AIR DAMPER [35 records]

Record 1 2019-07-10

English

Subject field(s)
  • Air Conditioning and Heating
CONT

The mixing damper controls flow from the left inlet branch as a percentage of the mixed-air flow, subject to a preset minimum. The minimum can be scheduled or modulated by a time-switch profile in the damper component dialog. A controller then modulates flow from the left branch vs. bottom branch as a percentage of the outlet flow rate or in an attempt to achieve a target mixed-air temperature. Typical applications include outside air economizers, demand-controlled ventilation, and bypass dampers for heat-recovery, indirect evaporative cooling, heat pipes, coils with high static pressure, or similar components within an air handler.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 1

Record 2 2019-07-04

English

Subject field(s)
  • Chimneys (Building Elements)
  • Heating
DEF

A pivoted metal plate, set just above the throat in a chimney, that controls the draft ... through a fireplace and up the chimney; may be used to close off the chimney when the fireplace is not in use.

CONT

If you have ever opened the fireplace damper before lighting a fireplace and felt a big flow of cold air come into the room, you have encountered a backdraft.

Key term(s)
  • fire place damper

French

Domaine(s)
  • Cheminées (Éléments du bâtiment)
  • Chauffage
CONT

Si vous avez déjà ouvert le registre du foyer avant d'y allumer un feu et senti un fort courant d'air froid qui entre dans la pièce, il s'agissait alors d'un refoulement.

Spanish

Save record 2

Record 3 2018-02-12

English

Subject field(s)
  • Mechanical Components
  • Air Conditioning and Heating
CONT

... Air Handling Units.... Clean damper operators.

French

Domaine(s)
  • Composants mécaniques
  • Conditionnement de l'air et chauffage

Spanish

Save record 3

Record 4 2018-01-04

English

Subject field(s)
  • Air Conditioning and Heating
CONT

Alternatively, the supply air may not be HEPA [high efficiency particulate air] filtered but equipped with a fast-acting bioseal damper which is interlocked with the exhaust fan to ensure that potentially contaminated air is not released through the air intake during an HVAC [heating, ventilation and air-conditioning] failure.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 4

Record 5 2011-05-03

English

Subject field(s)
  • Air Conditioning and Heating
OBS

outside air damper : term officially approved by the Lexicon Project Committee(New Brunswick).

French

Domaine(s)
  • Conditionnement de l'air et chauffage
OBS

registre d'air extérieur : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 5

Record 6 2011-02-22

English

Subject field(s)
  • Mechanical Components
  • Air Conditioning and Heating
DEF

A damper fitted across the face area of an air cooling coil or other equipment in order to control quantity of air flowing through it.

OBS

face damper: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Composants mécaniques
  • Conditionnement de l'air et chauffage
OBS

registre de surface frontale : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 6

Record 7 2008-02-19

English

Subject field(s)
  • Energy Transformation
  • Solar Energy
DEF

[A situation that occurs] when heat seeks to flow from a warm area(e. g., heated space) to a cooler area, such as a solar air collector at night without a reverse flow damper.

French

Domaine(s)
  • Transformation de l'énergie
  • Énergie solaire
DEF

Situation se produisant lorsque la chaleur tend à passer d'une zone chaude, par exemple un espace chauffé, à une zone froide, comme peut le faire durant la nuit un capteur solaire à air dépourvu de régulateur d'écoulement inversé.

Spanish

Save record 7

Record 8 2006-04-21

English

Subject field(s)
  • Security Devices
  • HVAC Distribution Systems
  • Fire Safety
DEF

... a closure which consists of a normally held open damper installed in an air distribution system or in a wall or floor assembly, and designed to close automatically in the event of a fire in order to maintain the integrity of the fire separation.

French

Domaine(s)
  • Dispositifs de sécurité
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Sécurité incendie
DEF

Dispositif d'obturation consistant en un registre normalement maintenu ouvert, placé soit dans un réseau de distribution d'air, soit dans un mur ou un plancher et conçu pour se fermer automatiquement en cas d'incendie afin d'assurer l'intégrité de la séparation coupe-feu.

OBS

registre coupe-feu : terme uniformisé par le Groupe de travail de terminologie du génie.

Spanish

Campo(s) temático(s)
  • Dispositivos de seguridad
  • Sist. de calefacción, ventilación y acondicionamiento de aire
  • Seguridad contra incendios
Save record 8

Record 9 2003-03-26

English

Subject field(s)
  • Space Centres
CONT

The 1. 4-million pound mobile launching platform is what the Atlas 5 sits upon from the time it is stacked together in the VIF [Vertical Integration Facility] until the main engine is fired at liftoff.... The platform is 45 feet wide, 55 feet long and 185 feet tall to the top of the mast, which features a wind damper that holds the rocket steady while exposed to the weather on the pad and routes propellant lines to the Centaur and conditioned air to the payload inside the nose cone.

French

Domaine(s)
  • Centres spatiaux

Spanish

Save record 9

Record 10 2000-06-30

English

Subject field(s)
  • Burners and Steamfitting
DEF

A system in which the combustion rate of the burner can be set at either of 2 fixed levels.

CONT

The RL 10-20-30 BLU series burners are available in three model structures with an output range from 73/124 kW to 356 kW. Twin nozzle two stage firing operation as standard, the combustion air is controlled by a three position hydraulic ram which allows the air damper to fully close when the burner is at rest.

CONT

All models come with electric intermittent ignition pilot, adjustable high limit, 24 volt gas valve with either single-stage or two-stage firing. A motorized gas valve for modulation firing is also available.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Les brûleurs monoétagés fonctionnent en «tout ou rien», c'est-à-dire toujours à pleine puissance. Pour améliorer le rendement et faciliter la régulation, on utilise dans le cas de chaudières dont la puissance dépasse 100 kW, des brûleurs à deux étages à un ou deux gicleurs. De tels brûleurs fonctionnent en régulation flottante, à savoir : arrêt - charge partielle - pleine charge [...] À chaque allure correspond un thermostat ou un régulateur de pression.

OBS

[...] brûleurs à 2 allures.

Spanish

Save record 10

Record 11 2000-05-31

English

Subject field(s)
  • Burners and Steamfitting
  • Safety Devices (Mechanical Components)
  • Applications of Automation
  • Electrical Components
DEF

A flame safeguard control which recycles following a shutdown; it will restart the burner if conditions causing the shutdown have been corrected.

DEF

A primary safety control for automatically lighted burners which, upon accidental flame failure during a normal firing cycle and the subsequent shutoff of main burner fuel, will provide, after a pre-establishing shutdown period and under a normal starting program, one attempt to automatically light the main burner.

OBS

The interlock may be a combustion air controller..., a damper position indicator..., or a fuel pressure switch. It can be a recycling type, or it may require manual reset.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Organes de sécurité (Composants mécaniques)
  • Automatisation et applications
  • Composants électrotechniques

Spanish

Save record 11

Record 12 2000-04-28

English

Subject field(s)
  • Electrical Components
  • Control Instrumentation (Mechanical Components)
  • Safety Devices (Mechanical Components)
DEF

An interlock which proves a condition is proper for burner operation to continue through prepurge, ignition trials, and the run period. It is used with a primary or programming control which will shut down the burner if an improper conditions occurs. The interlock may be a combustion air controller(airflow switch), a damper position indicator(low or high fire proving switch), or a fuel pressure switch. It can be a recycling type, or it may require manual reset.

French

Domaine(s)
  • Composants électrotechniques
  • Dispositifs de commande (Composants mécaniques)
  • Organes de sécurité (Composants mécaniques)

Spanish

Save record 12

Record 13 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
  • Safety Devices (Mechanical Components)
  • Electrical Components
DEF

A flame safeguard control which does not recycle after shutdown.

DEF

A primary safety control which, upon accidental flame failure during a normal firing cycle, causes a safety shutdown.

OBS

The interlock may be a combustion air controller..., a damper position indicator..., or a fuel pressure switch. It can be a recycling type, or it may require manual reset.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Organes de sécurité (Composants mécaniques)
  • Composants électrotechniques
OBS

Le Sens-A-Flame est un système électronique de surveillance de flamme. Il détecte les défauts de flamme, enclenche une alarme et coupe l'alimentation en combustible. Il est disponible pour le contrôle de brûleurs séparés ainsi que de brûleurs multiples. Il comprend de nombreuses possibilités, sa technologie est complètement électronique, ses composants sont embrochables de façon à faciliter la maintenance. Il peut être utilisé avec électrode de flamme ou cellule U.V.

OBS

Flame Safeguard Control. Fireye: Régulateur automatique air/combustible, surveillance de flamme, télégestion de brûleur.

Spanish

Save record 13

Record 14 2000-04-28

English

Subject field(s)
  • Safety Devices (Mechanical Components)
  • Burners and Steamfitting
  • Applications of Automation
  • Electrical Components
DEF

A running interlock used with a primary or programming control which will shut down the burner if an improper condition occurs. The control will recycle; it will restart the burner if the condition corrects itself. The interlock is usually a combustion air controller (airflow switch).

OBS

The interlock may be a combustion air controller..., a damper position indicator..., or a fuel pressure switch. It can be a recycling type, or it may require manual reset.

French

Domaine(s)
  • Organes de sécurité (Composants mécaniques)
  • Fumisterie et brûleurs
  • Automatisation et applications
  • Composants électrotechniques

Spanish

Save record 14

Record 15 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
DEF

A prepurge period during which the air damper is driven open for the purge period and then back to low fire position for the burner lightoff.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Prébalage : [...] temps pendant lequel, pour les brûleurs de plus de 30 kg/h, le foyer est ventilé mécaniquement, sans appel de fuel; [...]

OBS

Brûleurs à fuel [...] La plupart des installations fonctionnent par intermittence en régulation «tout ou rien», par conséquent avec brûleur à pleine marche ou à l'arrêt. Dans certaines grosses installations, on prévoit plusieurs allures.

OBS

prébalayage / pre-purge.

Spanish

Save record 15

Record 16 2000-04-28

English

Subject field(s)
  • Combustion and Fuels (Fireplaces)
  • Burners and Steamfitting
CONT

open damper purge. During prepurge, the damper opens to high fire position and the burner motor drives air through the combustion chamber to remove any potentially explosive fuel or fumes. The damper closes to low fire position for ignition trials, and opens again to high fire position for the run period. Flame safeguard controls providing this feature have only 1 terminal for firing rate switching; they do not provide modulation during the run period.

French

Domaine(s)
  • Combustion et combustibles (Foyers)
  • Fumisterie et brûleurs

Spanish

Save record 16

Record 17 2000-04-28

English

Subject field(s)
  • Applications of Automation
  • Burners and Steamfitting
  • Electrical Components
DEF

The process of going through another operating cycle. For a flame safeguard control, automatically going through another timer cycle after a shutdown in an attempt to restart the burner.

OBS

The interlock may be a combustion air controller..., a damper position indicator..., or a fuel pressure switch. It can be a recycling type, or it may require manual reset.

French

Domaine(s)
  • Automatisation et applications
  • Fumisterie et brûleurs
  • Composants électrotechniques

Spanish

Save record 17

Record 18 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
CONT

Low-high-low prepurge-a prepurge period during which the air damper is driven open for the purge period and then back to low fire position for the burner lightoff. This is called low-high-low proven prepurge if suitable interlocks indicate that the damper actually reached the open position during prepurge, and then closed again before ignition trials.

OBS

See records "low-high-low prepurge", "proved ignition" and "proven prepurge".

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Voir les fiches «prébalayage allures minimale-maximale-minimale», «allumage par étincelle contrôlée» et «prébalayage contrôlé».

Spanish

Save record 18

Record 19 2000-02-29

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Cooling and Ventilating Systems
  • HVAC Distribution Systems
DEF

A damper, circular in shape, with a contractible diaphragm consisting of pivoted shutters which can vary the aperture size.

CONT

... a single devise permits airflow to be adjusted and measured at one location, resulting in reduced field time and improved accuracy in air balancing. The new Iris Damper uses interlocking steel plates and a calibrated control lever to form an adjustable aperture.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Systèmes de refroidissement et de ventilation
  • Distribution et évacuation (chauffage et conditionnement d'air)
DEF

Registre constitué, dans un cadre circulaire, par un ensemble de petits volets dont le pivotement conjugué laisse au centre un passage de section variable.

CONT

On distingue par exemple les types [de registres] suivants : [...] - registres du type iris, comportant des volets en forme de secteur [...]

Spanish

Save record 19

Record 20 1999-11-30

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • HVAC Distribution Systems
DEF

A valve or plate regulating the flow of air or other fluid.

CONT

The damper is usually a sheet metal disc that can be turned inside the round supply duct to adjust the flow of air...

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Distribution et évacuation (chauffage et conditionnement d'air)
DEF

Organe placé dans un conduit aéraulique, dans un conduit de fumée, ou, d'une manière générale, dans tout conduit, pour régler le débit de fluide en faisant pivoter une ou plusieurs lames autour d'un ou de plusieurs axes.

CONT

Un registre se présente le plus souvent sous forme d'un (ou deux) volet(s) d'air servant à régler le débit de cet air dans une canalisation ou gaine de soufflage. Il peut également faire partie d'une grille ou bouche de soufflage (grille à registre, c'est-à-dire munie de volets de réglage).

Spanish

Save record 20

Record 21 1999-11-23

English

Subject field(s)
  • Rail Transport
CONT

In addition to its main and obvious function the ashpan is provided to regulate, through damper doors, the amount of air entering the grate.

CONT

The ashpan is made of plate iron 1/4 inch in thickness, framed with angle iron, having a band of flat iron at the top.

French

Domaine(s)
  • Transport par rail
DEF

Espace libre, situé au-dessous du foyer d'une locomotive, où tombent les escarbilles, les cendres.

Spanish

Save record 21

Record 22 1999-10-28

English

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
DEF

A furnace equipped with a fan that provides the primary means for the circulation of air.

CONT

Warm air furnaces are of two types, gravity and forced air. Forced warm air furnaces use a motor-driven blower to circulate air over the heat exchanger and through the ducts. A draft hood is attached to the outlet of the furnace and replaces the barometric damper.

OBS

Forced-warm-air furnaces are most commonly fired by LP gas, natural gas or oil and occasionally by wood and coal. They may also operate electrically.

French

Domaine(s)
  • Fours et chaudières (Chauffage)
DEF

Générateur d'air chaud doté d'un ventilateur qui constitue le moyen principal de circulation de l'air.

CONT

Générateurs d'air pulsé. (...) ces générateurs sont constitués des éléments suivants : -un caisson d'aspiration (...) -un ventilateur centrifuge (...) -un corps de chauffe (...) -un bloc de distribution à plusieurs bouches; -une sortie de fumée avec modérateur de tirage. L'ensemble est enfermé dans un habillage calorifugé en acier laqué; il est complété par un organe de régulation qui commande la marche du ventilateur en fonction de la température de l'air.

OBS

Dans le système de chauffage à air pulsé, la circulation d'air est assurée par un ventilateur électrique (...) Ce système permet de placer la fournaise n'importe où et d'utiliser des conduits plus étroits et plus longs.

OBS

Fournaise : Ce terme est considéré comme impropre par les puristes. Selon Dagenais, dans son "Dictionnaire des difficultés de la langue française au Canada", "fournaise" serait un calque de l'anglais "furnace" et nous devrions plutôt dire "chaudière" lorsque le fluide caloporteur est l'eau ou la vapeur et "générateur d'air chaud", lorsque le fluide, est l'air. Cependant, ce terme reste d'usage fréquent au Québec, autant en langue parlée qu'en langue écrite.

Spanish

Save record 22

Record 23 1990-12-30

English

Subject field(s)
  • HVAC Distribution Systems
DEF

Multiblade damper to prevent outside air from passing through the unit in reverse direction when the fan is not operating.

Key term(s)
  • back draft damper
  • backdraft shutter

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Clapet de retenue ou clapet antiretour: accessoire de tuyauterie destiné à empêcher le retour en arrière du produit qui y circule [...]

Spanish

Save record 23

Record 24 1990-10-02

English

Subject field(s)
  • Burners and Steamfitting
CONT

The high pressure atomizing type gun... burner supplies oil to the atomizing nozzle at 689 to 2067 kPa. A blower is used to supply the air for combustion, and a damper or other adjustable means regulates the air supply at the burner. Ignition is usually established by a high voltage electric spark which may be intermittent, sometimes called constant ignition(on when the burner motor is on) or interrupted(on only to start combustion). Typically these burners fire into a combustion chamber in which negative draft is maintained.

French

Domaine(s)
  • Fumisterie et brûleurs

Spanish

Save record 24

Record 25 1990-04-11

English

Subject field(s)
  • HVAC Distribution Systems
OBS

Inlet air is proportioned through the heating and bypass channels by V shaped "Air-Flow-Line" dampers, positioned by a damper motor. The patented "Air-Flow-Line" dampers guide a smooth flow of air through the section to reduce air static losses. These dampers maintain a constant pressure drop and, therefore, a constant air volume through the heating coil is maintained regardless of damper position.(from an advertising leaflet of WING who manufactured the IFB [Integral face-and-bypass] heating coil).

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Il s'agit d'un appareil qui décide de la quantité d'air qui doit passer par une prise d'air pour climatisateur d'immeuble en fonction de la température de l'air à l'extérieur. Si l'air doit être chauffé, il entre directement vers l'unité de chauffage; s'il est déjà chaud, des conduites de dérive lui font éviter l'unité de chauffage.

OBS

La proposition est utilisée à la section technique à Montréal.

Spanish

Save record 25

Record 26 1990-01-08

English

Subject field(s)
  • HVAC Distribution Systems
OBS

An outdoor-air intake can be provided in a forced-air system, for introducing outdoor ventilation air into the structure.... This outdoor air should be conveyed through an individual duct leading from the outdoors directly to the return plenum of the furnace and should be provided with a manually-operated damper.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
CONT

[Chauffage à air chaud.] Gaines de prise d'air neuf (...) Dans le but de renouveler l'air des locaux, on peut reprendre de l'air à l'extérieur soit en partie, soit en totalité. Le raccord à la chaudière se fait à l'aide d'un té. Une des branches apporte l'air neuf, l'autre l'air de reprise. Un registre permet de régler la proportion d'air frais par rapport à l'air de reprise. Ce système provoque une dépense supplémentaire en combustible. En effet, il faut élever la température de l'air venant de l'extérieur à la température de soufflage.

OBS

En chauffage, la préférence semble aller au terme "gaine" plutôt qu'au terme "conduit". Cependant l'Ordre des architectes du Québec en déconseille l'emploi dans l'usage canadien.

Spanish

Save record 26

Record 27 1990-01-08

English

Subject field(s)
  • HVAC Distribution Systems
CONT

Warm Air Registers ... can be installed in the floor, the baseboard, above the baseboard, high in the side wall, in the ceiling, in the window ledge, or in any other place to which a duct can be run.... In general (a) the register should introduce the air into the room in such a manner that the air does not strike an occupant that is seated and at rest, (b) it should tend to overcome the downdrafts that occur below windows and cold walls, (c) it should not interfere with furniture placement.

OBS

air register : Combination grille and damper used on the end of a duct system to direct the airflow into a room.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

grille à registre : Ensemble apparié d'une grille et d'un registre.

Spanish

Save record 27

Record 28 1988-09-15

English

Subject field(s)
  • Gas and Oil Heating
CONT

Burner Efficiency Tests and Adjustments. For burner adjustment the serviceman measures the draft that provides air for combustion and the smoker or soot content of the exiting flue gases.... Measurements are made through a small hole in the flue pipe within 46 cm of the flue gas exit on the furnace. If the layout of the flue pipe makes this impossible, the serviceman has to make a hole wherever he can.... It should be located between the furnace and the barometric damper but not directly beside the barometric damper.

French

Domaine(s)
  • Chauffage au gaz et au mazout

Spanish

Save record 28

Record 29 1986-12-05

English

Subject field(s)
  • HVAC Distribution Systems
  • Building Ventilation
CONT

It is advisable, where physically possible, to size the fresh-air duct for the full capacity of the air-handling unit.... A damper in the fresh-air duct will throttle the air to 1000 ft 3/min during the cooling season;....

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Ventilation (Construction)
CONT

(...) schéma d'une installation climatique où l'on remarque: (...) la gaine (ou conduit) d'air neuf, communiquant avec l'extérieur par une prise d'air neuf; (...)

Spanish

Save record 29

Record 30 1986-09-25

English

Subject field(s)
  • Wastewater Treatment
  • Air Pollution
CONT

Baghouse Types. Baghouses are generally referred to by their construction as either compartmented or uncompartmented. The compartmented bag collector(Figure 12) is used with either reverse air flow or shaker type bag cleaning. This type of collector is divided into several compartments, each with its own damper and bag cleaning system. One compartment at a time can be taken out of service to release the dust from the bags into the bottom hopper.

French

Domaine(s)
  • Traitement des eaux usées
  • Pollution de l'air

Spanish

Save record 30

Record 31 1986-04-01

English

Subject field(s)
  • Fueling Systems (Motor Vehicles)
CONT

The diaphragm [of the air cleaner with a thermostatic control] is pushed upward by atmospheric pressure and the diaphragm spring is compressed. In this position, the linkage from the diaphragm raises the damper valve.

French

Domaine(s)
  • Alimentation (Véhicules automobiles)

Spanish

Save record 31

Record 32 1986-04-01

English

Subject field(s)
  • Fueling Systems (Motor Vehicles)
CONT

A vacuum override motor is connected to the flap inside the snorkel of some thermostatically controlled damper flap units. When a cold engine is accelerating, the vacuum diaphragm overrides the thermostat control to open the damper flap. This allows outside air as well as heated air to enter the system.

French

Domaine(s)
  • Alimentation (Véhicules automobiles)

Spanish

Save record 32

Record 33 1985-10-30

English

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Forced Air Wood Furnaces. Central wood-burning furnaces are controlled by a wall mounted thermostat in the living area. Temperature and fan controls are the same as those found on oil and gas furnaces. Unlike room heaters, which produce a steady heat output by periodic manual adjustments of the draft control, most wood furnaces operate in cycles. A cycle starts with the thermostat sensing that heat is needed in the room where it is located. It signals the furnace control system which opens the combustion air damper and a hot fire develops. When the air inside the furnace's sheet metal casing gets hot, a preset fan control starts the circulating blower and the warm air is moved through the ducts to all areas of the house.

French

Domaine(s)
  • Fours et chaudières (Chauffage)

Spanish

Save record 33

Record 34 1985-10-23

English

Subject field(s)
  • Gas and Oil Heating
  • Ovens, Furnaces and Boilers (Heating)
CONT

With conventional gas furnaces, little can be done to prevent losses of heated house air up the chimney when the furnace is firing. What can be prevented, though, is the loss that occurs when the furnace is not firing. A positive vent damper consists of a tight-fitting hinged damper door mounted in a steel collar and fitted into the flue pipe just before the pipe enters the chimney base. A fail-safe interlock switch prevents the furnace from firing unless the damper is completely open. This device may also be used with propane furnace.

French

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fours et chaudières (Chauffage)

Spanish

Save record 34

Record 35 1982-08-10

English

Subject field(s)
  • HVAC Distribution Systems
OBS

Outdoor air intake openings into the cold air return system shall be provided with a manually operated or automatic damper.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Les prises d'air extérieures d'un circuit de reprise d'air froid doivent être munies d'un registre manuel ou automatique.

Spanish

Save record 35

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: