TERMIUM Plus®

La banque de données terminologiques et linguistiques du gouvernement du Canada.

COURANT SONDE [11 fiches]

Fiche 1 2024-02-23

Anglais

Subject field(s)
  • Calorimetry
  • Lasers and Masers
DEF

... the measurement of laser-pulse energy by measuring the increase in temperature of an optical absorber irradiated by a laser beam.

Français

Domaine(s)
  • Calorimétrie
  • Masers et lasers
CONT

La calorimétrie laser est le moyen le plus courant et le plus ancien de mesurer les très faibles absorptions. Il consiste à mesurer directement l'élévation de température du composant optique grâce à un thermocouple ou une sonde de température [...]

Espagnol

Conserver la fiche 1

Fiche 2 2022-05-05

Anglais

Subject field(s)
  • Optics
  • Biophysics
  • Scientific Instruments
  • Atomic Physics
CONT

Scanning tunnelling microscopy (STM) has proved to be a ... powerful technique in the field of surface science. The fact that sets the STM apart from most other surface sensitive techniques is its ability to resolve the structure of surfaces on an atomic scale, that is atom-by-atom, and furthermore its ability to study the dynamics of surface processes.

OBS

Scanning tunneling microscopy - The development of the family of scanning probe microscopes started with the original invention of the STM in 1981.

Français

Domaine(s)
  • Optique
  • Biophysique
  • Instruments scientifiques
  • Physique atomique
DEF

Microscopie à sonde locale qui utilise la mesure de l'intensité du courant électrique dû au passage des électrons par effet tunnel entre la pointe de la sonde et la surface de l'échantillon.

CONT

La [...] microscopie à effet tunnel(STM) a été inventée par G. Binning et H. Rohrer en 1981. Son principe est le même que la microscopie optique à champ proche. Une sonde métallique est approchée au plus près de la surface d’un matériau conducteur, afin de détecter les ondes électroniques évanescentes des électrons de conduction du métal. On sait que l'amplitude de ces ondes décroît exponentiellement en fonction de la distance à la surface pour un observateur placé en dehors du métal. Le courant tunnel sonde-surface est donc une fonction décroissante de la distance qui sépare la surface de l'apex de la pointe : typiquement un ordre de grandeur par 0, 1 nm [nanomètre]. De plus, le courant tunnel reste très localisé au voisinage de la pointe. En balayant avec cette sonde la surface à analyser et en conservant le courant constant, le signal d’erreur de la boucle de contre-réaction permet de reconstruire une image de la surface avec une résolution latérale inférieure à 0, 2 nm, et une résolution verticale inférieure à 0, 05 nm.

OBS

La microscopie à effet tunnel nécessite que la pointe de la sonde et la surface de l’échantillon soient toutes deux conductrices.

OBS

microscopie à effet tunnel; MET : désignations et définition publiées au Journal officiel de la République française le 28 janvier 2020.

Espagnol

Campo(s) temático(s)
  • Óptica
  • Biofísica
  • Instrumentos científicos
  • Física atómica
CONT

El presente proyecto comprende el diseño e implementación de un sistema de microscopía de efecto túnel, este sistema se basa en la utilización de las propiedades de movimiento nanométrico de los materiales piezoeléctricos y de la capacidad de tunelaje de electrones a través de una barrera de potencial, para desarrollar un sistema de topografía nanométrica.

CONT

La invención de la microscopía de efecto túnel posibilitó el desarrollo de las llamadas microscopías de campo cercano [...]

Conserver la fiche 2

Fiche 3 2015-10-08

Anglais

Subject field(s)
  • Environmental Studies and Analyses
  • Scientific Measurements and Analyses
  • Hydrology and Hydrography
DEF

A technique in which the sample from a water stream passes into the orifice of a sampling probe with a velocity equal to that of the stream in the immediate vicinity of the probe.

OBS

isokinetic sampling: term and definition standardized by ISO.

Français

Domaine(s)
  • Études et analyses environnementales
  • Mesures et analyse (Sciences)
  • Hydrologie et hydrographie
DEF

Technique consistant à faire passer l'échantillon d’un courant d’eau dans l'orifice d’une sonde d’échantillonnage avec une vitesse égale à celle du courant à proximité immédiate de la sonde.

OBS

échantillonnage isocinétique : terme et définition normalisés par l’ISO.

Espagnol

Campo(s) temático(s)
  • Estudios y análisis del medio ambiente
  • Medición y análisis (Ciencias)
  • Hidrología e hidrografía
DEF

Técnica en la que la muestra de una corriente de agua pasa por el orificio de una sonda de muestreo, con una velocidad igual a la de la corriente en la proximidad inmediata de la sonda.

Conserver la fiche 3

Fiche 4 2014-05-21

Anglais

Subject field(s)
  • Biochemistry
CONT

Methods for isolation and purification of beta-galactosidase from Bacillus subtilis, st. IBP-101 are described. The bacterial cells were disrupted by different procedures such as freezing and thawing with subsequent autolysis at 37 degrees C, disrupting in a French press DKM-3 or in ultrasonic desintegrators UZDN-1 (USSR) and Soniprep-150. It is shown that the specific activity and yield of the enzyme depends to a great extent on the disrupting procedure used.

OBS

Excerpted from the BIOSIS data base.

Français

Domaine(s)
  • Biochimie
DEF

Appareil utilisant l’énergie des ultrasons pour réaliser diverses opérations : désintégration, dispersion, homogénéisation, émulsion, etc.

CONT

Le sonicateur est utilisé, en chimie et en physique, pour désagréger un solide en suspension dans un liquide, disperser un liquide dans un autre, dépolymériser de grosses molécules et, en biologie, pour casser les membranes de cellules afin d’en extraire les constituants. L'énergie ultrasonore est transmise au milieu par une sonde mise en vibration par un cristal piézo-électrique excité par un courant haute fréquence.

Espagnol

Campo(s) temático(s)
  • Bioquímica
CONT

El sonicador tiene dos formas de operar, por pulsos: las vibraciones de ultrasonido pueden transmitirse en una solución en un rango de 0,1 a 0,9 pulsos por segundo, permitiendo una adecuada sonicación sin generación importante de calor, y continuo: puede ser usado de forma continua por hasta 15 minutos. Con este sistema se puede lograr la ruptura de levaduras entre 3 y 10 minutos o de E.Coli con 40 segundos.

Conserver la fiche 4

Fiche 5 2012-01-16

Anglais

Subject field(s)
  • Equipment (Chemistry)
DEF

An instrument for producing high-intensity ultrasound, consisting of a converter that transforms electrical energy into mechanical energy in the form of oscillation of piezoelectric transducers at a frequency of 20 kilohertz, and a titanium horn that focuses this oscillation and radiates energy into the liquid being treated through a tip.

CONT

Sonication is the act of applying sound (usually ultrasound) energy to agitate particles in a sample, for various purposes. In the laboratory, it is usually applied using an ultrasonic bath or an ultrasonic probe, colloquially known as a sonicator. ... Sonication can be used to speed dissolution, by breaking intermolecular interactions. ... In biological applications, sonication may be sufficient to disrupt or deactivate a biological material. ... Sonication is commonly used in nanotechnology for evenly dispersing nanoparticles in liquids. Sonication can also be used to initiate crystallisation processes and even control polymorphic crystallisations. ... Sonication is the mechanism used in ultrasonic cleaning; loosening particles adhering to surfaces. Outside the field of laboratory science, sonicating baths are used to clean objects such as spectacles and jewelry. Sonication is also used to extract microfossils from rock.

OBS

[Sonicator is also a trademark of] Qsonica. The Sonicator brand was originally produced by Heat Systems Ultrasonics in the 1970's. Heat Systems was re-named Misonix, Inc. in 1990. The Misonix Sonicator brand is now owned by Qsonica.

Français

Domaine(s)
  • Équipement (Chimie)
DEF

Appareil utilisant l’énergie des ultrasons pour réaliser diverses opérations : désintégration, dispersion, homogénéisation, émulsion, etc.

CONT

Le sonicateur est utilisé, en chimie et en physique, pour désagréger un solide en suspension dans un liquide, disperser un liquide dans un autre, dépolymériser de grosses molécules et, en biologie, pour casser les membranes de cellules afin d’en extraire les constituants. L'énergie ultrasonore est transmise au milieu par une sonde mise en vibration par un cristal piézo-électrique excité par un courant haute fréquence.

CONT

Sonde ultrasonore. Le second système consiste à immerger l’émetteur dans la solution à traiter. On désigne souvent le système, soit sous le nom de sonde à ultrasons (sonotrode) lorsqu’il est immergé par-dessus (figure 16a), soit de cup-horn lorsqu’il est immergé par-dessous (figure 16b).

CONT

Le second appareillage est la sonde à ultrasons. À la différence du bac, elle permet une irradiation directe du milieu tout en générant des puissances acoustiques nettement supérieures (plus de 100 fois plus élevées). Cependant, son utilisation reste seulement adaptée au traitement de petits volumes de liquide et une attention particulière doit être portée à ce type de manipulation car l’échantillon peut subir une augmentation rapide de température.

Espagnol

Conserver la fiche 5

Fiche 6 2011-05-27

Anglais

Subject field(s)
  • Telecommunications Transmission
  • Vacuum Tubes (Electronics)
DEF

In gas-filled tubes, the current flowing to or from an electrode when it does not form part of the main gap.

Français

Domaine(s)
  • Transmission (Télécommunications)
  • Tubes et lampes (Électronique)
DEF

Dans un tube à gaz, courant passant dans une électrode qui ne fait pas partie de l’espace principal de décharge.

Espagnol

Campo(s) temático(s)
  • Transmisión (Telecomunicaciones)
  • Tubos de vacío (Electrónica)
Conserver la fiche 6

Fiche 7 2005-09-13

Anglais

Subject field(s)
  • Medical Instruments and Devices
DEF

A catheter having two channels; one for injection and one for removal of fluid.

Terme(s)-clé(s)
  • double current catheter
  • two way catheter

Français

Domaine(s)
  • Instruments et appareillages médicaux
CONT

Enfin en cas de caillotage intravésicale une sonde à double courant est indispensable : un conduit permet l'injection continue du liquide de lavage, l'autre permet le recueil.

Espagnol

Conserver la fiche 7

Fiche 8 2000-06-27

Anglais

Subject field(s)
  • Flight Controls (Aeroindustry)
OBS

eddy current probe: term officially approved by the International Civil Aviation Organization (ICAO).

Français

Domaine(s)
  • Commandes de vol (Constructions aéronautiques)
OBS

sonde à courant de Foucault : terme uniformisé par l'Organisation de l'aviation civile internationale(OACI).

Espagnol

Campo(s) temático(s)
  • Mandos de vuelo (Industria aeronáutica)
OBS

detector por corriente de Foucault : término aceptado oficialmente por la Organización de Aviación Civil Internacional (OACI).

Conserver la fiche 8

Fiche 9 1992-10-28

Anglais

Subject field(s)
  • Printed Circuits and Microelectronics

Français

Domaine(s)
  • Circuits imprimés et micro-électronique
DEF

Détermination de la résistivité superficielle des circuits intégrés au moyen d’une sonde à quatre aiguilles de mesure venant s’appliquer sur la puce. On fait passer un courant constant entre les pointes extrêmes pour ensuite mesurer la différence de potentiel entre les deux pointes centrales. La tension ainsi obtenue permet de déduire la valeur de la résistivité superficielle du circuit.

Espagnol

Conserver la fiche 9

Fiche 10 1982-03-09

Anglais

Subject field(s)
  • Conductors and Resistors
OBS

The current flow is proportional to the concentration of oxygen. As the results obtained can vary with temperature, the probe has a built-in compensating thermistor.

Français

Domaine(s)
  • Conducteurs et résistances
OBS

L'intensité du courant débité est proportionnelle à la concentration en oxygène. Les résultats donnés pouvant varier avec la température, la sonde comporte une thermistance de compensation incorporée.

Espagnol

Conserver la fiche 10

Fiche 11 1976-06-19

Anglais

Subject field(s)
  • Electronics

Français

Domaine(s)
  • Électronique

Espagnol

Conserver la fiche 11

Avis de droit d’auteur pour la banque de données TERMIUM Plus®

© Services publics et Approvisionnement Canada, 2025
TERMIUM Plus®, la banque de données terminologiques et linguistiques du gouvernement du Canada
Un produit du Bureau de la traduction

En vedette

Portail linguistique du Canada

Accédez à une collection de ressources canadiennes sur tous les aspects du français et de l'anglais, y compris des jeux.

Outils d'aide à la rédaction

Les outils d’aide à la rédaction du Portail linguistique ont fait peau neuve! Faciles à consulter, ils vous donnent accès à une foule de renseignements utiles pour mieux écrire en français et en anglais.

Lexiques et vocabulaires

Accédez aux lexiques et vocabulaires du Bureau de la traduction.

Date de modification :