CALIBRATION JIG [5 records]

Record 1 - external organization data 2000-03-29

English

Subject field(s)
  • Scientific Instruments
  • Measuring Instruments (Engineering)
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
CONT

Before calibrating any specific mark and model of survey meter the calibrator shall have available for inspection and assessment a documented calibration procedure consisting of :... an identification and proof of verification of uncertainties associated with the jig, the source, any transfer standards, attenuators, and decay correction which are associated with the total uncertainty of the calibration...

French

Domaine(s)
  • Instruments scientifiques
  • Instruments de mesure (Ingénierie)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Matière qui, placée sur le trajet d'un rayonnement, provoque une atténuation appréciable.

Spanish

Save record 1

Record 2 - external organization data 1994-11-03

English

Subject field(s)
  • Scientific Instruments
  • Measuring Instruments (Engineering)
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
CONT

The meter to be calibrated shall :(1) be positioned on the jig to minimize geotropism, directional dependence, and non-uniformity of the calibration radiation beam across and through the detector volume....

French

Domaine(s)
  • Instruments scientifiques
  • Instruments de mesure (Ingénierie)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le gammamètre à étalonner doit : a) être placé sur le tréteau de manière à minimiser le géotropisme, la dépendance directionnelle et le manque d'uniformité du faisceau de rayonnement d'étalonnage à travers le volume du détecteur [...]

Spanish

Save record 2

Record 3 - external organization data 1994-11-03

English

Subject field(s)
  • Scientific Instruments
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
CONT

Calibration distance means the distance from the centre of the calibration source to the centre of the sensitive volume of the detector when both source and survey meter are correctly set up on the calibration jig.

French

Domaine(s)
  • Instruments scientifiques
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Distance d'étalonnage. Distance entre le centre de la source d'étalonnage et le centre du volume sensible du détecteur, lorsque la source et le gammamètre sont correctement placés sur le tréteau d'étalonnage.

OBS

Le tréteau de l'étalon à faisceau doit être situé : a) de manière à minimiser le balayage de rayonnement et situé au moins à 1 m du sol et de tout mur. La distance minimale entre la source et tout objet diffuseur doit être de 0,5 m; b) dans une aire libre des interférences de toute autre source de rayonnements ionisants que l'étalon [...]

Spanish

Save record 3

Record 4 - external organization data 1994-10-27

English

Subject field(s)
  • Metrology and Units of Measure
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
DEF

... a change in instrument response with respect to orientation of the instrument for constant exposure rate, excluding geotropism.

CONT

The meter to be calibrated shall :(1) be positioned on the jig to minimize geotropism, directional dependence, and non-uniformity of the calibration radiation beam across and through the detector volume....

French

Domaine(s)
  • Unités de mesure et métrologie
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Modification de la réponse de l'appareil selon son orientation par rapport au débit d'exposition constant, non compris le géotropisme.

CONT

Le gammamètre à étalonner doit : a) être placé sur le tréteau de manière à minimiser le géotropisme, la dépendance directionnelle et le manque d'uniformité du faisceau de rayonnement d'étalonnage à travers le volume du détecteur [...]

Spanish

Save record 4

Record 5 - external organization data 1994-10-27

English

Subject field(s)
  • Metrology and Units of Measure
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
DEF

... the distance from the centre of the calibration source to the centre of the sensitive volume of the detector when both source and survey meter are correctly set up on the calibration jig.

French

Domaine(s)
  • Unités de mesure et métrologie
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Distance entre le centre de la source d'étalonnage et le centre du volume sensible du détecteur, lorsque la source et le gammamètre sont correctement placés sur le tréteau d'étalonnage.

Spanish

Save record 5

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: