TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

AIR VALVE COMPARTMENT [9 records]

Record 1 2016-07-29

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Taps and Plumbing Accessories
  • Cooking Appliances
CONT

After closing and sealing the door, setting the timer, and pulling out the operating handle, the steam inlet valve from the boiler opens, allowing steam at a pressure of 6 psi to enter the compartment. Air from the sealed compartment exits through the vent until the temperature reaches 180°F; then the vent closes and the compartment can become pressurized.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Robinetterie et accessoires
  • Appareils de cuisson des aliments
CONT

Une fois le temps de cuisson écoulé, interrompre l'admission de vapeur progressivement en ramenant lentement la manette en position première; ceci a pour effet de fermer le robinet d'admission de vapeur et d'ouvrir le robinet de purge ou de vidange.

Spanish

Save record 1

Record 2 2004-05-14

English

Subject field(s)
  • Aircraft Propulsion Systems
CONT

General Electric-$290 million to supply pneumatic products for the GE-Pratt & Whitney Engine Alliance GP7200 engines for the Airbus A380. The package also consists of an Air Turbine Starter and six pneumatic system valves that include an air turbine start valve, high and low pressure turbine clearance control valves, a start transient bleed valve, the core compartment cooling valve and an anti-ice valve for the nacelle.

French

Domaine(s)
  • Propulsion des aéronefs
CONT

soupapes pour systèmes hydrauliques d'avions - soupapes pour systèmes pneumatiques d'avions.

OBS

Systèmes Pneumatiques et Hydrauliques. [...] Auxiliaires pneumatiques : temporisateurs, réducteurs de débit, soupapes d'échappement rapide, connectique.

OBS

Composants pneumatiques. Composants et systèmes fluidiques. Détendeurs. Embrayages pneumatiques. Fonctions logiques. Freins à commande pneumatique. Limiteurs de débit. Limiteurs de pression. Régulateurs de débit. Sélecteurs de circuit. Soupapes de sûreté. Soupapes d'étranglement.

Spanish

Save record 2

Record 3 2003-05-21

English

Subject field(s)
  • Control Instrumentation (Mechanical Components)
OBS

the flight station duct rate sensor is located in the APU compartment in the right air conditioning discharge duct between the temperature control valve C and the water separator.

French

Domaine(s)
  • Dispositifs de commande (Composants mécaniques)
OBS

[Le] système [de régulation de température] se compose des accessoires suivants: - Échangeur air-air [...] - Vanne de régulation [...] - Sonde de régulation [...]

Spanish

Campo(s) temático(s)
  • Dispositivos de mando (Componentes mecánicos)
Save record 3

Record 4 1987-05-04

English

Subject field(s)
  • Aeroindustry
CONT

The [freeze prevention] system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air. The system taps into the APU bleed air supply duct before the check valve at the elbow under the catwalk and air is distributed by auxiliary ducts to a muffler under the flow control valve of each pack and to a single spray bar upstream of the left diverter valve. A temperature control valve in the ducting regulates the volume of bleed air to be used.

French

Domaine(s)
  • Constructions aéronautiques
CONT

Ce silencieux est fixé par vis sur la prise d'air du refroidisseur d'huile. Il est constitué d'une cuvette et d'un couvercle percés de plusieurs orifices qui permettent le passage de l'air de refroidissement. L'insonorisation est assurée par de la laine de verre qui est placée à l'intérieur de la cuvette.

OBS

silencieux : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 4

Record 5 1987-02-10

English

Subject field(s)
  • Aircraft Systems
CONT

The freeze prevention system maintains the air-conditioning system in a freeze free operating condition in cold weather with extremely high humidity on the ground. The system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air.

OBS

in water separator.

French

Domaine(s)
  • Circuits des aéronefs
OBS

système antigivrage : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 5

Record 6 1987-02-02

English

Subject field(s)
  • Aircraft Systems
CONT

The rudder hydraulic power shutoff system controls the supply of hydraulic pressure to the rudder hydraulic power package. The system is mechanically controlled by a lever in the flight compartment. The shutoff system consists of a hydraulic shutoff valve, located in the aft accessory compartment below the right air conditioning unit, connected by a two-way cable system to a control lever on the control pedestal. The shutoff valve is connected, by hydraulic lines, to the right hydraulic power system and the hydraulic power package.

French

Domaine(s)
  • Circuits des aéronefs
OBS

circuit d'arrêt hydraulique gouverne de direction : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 6

Record 7 1986-10-08

English

Subject field(s)
  • Aircraft Systems
CONT

Ventilating air for cooling the generator, the oil cooler, and the APU compartment is obtained from the aft accessory compartment and is ducted through a fire isolation valve into the APU enclosure.... The remainder of the ventilating air is ducted into the APU-driven cooling fan which forces the air through the APU oil cooler into the general compartment. Some of the fan air is diverted from the oil cooler into a distribution duct which directs cooling air to the APU enclosure. The compartment is vented through a sound suppressing muffler and thence overboard by an air discharge duct.

French

Domaine(s)
  • Circuits des aéronefs
OBS

gaine d'évacuation : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 7

Record 8 1986-09-25

English

Subject field(s)
  • Aircraft Propulsion Systems
CONT

The compartment cooling air fan is located on the APU left side just aft of the generator. The fan is driven by the accessory drive and draws air through a flapper valve mounted on the exterior surface of the APU enclosure left side. Cooling air supplied by the fan from the aft accessory compartment is blown into the system through a bifurcated duct attached to the aft side of the fan housing. This duct diverts a portion of air through the oil cooler and allows the remainder to be used for generator and APU compartment cooling. Air for cooling the generator flows through a crossover duct attached to the blast cap on the end of the generator. Air for cooling the compartment is allowed to escape into the area surrounding the APU by means of a slot in the lower surface of the generator crossover duct.

French

Domaine(s)
  • Propulsion des aéronefs
OBS

chapeau de refroidissement : terme accepté par le Comité de la terminologie des cartes de travail du DC-9.

Spanish

Save record 8

Record 9 1985-11-29

English

Subject field(s)
  • Aeroindustry
CONT

Overboard Configuration : Automatic operation in the overboard configuration opens the outside supply valve and overboard exhaust valve. The supply fan draws air from the outside and forces it into the E/E compartment and cockpit for equipment cooling. The exhaust fan provides airflow to collect the equipment cooling air and exhaust it overboard.

French

Domaine(s)
  • Constructions aéronautiques
OBS

Terme uniformisé par le CUTA opérations aériennes.

Spanish

Save record 9

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.