phosphore

Espagnol

Campo(s) temático(s)
  • Instrumentos científicos
  • Química analítica
Conserver la fiche 5

Fiche 6 2016-06-27

Anglais

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
DEF

A detector in which hydrocarbons are burned in a hydrogen-air flame and the electrical current caused by the resulting ions is measured between two electrodes. [Definition standardized by ISO in 2014.]

DEF

A hydrogen-air diffusion flame detector that produces a signal nominally proportional to the mass-flow rate of hydrocarbons entering the flame per unit of time - generally assumed responsive to the number of carbon atoms entering the flame. [Definition officially approved by ICAO.]

OBS

The flame ionization detector is used in gas chromatography mainly to detect hydrocarbon compounds.

OBS

flame ionization detector; FID: term and abbreviation standardized by ISO in 2014.

OBS

flame ionization detector; FI-detector: terms extracted from the "Disarmament and Peace Keeping" glossary with the permission of the United Nations Office at Geneva.

OBS

flame ionization detector; FID: term and abbreviation officially approved by the International Civil Aviation Organization (ICAO).

Terme(s)-clé(s)
  • flame ionisation detector

Français

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
DEF

Détecteur dans lequel les ions résultant de la combustion des hydrocarbures dans une flamme air/hydrogène sont mesurés électriquement entre deux électrodes.

OBS

Le détecteur à ionisation de flamme est utilisé en chromatographie en phase gazeuse pour détecter plus particulièrement les composés hydrocarbonés.

OBS

détecteur à ionisation de flamme; FID : terme, abréviation et définition normalisés par l’ISO en 2014.

OBS

détecteur à ionisation de flamme; détecteur FI : termes tirés du lexique «Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

OBS

détecteur à ionisation de flamme : terme uniformisé par l’Organisation de l’aviation civile internationale (OACI).

Espagnol

Campo(s) temático(s)
  • Instrumentos científicos
  • Química analítica
DEF

Dispositivo en el que el cambio medido de la conductividad de una llama patrón (generalmente de hidrógeno) debido a la introducción de otro gas o vapor, se utiliza para detectar dicho gas o vapor.

CONT

El detector de ionización de llama (Abreviadamente DILL) es otro de los detectores más populares y sensibles. Su detectabilidad puede ser unas mil veces más baja que el de conductividad térmica.

OBS

detector de ionización de la llama; detector de la ionización de la llama; FID: término y abreviatura aceptados oficialmente por la Organización de Aviación Civil Internacional (OACI).

Conserver la fiche 6

Fiche 7 2016-03-30

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

auxiliary gases: The gases required for detector operation, e.g. hydrogen and air for flame detectors.

OBS

Gas chromatography.

OBS

auxiliary gas: The plural form of this term (auxiliary gases) and the plural definition were standardized by ISO in 2014.

Terme(s)-clé(s)
  • auxiliary gases

Français

Domaine(s)
  • Chimie analytique
DEF

Gaz nécessaire pour faire fonctionner le détecteur, par exemple l’hydrogène et l’air pour les détecteurs à flamme.

OBS

Chromatographie en phase gazeuse.

OBS

gaz auxiliaire : terme et définition normalisés par l’ISO en 2014.

Espagnol

Conserver la fiche 7

Fiche 8 2016-03-30

Anglais

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
DEF

A detector that uses a reducing reaction in which molecules give rise to characteristic luminous emissions that are measured by a photomultiplier and the associated electronic devices.

OBS

A chemiluminescence detector is used in gas chromatography mainly to detect components that contain particular elements, e.g. nitrogen (N) and sulfur (S).

OBS

chemiluminescence detector: term and definition standardized by ISO in 2014.

Français

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
DEF

Détecteur qui utilise une réaction de réduction dans laquelle des molécules émettent des rayons lumineux caractéristiques que mesurent un photomultiplicateur et les dispositifs électroniques associés.

OBS

Le détecteur à chimiluminescence est utilisé en chromatographie en phase gazeuse principalement pour détecter des constituants contenant des éléments particuliers, comme par exemple, l'azote(N) et le soufre(S).

OBS

détecteur à chimiluminescence : terme et définition normalisés par l’ISO en 2014.

Espagnol

Conserver la fiche 8

Fiche 9 2016-02-19

Anglais

Subject field(s)
  • Scientific Measurements and Analyses
  • Geochemistry
  • Environmental Studies and Analyses
  • Gas Industry
DEF

A method by which a ... sample undergoes total combustion and the specific combustion products are measured to determine the total concentration of an element in the sample, e.g. sulfur.

CONT

The available standardized methods in the field of sulfur analysis are the Wickbold combustion method for total sulfur determination (ISO 4260); the Lingener combustion method for total sulfur determination (ISO 6326-5); gas chromatography for determination of individual sulfur compounds (ISO 19739); potentiometry for determination of hydrogen sulfide, carbonyl sulfide and thiol compounds (ISO 6326-3).

OBS

combustion method: term standardized by ISO in 2014.

Français

Domaine(s)
  • Mesures et analyse (Sciences)
  • Géochimie
  • Études et analyses environnementales
  • Industrie du gaz
DEF

Méthode permettant de déterminer, par combustion complète de l’échantillon et mesurage des produits spécifiques de combustion, la concentration totale d’un élément de l’échantillon, par exemple le soufre.

CONT

Les méthodes normalisées disponibles pour la détermination du soufre sont la méthode de combustion Wickbold, pour la détermination du soufre total(ISO 4260) ;la méthode de combustion Lingener, pour la détermination du soufre total(ISO 6326-5) ;la chromatographie en phase gazeuse, pour la détermination des composés soufrés individuels(ISO 19739) ;et la potentiométrie, pour la détermination du sulfure d’hydrogène, du sulfure de carbonyle et des thiols(ISO 6326-3).

OBS

méthode par combustion : terme et définition normalisés par l’ISO en 2014.

Espagnol

Conserver la fiche 9

Fiche 10 2016-02-18

Anglais

Subject field(s)
  • Scientific Measurements and Analyses
  • Gas Industry
DEF

A method of analysis by which the components of a gas mixture are separated using gas chromatography.

OBS

The sample is passed in a stream of carrier gas through a column that has different retention properties relative to the components of interest. Different components pass through the column at different rates and are detected as they elute from the column at different times.

OBS

gas chromatographic method: term and definition standardized by ISO in 2014.

Français

Domaine(s)
  • Mesures et analyse (Sciences)
  • Industrie du gaz
DEF

Méthode d’analyse qui utilise la chromatographie en phase gazeuse pour séparer les constituants d’un mélange de gaz.

OBS

L’échantillon passe, dans un flux de gaz vecteur, à travers une colonne qui retient sélectivement les constituants recherchés. Les constituants transitent dans la colonne à des vitesses différentes et sont détectés lors de leur élution progressive en des temps différents.

OBS

méthode par chromatographie en phase gazeuse : terme et définition normalisés par l'ISO en 2014.

Espagnol

Conserver la fiche 10

Fiche 11 2012-10-02

Anglais

Subject field(s)
  • Scientific Research Facilities
  • Analytical Chemistry
CONT

... simultaneous recordings of an eight-component mixture of aromatics and n-paraffins run on an isothermal chromatograph.

Français

Domaine(s)
  • Installations de recherche scientifique
  • Chimie analytique
OBS

Chromatographie en phase gazeuse. Touzart et Matignon fabriquent plusieurs types de chromatographes(isotherme, à programmation de température, avec ou sans automatisme) destinés aux analyses de routine. Les appareils de la gamme des GC 8A s’adaptent à tous les types de colonnes, comprennent des injecteurs classiques ou on-column ainsi que des détecteurs(TCD, FID, FPD, ECD).

Espagnol

Conserver la fiche 11

Fiche 12 2012-10-02

Anglais

Subject field(s)
  • Computer Hardware

Français

Domaine(s)
  • Matériel informatique
OBS

Chromatographie en phase gazeuse. Stang Instruments a mis en marché un chromatographe(6500 HR) dont les principales caractéristiques sont les suivantes : spécial pour colonnes capillaires; injecteur à température programmée DANIPTV; régulation de température à microprocesseur; tous types de détecteurs à ionisation, avec possibilité de montage en parallèle; échantillonneurs head-space, à purge et piège, et désorbeur séquentiel automatique 50 tubes.

Espagnol

Conserver la fiche 12

Fiche 13 2012-09-28

Anglais

Subject field(s)
  • Inventory and Material Management

Français

Domaine(s)
  • Gestion des stocks et du matériel
OBS

Chromatographie en phase gazeuse. Hewlett Packard a mis sur le marché le chromatographe 5880 A qui comporte les caractéristiques suivantes : appareil à microprocesseur; possibilité de monter 4 colonnes; plusieurs types de programmation; versions suivant les types d’injection, de détection et de traitement des données; possibilité de raccordement à station de contrôle et d’acquisition Hewlett Packard.

Espagnol

Conserver la fiche 13

Fiche 14 2012-01-17

Anglais

Subject field(s)
  • Analytical Chemistry
  • Phraseology

Français

Domaine(s)
  • Chimie analytique
  • Phraséologie
OBS

Chromatographie en phase gazeuse. Finnigan Mat a mis sur le marché plusieurs modèles d’appareils dont le TSQ qui comporte les caractéristiques suivantes : ensemble plus complet, avec spectromètre de masse triple quadrupolaire ayant une chambre de collision intermédiaire permettant l'analyse en ligne chromatographie en phase gazeuse-spectrométrie de masse et spectrométrie de masse-système d’acquisition de données.

PHR

Chambre de collision intermédiaire.

Espagnol

Conserver la fiche 14

Fiche 15 2011-12-20

Anglais

Subject field(s)
  • Analytical Chemistry
  • Biological Sciences
  • Biotechnology
DEF

A form of chromatography which uses a liquid as the moving phase and a solid or a liquid on a solid support as the stationary phase.

OBS

In column chromatography, gel permeation chromatography and partition chromatography, a solid support is used as the stationary phase.

Terme(s)-clé(s)
  • gravity-flow liquid chromatography
  • column liquid chromatography

Français

Domaine(s)
  • Chimie analytique
  • Sciences biologiques
  • Biotechnologie
DEF

Méthode physique dans laquelle les composants à séparer sont répartis en deux phases : une «phase stationnaire», constituée d’un lit de matériaux au travers duquel s’infiltre une «phase mobile».

OBS

On distingue différents modes suivant la nature de la phase stationnaire et le processus de séparation.

CONT

La chromatographie en phase liquide(CPL), un moment éclipsée par la chromatographie en phase gazeuse(CPG), a fait des progrès considérables grâce à la miniaturisation des colonnes et à la détection en continu des fractions. [...] Toutes les opérations peuvent être automatisées dans le cas d’analyses de routine. Les quantités analysées sont de l'ordre du milligramme et l'efficacité varie entre 1 000 et 10 000 plateaux théoriques; sur des colonnes appropriées on sépare par exemple tous les amino-acides naturels, alors des quantités de substance aussi faibles que 10-12 g peuvent être décelées.

CONT

Dans le chapitre chromatographie en phase liquide, on distingue : la chromatographie sur colonne (CPL) : le substrat actif est tassé dans un tube [...], si ce substrat est un gel [...] : c’est la chromatographie sur gel perméable [...]

CONT

Chromatographie en phase liquide [...] L’appareil est constitué d’une colonne en acier inoxydable d’une longueur de l’ordre de 200 mm et de diamètre inférieur à 4 mm [...] Cette colonne est précédée d’une pompe à haute pression, permettant d’injecter le solvant sous une pression de plusieurs dizaines de bars. Des microvannes assurent l’introduction de quelques microlitres de solution à analyser, en tête de colonne.

PHR

Chromatographie en phase liquide variante sous pression.

Espagnol

Campo(s) temático(s)
  • Química analítica
  • Ciencias biológicas
  • Biotecnología
DEF

Método cromatográfico basado en la separación de los componentes de una mezcla en solución por adsorción selectiva.

Conserver la fiche 15

Fiche 16 2011-09-21

Anglais

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
  • Biotechnology
DEF

The tube and the stationary phase contained within, through which the mobile phase passes.

CONT

A chromatographic column, usually made of glass, is held vertically and is uniformly packed with a solvent. The sample is usually applied to the top, and the chromatogram is developed by passing one or several solvents through the porous bed from top to bottom.

OBS

A cylindrical column, used in chromatography, to hold a solid adsorbent, support, or a liquid stationary phase, and through which the mobile phase passes.

OBS

chromatographic column: term extracted from the "Disarmament and Peace Keeping" glossary with the permission of the United Nations Office at Geneva.

PHR

Column flowrate.

PHR

Dummy, high performance, large-bore, narrow-bore, symmetrical column.

Français

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
  • Biotechnologie
DEF

Tube de diamètre et longueur variables, en verre, métal, ou autre substance, à l’intérieur duquel s’opèrent les séparations chromatographiques.

CONT

Une colonne de chromatographie en phase gazeuse classique est un tube en acier inoxydable, en verre ou en nickel, d’un diamètre intérieur de l, 5 à 4mm et d’une longueur de 0, 5 à 6 m. Ses dimensions obligent en général à lui donner une forme coudée, souvent hélicoïdale.

OBS

colonne chromatographique : terme tiré du lexique «Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

PHR

La colonne se charge.

PHR

Soumettre la colonne à une percolation.

PHR

Commutation, effet extra, efficacité, extrémité, longévité, mise en équilibre, mise en série, optimisation, rayon d’enroulement, remplissage, tassement, température affichée, température contrôlée, tête, volume mort (de, d’une, des, de la) colonne.

PHR

Colonne analytique, classique, métallique, montée verticalement, moyennement chargée, perméable aux gaz.

PHR

Post-, pré-colonne.

Terme(s)-clé(s)
  • colonne séparatrice

Espagnol

Campo(s) temático(s)
  • Instrumentos científicos
  • Química analítica
  • Biotecnología
DEF

Aparato a modo de [tubo que se utiliza] para la separación de uno o más componentes de una mezcla física mediante un relleno de material adsorbente; sus distintos componentes quedan retenidos preferentemente según diferentes velocidades de adsorción, produciéndose una separación.

CONT

La fase móvil de una columna cromatográfica está constituida por un líquido.

Conserver la fiche 16

Fiche 17 2011-07-15

Anglais

Subject field(s)
  • Trade Names
  • Chemical Elements and Compounds
OBS

Tradename for polyethylene glycols and methoxypolyethylene glycol porous polymer resins; they are available in various molecular weights and are used as liquid phase support coatings in gas chromatography.

OBS

Use: Water-soluble lubricants, solvents for dyes, resins, proteins; plasticizers ...; cosmetics and pharmaceuticals ...

OBS

Carbowax®: A trademark of Union Carbide Corp.

Terme(s)-clé(s)
  • Carbowax

Français

Domaine(s)
  • Appellations commerciales
  • Éléments et composés chimiques
OBS

Nom de commerce de résines poreuses à base de polyéthylèneglycol et de méthoxy-polyéthylèneglycol; elles sont vendues en différentes masses moléculaires [...] et sont utilisées comme revêtement du support de phase liquide en chromatographie gazeuse.

OBS

Nom générique de divers polyglycols employés comme excipients en pharmacie et en cosmétique.

OBS

Carbowax® : Marque de commerce de la société Union Carbide Corp.

Terme(s)-clé(s)
  • Carbowax

Espagnol

Conserver la fiche 17

Fiche 18 2011-06-23

Anglais

Subject field(s)
  • Chemistry
  • Applications of Electronics
DEF

A detector which uses low-energy electrons from either a tritium or Ni source, to ionize the carrier gas in an ionization chamber, at a potential just strong enough for the collection of all the free electrons produced.

OBS

electron capture detector; ECD: term and abbreviation extracted from the "Disarmament and Peace Keeping" glossary with the permission of the United Nations Office at Geneva.

Terme(s)-clé(s)
  • EC detector

Français

Domaine(s)
  • Chimie
  • Applications de l'électronique
DEF

Détecteur utilisé en chromatographie gazeuse; les composés ayant un groupement électro-négatif ont tendance à capturer les électrons pour former des ions négatifs lorsqu'ils sont exposés à une source d’électrons de faible énergie; les ions négatifs sont entraînés dans le gaz vecteur, puis sont détectés par la réduction de courant qu'ils provoquent sur une électrode.

OBS

détecteur à capture d’électrons; DCE : terme et abréviation tirés du lexique «Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Espagnol

Conserver la fiche 18

Fiche 19 2011-05-31

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

The peak relating to the presence of small amounts of air during the sample injection.

Français

Domaine(s)
  • Chimie analytique
DEF

En chromatographie en phase gazeuse, le pic souvent provoqué par l'entrée de faibles quantités d’air au moment de l'injection de l'échantillon.

Espagnol

Conserver la fiche 19

Fiche 20 2011-04-04

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

An instrument which responds to density changes in the gas stream, directly related to the molecular weights. Several forms of gas density balance have been developed since this type of detector was first introduced by Martin and James. Improvements in instrumentation have led to a revival of interest in it as a detector system suitable for molecular-weight studies. The density changes are measured by means of a form of U-tube, one limb of which contains pure carrier gas and the other column effluent gas. An anemometer situated between the two limbs detects and measures any density difference. Using nitrogen or argon carrier gas the limit of detection is 0.4 μg, response is linear with concentration, and it can be used for molecular weight determinations for values below 200 and for percentage composition studies.

Terme(s)-clé(s)
  • James Martin gas density balance

Français

Domaine(s)
  • Chimie analytique
CONT

La balance à densité gazeuse est un des premiers détecteurs utilisés en chromatographie en phase gazeuse [.... ] Le gaz de référence [...] est divisé en deux flux et passe sur les éléments chauffants placés dans un pont de Wheatstone. Le gaz vecteur sortant de la colonne entre dans le détecteur [...] puis se divise également en deux flux. La sortie est commune. S’ il ne sort de la colonne que le gaz vecteur pur, les débits dans les branches sont identiques [.... ] Le pont de Wheatstone est équilibré. Lorsqu'un soluté est élué de la colonne, et si sa densité est différente de cette du gaz vecteur [...], [il] en résulte une variation des débits qui se traduit par une variation de la température des filaments et donc par un déséquilibre du pont de Wheatstone. La réponse du détecteur est proportionnelle à la variation de la densité du gaz vecteur induite par la présence du soluté.

OBS

Peu sensible (du même ordre que le catharomètre à filaments), la balance à densité gazeuse a l’avantage d’être un détecteur universel, non destructif, et d’être le seul détecteur dont la réponse puisse être calculée rigoureusement à partir des formules chimiques des solutés qui le traversent. Pour ces raisons, elle a son utilité dans les analyses industrielles en ligne.

Espagnol

Conserver la fiche 20

Fiche 21 2006-04-03

Anglais

Subject field(s)
  • Analytical Chemistry
  • Scientific Instruments
  • Scientific Measurements and Analyses
DEF

A type of detector in which a beam of ultraviolet light is slit into two, one to pass through a reference cell and the other through the sample cell to separate photocells arranged to give the value for the sample absorption.

Français

Domaine(s)
  • Chimie analytique
  • Instruments scientifiques
  • Mesures et analyse (Sciences)
OBS

ultraviolet : Cette graphie, puisée des Rectifications de l’orthographe recommandées par le Conseil supérieur de la langue française, est attestée dans le Petit Robert (2006).

OBS

Le premier équivalent proposé dans SECHR est tiré d’un article intitulé :«Analyse d’huiles essentielles de lavandins par chromatographie en phase gazeuse après préfractionnement par chromatographie liquide à haute performance», publié dans Rivista italiana-essenze, profumi, piante officinali, aromatizzanti, syndits, saponi, cosmetici, aersols, 61 : 7, 1979, p. 302-310.

OBS

Le deuxième terme proposé dans SECHR est tiré d’un article intitulé : «La chromatographie d’affinité» signé et publié dans Lyon pharmaceutique, 26 : 1, 1975, p. 27-34.

OBS

Le troisième terme proposé dans SECHR est tiré d’un article intitulé : «Détection du beurre de karité dans le beurre de cacao», et publié dans Oléagineux, 34 : 8-9, 1979, p. 405-409.

Terme(s)-clé(s)
  • détecteur ultraviolet
  • détecteur à absorbance ultraviolet

Espagnol

Conserver la fiche 21

Fiche 22 2005-11-22

Anglais

Subject field(s)
  • Scientific Measurements and Analyses
  • Analytical Chemistry
CONT

Although real-life gas chromatography analysis is a complex process depending on numerous factors such as molecular volume, chemical and physical properties, the form of the analyzed molecules, the temperature of the process, the adsorption abilities, other properties of the matrix, etc., the separation for many compounds depends on differences in boiling points.

Français

Domaine(s)
  • Mesures et analyse (Sciences)
  • Chimie analytique
Terme(s)-clé(s)
  • analyse de chromatographie en phase gazeuse

Espagnol

Conserver la fiche 22

Fiche 23 2004-08-27

Anglais

Subject field(s)
  • Measuring Instruments
  • Environmental Studies and Analyses
  • Analytical Chemistry
CONT

... sampling into silica gel tube, 2,4-dinitrophenylhydrazine impregnated passive diffusion badge or filter cassette and subsequent gas chromatographic or high performance liquid chromatographic analysis provides more accurate determination of airborne glutaraldehyde concentration ...

CONT

Nitschke et al (1998) analysed indoor nitrogen dioxide levels by selecting a cohort of 129 asthmatics and ensuring they wore diffusion badge monitors while indoor gas appliances are being used, which is seen as potentially the greatest period of exposure. Levels were expressed at time-average nitrogen dioxide concentration, because daily badge exposure times differed (mean 4.5 hours, sd 2.4).

CONT

The exposure of each child to nitrogen dioxide both at home and in the classroom was measured using passive diffusion badge monitors.

Français

Domaine(s)
  • Appareils de mesure
  • Études et analyses environnementales
  • Chimie analytique
CONT

Les cétones sont piégées sur un badge à diffusion passive ou dans un tube rempli de charbon actif [...] et dosées par chromatographie en phase gazeuse avec détection par ionisation de flamme avec désorption sur charbon actif [...]

CONT

Le département «Hygiène - Toxicologie - Détection» dispose d’une gamme complète pour le contrôle de l’air de lieu de travail, l’air intérieur de l’habitat et l’air ambiant en gaz toxique, poussières, aérosol, métaux lourds, silicie, HAP, BTX, amiante, fibre, aérobiocontaminant, bactérie, organisme microbiologique, moisissure, pollen, échantillonneur individuel (badge passif GABIE et CIP10M pour les polluants microbiologiques (spore, endotoxine), bactérie, pollen, moisissures, capteur individuel de poussières CIP10, pompe de prélèvement), station et pompe de prélèvement pour l’air ambiant (PM10, PM2.5), détecteur de gaz toxique, ainsi que tous les accessoires nécessaires pour piéger du polluant lors de prélèvement [...]

Espagnol

Conserver la fiche 23

Fiche 24 2004-04-26

Anglais

Subject field(s)
  • Chemical Engineering

Français

Domaine(s)
  • Génie chimique
CONT

Dosage des alcaloïdes dans le tabac entier. [...] L'analyse est réalisée par chromatographie en phase gazeuse(CPG), à l'aide d’une colonne capillaire en silice fondue et d’une détecteur thermoïonique spécifique(DTS). L'extraction de vingt-cinq milligrammes de tabac lyophilisé et moulu est réalisée avec 1, 0 mL d’une solution méthanolique de KOH(contenant du 2, 4-dipyridyle comme étalon interne), dans un bain ultrasonique pendant trois heures.

CONT

Dosages des ions magnésium par spectrophotométrie. [...] En mélangeant, en solution méthanolique, les ions magnésium et l’émodine, on aura formation d’un complexe coloré.

Espagnol

Conserver la fiche 24

Fiche 25 2003-11-07

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A form of gas chromatography in which the moving phase is a gas and the stationary phase is a surface-active sorbent (charcoal, silica gel, or activated alumina). The separation is achieved by adsorption of the components of a sample.

OBS

The physical states of the mobile and stationary phases give rise to four basic types of chromatography: gas-liquid chromatography (GLC), gas-solid chromatography (GSC), liquid - liquid chromatography (LLC), and liquid-solid chromatography (LSC). Of the four basic types of chromatography, the two gas systems are independent and not subject to subdivisions. Thus the terms "gas-liquid chromatography" and "gas-solid chromatography" adequately identify the techniques involved. The liquid systems are not as easily described and are not mutually exclusive, which can lead to considerable confusion.

Terme(s)-clé(s)
  • gas adsorption chromatography
  • solid gas chromatography

Français

Domaine(s)
  • Chimie analytique
DEF

Chromatographie en phase gazeuse dans laquelle la phase fixe est constituée par un adsorbant solide.

OBS

Dans cette définition, le premier mot spécifie la nature de la phase mobile et le second la phase stationnaire. En chromatographie gazeuse, la distinction entre gaz-solide peut paraître obscure : des liquides peuvent être employés pour modifier les phases stationnaires solides et les supports solides utilisés pour retenir les phases stationnaires liquides qui peuvent affecter le processus chromatographique. Dans un classement selon la nature des phases, le terme relatif à l'effet prédominent doit être choisi.

OBS

«Chromatographie gaz-solide» a été normalisé par l’AFNOR.

Terme(s)-clé(s)
  • chromatographie d’adsorption des mélanges gazeux
  • chromatographie gaz solide

Espagnol

Campo(s) temático(s)
  • Química analítica
DEF

Cromatografía de gases en la que la fase estacionaria es un sólido adsorbente.

Conserver la fiche 25

Fiche 26 2003-11-07

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A form of gas chromatography in which the fixed phase (column packing) is a liquid solvent distributed on an inert solid support.

OBS

The physical states of the mobile and stationary phases give rise to four basic types of chromatography: gas-liquid chromatography (GLC), gas-solid chromatography (GSC), liquid-liquid chromatography (LLC), and liquid-solid chromatography (LSC). Of the four basic types of chromatography, the two gas systems are independent and not subject to subdivisions. Thus the terms "gas-liquid chromatography" and "gas-solid chromatography" adequately identify the techniques involved. The liquid systems are not as easily described and are not mutually exclusive, which can lead to considerable confusion.

PHR

Open tubular gas-liquid chromatography.

Français

Domaine(s)
  • Chimie analytique
DEF

Chromatographie en phase gazeuse dans laquelle la phase fixe est constituée par un liquide imprégnant un support solide inerte.

OBS

Dans cette définition et dans celle de la chromatographie gaz-solide, le premier mot spécifie la nature de la phase mobile et le second la phase stationnaire. Les phases stationnaires liquides sont déposées sur des solides, mais le support solide affecte le processus chromatographique. Dans un classement selon la nature des phases, le terme relatif à l’effet prédominant doit être choisi.

OBS

chromatographie gaz-liquide : terme normalisé par l’AFNOR.

Espagnol

Campo(s) temático(s)
  • Química analítica
DEF

Cromatografía de gases en la que la fase estacionaria es un líquido soportado en un sólido.

Conserver la fiche 26

Fiche 27 2003-11-06

Anglais

Subject field(s)
  • Analytical Chemistry
  • Scientific Measurements and Analyses
  • Environmental Studies and Analyses
  • Biotechnology
DEF

A separation technique involving passage of a gaseous moving phase through a column containing a fixed phase. ... Gas chromatographic separations are achieved by selective retardation exerted by the fixed phase ...

CONT

Oil analysis involves three levels of laboratory activity: sample preparation and clean up, basic identification, and final comparison. ... Typical analyses include observation of solubility in organic solvents, ... [and] gas chromatography ... Oils and oil/water samples may be analysed to identify the type of spilled petroleum product or to establish similarity between samples collected from the environment and from suspected sources.

OBS

The term vapour phase chromatography is no longer used for what is now called gas chromatography.

OBS

[Refers to] gas-liquid or gas-solid chromatography.

Terme(s)-clé(s)
  • vapor phase chromatography

Français

Domaine(s)
  • Chimie analytique
  • Mesures et analyse (Sciences)
  • Études et analyses environnementales
  • Biotechnologie
DEF

Méthode de séparation dont les principes généraux sont les mêmes que ceux énoncés pour la chromatographie en général, c’est-à-dire fondés sur la migration différentielle des constituants du mélange à analyser au travers d’un substrat choisi. La particularité du procédé est d’opérer en totalité sur des produits volatilisés, ce qui implique de maintenir une température minimale convenable, mais sans qu’il y ait volatilisation du substrat, et de travailler en circuit étanche au gaz.

CONT

La chromatographie en phase gazeuse est une méthode de séparation des composés gazeux ou susceptibles d’être vaporisés par chauffage sans décomposition. Elle permet ainsi l'analyse de mélanges éventuellement très complexes dont les constituants peuvent différer d’une façon considérable par leur nature et leur volatilité. La chromatographie en phase gazeuse appartient à l'ensemble des techniques chromatographiques dont la chromatographie en phase liquide à hautes performances et la chromatographie en couche mince sont d’autres exemples importants.

OBS

Des différentes techniques chromatographiques utilisées pour l'identification des polluants pétroliers [...] [la] chromatographie gazeuse [...] s’est avérée la plus efficace.

OBS

L’expression «chromatographie en phase vapeur» est mauvaise. Condamnée par les bons auteurs depuis plus de vingt ans, elle est encore trop souvent rencontrée.

Espagnol

Campo(s) temático(s)
  • Química analítica
  • Medición y análisis (Ciencias)
  • Estudios y análisis del medio ambiente
  • Biotecnología
DEF

Sistema de separación de los componentes de una mezcla entre sí por volatilización de la muestra en una corriente de gas portador.

Conserver la fiche 27

Fiche 28 2003-09-08

Anglais

Subject field(s)
  • Analytical Chemistry
  • Biotechnology
CONT

Silica Gel Column Chromatography. ... Getting reproducibility when doing silica gel (or alumina) separations with column chromatography can be a problem. If you do not carefully control the water/moisture content of the silica gel and the mobile phase, moisture is added to or removed from the silica gel during the separation. This results in retention times that either increase (with water addition to the silica gel) or decrease (with water loss from the silica gel). ... The reseacher attempting to optimize the flash chromatography of new compounds should investigate the effect of moisture on the separation being attempted. Various glass chromatographic columns containing silica gel with different amounts of moisture can be run side by side to see which column produces the optimum results.

Français

Domaine(s)
  • Chimie analytique
  • Biotechnologie
CONT

Les phospholipides sont séparés des autres lipides par chromatographie sur colonne de gel de silice et analysés par chromatographie quantitative en couche mince haute performance (densitométrie).

CONT

La séparation des saponines est très délicate. Pendant longtemps les méthodes chromatographiques dites classiques ont été utilisées, telle la chromatographie sur papier, la chromatographie sur couche mince de silice ou de cellulose (CCM) et la chromatographie sur la colonne de gel de silice.

CONT

Isolement de la fraction d’hydrocarbures de stérols par chromatographie sur colonne de gel de silice imprégné de nitrate d’argent et analyse par chromatographie en phase gazeuse sur colonne capillaire.

Espagnol

Conserver la fiche 28

Fiche 29 2003-07-14

Anglais

Subject field(s)
  • Chemical Elements and Compounds
  • Chemistry
CONT

Short-chain aldehydes are produced from fatty hydroperoxides but are also found in vegetals. Long-chain aldehydes occur in free form but are frequently included in complex lipids in the form of vinyl ether (plasmalogen analogs of glycerides or phospholipids).

CONT

The bioluminescent reaction of luciferase isolated from "Vibrio harveyi," strain M17, was initiated by mixing the intermediate luciferase-bound flavin-4alpha-hydroperoxide, purified in advance, with a long chain aldehyde (dodecanal or octanal) at -4°C.

Français

Domaine(s)
  • Éléments et composés chimiques
  • Chimie
CONT

Mise au point d’une technique de dosage des aldéhydes à longue chaîne dans les milieux biologiques par chromatographie en phase gazeuse couplée à la spectrométrie de masse.

Espagnol

Conserver la fiche 29

Fiche 30 2002-03-21

Anglais

Subject field(s)
  • Analytical Chemistry
  • Biotechnology
DEF

A liquid which is relatively nonvolatile at the column temperature and is sorbed on the solid support (employed in gas-liquid and liquid-liquid chromatography) where it acts as a solvent for the sample. The separation achieved differs with differences in solutility of the various components of the sample in the liquid phase.

OBS

Thin-film liquid stationary phases can be prepared for separation by liquid-liquid partition chromatography. The film, commonly water, is supported on materials such as silica gel or diatomaceous earth, as in column chromatography. Either silica gel or diatomaceous earth may be silanized to convert the surfaces to nonpolar methyl groups for reversed-phase thin-layer chromatography.

PHR

Nonpolar, polar liquid phase.

Français

Domaine(s)
  • Chimie analytique
  • Biotechnologie
DEF

En chromatographie gazeuse, liquide dont la tension de vapeur est relativement basse à la température de la colonne, qui est adsorbé sur le support solide et qui joue le rôle de solvant vis-à-vis de l'échantillon. La séparation repose sur la différence de solubilité des différents constituants de l'échantillon dans la phase liquide.

Espagnol

Campo(s) temático(s)
  • Química analítica
  • Biotecnología
Conserver la fiche 30

Fiche 31 2002-02-19

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
OBS

Reproduit du lexique «Disarmament and Peace Keeping/Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Terme(s)-clé(s)
  • chromatographie gazeuse à haute résolution

Espagnol

Campo(s) temático(s)
  • Química analítica
Conserver la fiche 31

Fiche 32 2001-01-24

Anglais

Subject field(s)
  • Analytical Chemistry
  • Scientific Instruments
  • Scientific Measurements and Analyses
DEF

A modified flame ionization detector in which the hydrogen flame is burnt at a jet with an alkali metal salt tip or with the alkali metal salt as a pellet just above the jet.

OBS

nitrogen phosphorous detector; NPD: term and abbreviation extracted from the "Disarmament and Peace Keeping" glossary with the permission of the United Nations Office at Geneva.

Terme(s)-clé(s)
  • alkalimetalflame ionization detector

Français

Domaine(s)
  • Chimie analytique
  • Instruments scientifiques
  • Mesures et analyse (Sciences)
OBS

Le premier équivalent proposé dans SECHR est tiré d’un ouvrage intitulé :«Manuel pratique de chromatographie en phase gazeuse» de J. Tranchant et coll. publié chez Masson, Paris, 2e édition, 1968, p. xi-178.

OBS

Le deuxième équivalent proposé dans SECHR est tiré d’un article intitulé : «Méthodes de contrôle de la pollution des eaux. Les pesticides et leur détermination dans les eaux de surface», signé par J. Lamathe, G. Maire, Ch. Magurno, paru dans la Tribune de CEBEDEAU, 34 : 446, 1981, p. 15-50.

OBS

détecteur azote-phosphore; détecteur thermo-ionique : terme(s) tiré(s) du lexique «Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Terme(s)-clé(s)
  • DTI

Espagnol

Conserver la fiche 32

Fiche 33 2000-09-12

Anglais

Subject field(s)
  • Analytical Chemistry
  • Peace-Keeping Operations
  • Arms Control
OBS

e.g. gas chromatography - mass spectrometry (GC-MS); gas chromatography - Fourier Transform Infrared chromatography (GC-FTIR)

Français

Domaine(s)
  • Chimie analytique
  • Opérations de maintien de la paix
  • Contrôle des armements
OBS

chromatographie en phase gazeuse-spectrométrie de masse(CPG-SM) ;chromatographie en phase gazeuse-chromatographie infrarouge à transformée de Fourier(CPG-IRTF), par exemple

OBS

Reproduit du lexique «Disarmament and Peace Keeping/Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Espagnol

Conserver la fiche 33

Fiche 34 2000-07-26

Anglais

Subject field(s)
  • Processing of Mineral Products
  • Mineral Processing (Metallurgy)
  • Cheese and Dairy Products
  • Analytical Chemistry
DEF

An instrument designed to take samples of gases as a predetermined point during an explosion or preceding or following it, as desired.

Français

Domaine(s)
  • Préparation des produits miniers
  • Minéralurgie (Métallurgie)
  • Laiterie, beurrerie et fromagerie
  • Chimie analytique
OBS

Chromatographie en phase gazeuse. Le modèle 3 000 fabriqué par Varian S. A. comprend les caractéristiques suivantes : appareil simple ou double colonnes, remplies, semicapillaires ou capillaires; injecteurs(classique, split-splitless, on-column) ;détecteurs(TCD, FID, ECD, NPD, FPD) ;échantillonneurs automatiques à volume programmable en mode «Sandwich» avec rinçage dynamique; programmation du four 4 rampes; contrôle total par microprocesseur.

PHR

échantillonneur automatique à volume programmable en mode Sandwich, échantillonneur automatique avec rinçage dynamique.

Espagnol

Campo(s) temático(s)
  • Preparación de los productos mineros
  • Explotación de minerales (Metalurgia)
  • Productos lácteos
  • Química analítica
Conserver la fiche 34

Fiche 35 2000-05-25

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
OBS

Reproduit du lexique «Disarmament and Peace Keeping/Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Espagnol

Conserver la fiche 35

Fiche 36 2000-05-25

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
OBS

Reproduit du lexique «Disarmament and Peace Keeping/Désarmement et Maintien de la Paix» avec l’autorisation de l’Office des Nations Unies à Genève.

Espagnol

Conserver la fiche 36

Fiche 37 1999-09-30

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A sample injector by means of which the eluent (carrier gas) may be temporarily diverted through a sample chamber so that the sample is carried to the column.

OBS

The operation of the device differs from that of sample loops in which the sample itself is rotated into the gas stream.

Français

Domaine(s)
  • Chimie analytique
DEF

En chromatographie gazeuse, [...] injecteur d’échantillon qui permet de faire passer temporairement l'éluant(le gaz vecteur) par une chambre à échantillon, de façon à introduire un échantillon dans la colonne.

Espagnol

Conserver la fiche 37

Fiche 38 1999-05-27

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

The fraction (1 - R) of a component in the stationary phase divided by the fraction (R) in the mobile phase ...

OBS

"Mass distribution factor" is recommended in preference to the term capacity factor frequently used in the chromatographic literature.

OBS

The distribution ratio is defined as "K" in chromatography.

OBS

Dm should be read as Dm.

Français

Domaine(s)
  • Chimie analytique
DEF

Fraction (1 - R) d’un composant dans la phase stationnaire divisée par sa fraction (R) dans la phase mobile [...]

OBS

Il est très rare qu’un solvant unique permette d’aboutir à des valeurs des facteurs de capacité convenables et surtout à une résolution optimale (on ne peut observer qu’une variation discontinue des facteurs de capacité et de la résolution lorsque l’on passe d’un solvant à un autre). C’est pourquoi on utilise très souvent des mélanges de solvants et plus particulièrement des mélanges binaires.

OBS

Le terme «coefficient de distribution massique» est recommandé de préférence à «facteur de capacité» fréquemment employé dans la littérature en chromatographie en phase gazeuse.

OBS

Dm doit se lire Dm.

PHR

Facteur de capacité des solutés.

Espagnol

Conserver la fiche 38

Fiche 39 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 39

Fiche 40 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 40

Fiche 41 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 41

Fiche 42 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 42

Fiche 43 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry
Terme(s)-clé(s)
  • programmed pressure gas chromatography
  • pressure programmed gas chromatography

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 43

Fiche 44 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 44

Fiche 45 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 45

Fiche 46 1999-04-26

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 46

Fiche 47 1999-04-12

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

The area enclosed between the peak and the peak base.

CONT

[Analysis of environmental and material samples from spill sites.] A suitable volume is injected into an ion chromatograph. Peak areas and retention times are used to identify and quantify species of interest relative to standards.

OBS

In gas chromatography.

PHR

Corrected peak area.

Français

Domaine(s)
  • Chimie analytique
CONT

[Chromatographie d’échange d’ions.] Une quantité adéquate du mélange est injectée dans un chromatographe d’échange d’ions. Les aires des pics et les temps de rétention servent à quantifier et à identifier les substances étudiées, en fonction des étalons.

CONT

Il y a proportionnalité entre l’aire des pics et les quantités injectées.

OBS

Chromatographie en phase gazeuse.

Espagnol

Conserver la fiche 47

Fiche 48 1998-05-19

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

The gas chromatographic separation of components of a mixture on such a scale as to allow the isolation and collection of the components.

Français

Domaine(s)
  • Chimie analytique
CONT

Nous avons soumis une série d’échantillons à la chromatographie en phase gazeuse préparative.

Espagnol

Conserver la fiche 48

Fiche 49 1998-05-14

Anglais

Subject field(s)
  • Analytical Chemistry
Terme(s)-clé(s)
  • gas chromatography-mass spectrometry combination
  • combined gas chromatography-mass spectrometry

Français

Domaine(s)
  • Chimie analytique
CONT

Les difficultés du couplage CG-SM proviennent, d’une part, des pressions différentes à l’intérieur de la colonne chromatographique et dans l’enceinte du spectromètre de masse et, d’autre part, de l’harmonisation du temps qui mesure la largeur du pic chromatographique en sortie de colonne avec celui requis pour l’enregistrement du spectre de masse.

OBS

La combinaison entre la chromatographie en phase gazeuse et la spectrométrie de masse CG-SM(en anglais GC-MS) est une des meilleures solutions [...] Développé à partir de 1960, le couplage CG-SM a connu depuis une progression rapide et les problèmes techniques sont bien maîtrisés depuis le début des années 1980.

Espagnol

Conserver la fiche 49

Fiche 50 1998-05-14

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A form of gas chromatography used in the laboratory in which compounds may be converted to other related compounds in a reaction zone ahead of the chromatograph column.

Terme(s)-clé(s)
  • reaction gaz chromatography

Français

Domaine(s)
  • Chimie analytique
Terme(s)-clé(s)
  • chromatographie gazeuse à réaction

Espagnol

Conserver la fiche 50

Fiche 51 1998-03-03

Anglais

Subject field(s)
  • Medical Instruments and Devices
  • Special-Language Phraseology

Français

Domaine(s)
  • Instruments et appareillages médicaux
  • Phraséologie des langues de spécialité

Espagnol

Conserver la fiche 51

Fiche 52 1997-03-26

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

[In gas chromatography], the flowrate which is normally specified at the column temperature and outler pressure, although the measurement may be made at ambient temperature and must be corrected accordingly (and possibly also for water vapour present in the flowmeter).

Français

Domaine(s)
  • Chimie analytique
DEF

[En chromatographie gazeuse], débit[...] normalement donné à la température de la colonne et sous la pression de sortie bien que la mesure puisse être effectuée à la température ambiante et doive alors être corrigée.(De même faut-il corriger pour la vapeur d’eau éventuellement présente dans le débitmètre).

Espagnol

Conserver la fiche 52

Fiche 53 1997-02-21

Anglais

Subject field(s)
  • Canadian General Standards Board (CGSB) Standards
OBS

Standard number: CAN/CGSB-3.0, 14.3-94

Français

Domaine(s)
  • Normes de l'Office des normes générales du Canada (ONGC)
OBS

Numéro de norme : CAN/CGSB-3.0, 14.3-94

Espagnol

Conserver la fiche 53

Fiche 54 1996-11-21

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

[In gas chromatography], uniform distribution of the eluent vapour throughout the chamber prior to chromatography.

Français

Domaine(s)
  • Chimie analytique
DEF

[En chromatographie gazeuse], chambre dans laquelle on réalise une répartition uniforme de la vapeur d’éluant avant la chromatographie.

Espagnol

Conserver la fiche 54

Fiche 55 1996-07-15

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
OBS

Chromatographie en phase gazeuse. Foxboro propose le modèle 931, un chromatographe à four chauffé par air pulsé qui comporte les caractéristiques suivantes : détecteurs(catharomètre ou ionisation de flamme) ;contrôleur d’automatisation à microprocesseur; possibilité d’un compteur numérique et d’une interface opératoire centrale.

Espagnol

Conserver la fiche 55

Fiche 56 1996-05-13

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
CONT

Si, dans son utilisation la plus classique, la chromatographie analytique est une méthode de laboratoire servant soit à la recherche, soit au contrôle courant des matières premières et des produits fabriqués par analyse de prélèvements extemporanément certaines formes de chromatographie, notamment en phase gazeuse, permettent une analyse automatique en ligne dans une fabrication, elle-même éventuellement en continu. Il faut noter que le processus chromatographique est essentiellement discontinu, mais qu'il peut être possible d’obtenir les séparations de façon suffisamment rapide pour qu'une répétitivité des analyses permette de suivre l'évolution d’un flux de matière. Le couplage des signaux de détection avec des calculateurs et des convertisseurs appropriés peut même permettre la régulation automatique des flux de réactifs pour ajuster une réaction donnée.

Espagnol

Conserver la fiche 56

Fiche 57 1996-05-13

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
DEF

Chromatographie en phase gazeuse. Possibilité de couplage direct. Couplage classique avec spectromètre de masse; également avec spectromètre infrarouge rapide. Liaison possible avec ordinateur.

Espagnol

Conserver la fiche 57

Fiche 58 1996-05-13

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
CONT

Chromatographie en phase gazeuse. Identification. Par grandeurs chromatographiques, détection spécifique, couplages, détermination de squelette.

Espagnol

Conserver la fiche 58

Fiche 59 1996-05-10

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
CONT

La chromatographie en phase gazeuse, récente, connaît un grand développement : le mélange à séparer, formé de liquides volatils, est vaporisé, dilué dans un gaz vecteur et envoyé dans une colonne contenant un liquide convenable immobilisé sur un support inerte; une séparation s’effectue par partage gaz-liquide, et bientôt le courant de gaz vecteur entraîne à la sortie de la colonne, les uns après les autres, les constituants du mélange.

Espagnol

Conserver la fiche 59

Fiche 60 1996-04-19

Anglais

Subject field(s)
  • Analytical Chemistry
DEF

A system for continuous, repetitive, and fully automatic online analysis of process streams similar in all essential element of the basic technique to the laboratory chromatograph, but different in design and appearance.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 60

Fiche 61 1996-03-25

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
CONT

Les pressions élevées en tête de colonne, pouvant atteindre 300 bar, interdisent l'utilisation d’une injection par seringue à travers un septum comme en chromatographie en phase gazeuse.

Espagnol

Conserver la fiche 61

Fiche 62 1996-02-15

Anglais

Subject field(s)
  • Analytical Chemistry
CONT

Bartz and Ruhl designed a rapid scanning infrared gas chromatography unit to utilize the chromatograph's ability to separate individual components in complex mixtures and the infrared's capabilities to identify the reasonably pure eluted fractions by their specific adsorption spectra.

Français

Domaine(s)
  • Chimie analytique

Espagnol

Conserver la fiche 62

Fiche 63 1995-12-28

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
CONT

La chromatographie en phase gazeuse a vu son intérêt développé par la mise au point des détecteurs à capture d’électrons, à microcoulométrie et à ionisation de flamme alcaline.

Espagnol

Conserver la fiche 63

Fiche 64 1994-07-04

Anglais

Subject field(s)
  • Analytical Chemistry
OBS

gas chromatography

Français

Domaine(s)
  • Chimie analytique
OBS

chromatographie en phase gazeuse

Espagnol

Conserver la fiche 64

Fiche 65 1994-07-04

Anglais

Subject field(s)
  • Analytical Chemistry
OBS

gas chromatography

Français

Domaine(s)
  • Chimie analytique
OBS

chromatographie en phase gazeuse

Espagnol

Conserver la fiche 65

Fiche 66 1994-07-04

Anglais

Subject field(s)
  • Analytical Chemistry
OBS

gas chromatography

Français

Domaine(s)
  • Chimie analytique
OBS

chromatographie en phase gazeuse

Espagnol

Conserver la fiche 66

Fiche 67 1991-01-03

Anglais

Subject field(s)
  • Analytical Chemistry
OBS

a type of gas chromatography

Français

Domaine(s)
  • Chimie analytique
OBS

type de chromatographie

Espagnol

Conserver la fiche 67

Fiche 68 1990-02-01

Anglais

Subject field(s)
  • Plastic Materials
DEF

a proprietary porous linear polymer resin packing for gas chromatography, composed of poly =0=2,6-diphenylphenylene oxide; it is stable to temperatures in excess of 400 C and is resistant to oxygen in the carrier gas.

Français

Domaine(s)
  • Matières plastiques
DEF

Produit de remplissage à base d’une résine linéaire poreuse, utilisée en chromatographie gazeuse; ce composé, qui est breveté, est de l'oxyde de poly-0-2, 6-diphénylphénylène; il est stable jusqu'à des températures dépassant 400 C et il résiste à l'oxygène dans le gaz vecteur.

Espagnol

Conserver la fiche 68

Fiche 69 1989-04-25

Anglais

Subject field(s)
  • Environmental Studies and Analyses
  • Analytical Chemistry
  • Scientific Measurements and Analyses

Français

Domaine(s)
  • Études et analyses environnementales
  • Chimie analytique
  • Mesures et analyse (Sciences)

Espagnol

Conserver la fiche 69

Fiche 70 1987-09-02

Anglais

Subject field(s)
  • Sugar Industry
OBS

The determination of sucrose in concentrated Steffen filtrate by G.L.C.

Français

Domaine(s)
  • Sucrerie (Industrie de l'alimentation)
CONT

Dosage, par chromatographie en phase gazeuse, du saccharose dans les filtrats concentrés du procédé Steffen.(Base Pascal)

Espagnol

Conserver la fiche 70

Fiche 71 1986-02-01

Anglais

Subject field(s)
  • Museums and Heritage

Français

Domaine(s)
  • Muséologie et patrimoine
OBS

Appareil d’Hewlett-Packard utilisé à l’ICC (Spectromètre)

Espagnol

Conserver la fiche 71

Fiche 72 1984-11-27

Anglais

Subject field(s)
  • Titles of Documents and Works
OBS

Trademark for a series of screened calcined and flux-calcined diatomite aggregates. Available in non-acid washed, acid-washed, and acid-washed dimethyldichlorosilane treatments.

Français

Domaine(s)
  • Titres de documents et d'œuvres
OBS

Nom déposé pour une famille d’agrégats de diatomées calcinées. Support pour chromatographie en phase gazeuse.

Espagnol

Conserver la fiche 72

Fiche 73 1976-06-19

Anglais

Subject field(s)
  • Analytical Chemistry

Français

Domaine(s)
  • Chimie analytique
OBS

Chromatographie en phase gazeuse.

Espagnol

Conserver la fiche 73

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :