DECAY HEAT REMOVAL SYSTEM [3 records]

Record 1 2017-04-07

English

Subject field(s)
  • Nuclear Power Stations
  • Nuclear Plant Safety
  • Nuclear Fission Reactors
CONT

The Concepts of the Next Generation Marine Reactors.... In their designs, reduction of plant size and weight and improvement of safety characteristics are enhanced by employment of a wet containment system, which will always assure core flooding and heat removal of decay by natural convection.

CONT

... several tests have to be run to validate the smooth operations of the compartment design, i.e. to check that the corium spreads correctly, that the compartment materials hold up, that flood cooling is efficient and that the fusible plate closure works.

PHR

Core flooding (tank), emergency core flooding system, gravity-driven core flooding line.

French

Domaine(s)
  • Centrales nucléaires
  • Sûreté des centrales nucléaires
  • Réacteurs nucléaires de fission
CONT

La séquence accidentelle qui sous-tend ce concept de récupérateur peut se résumer ainsi. Suite à un accident par perte de réfrigérant primaire, il y a fusion du cœur du réacteur. Les matériaux en fusion progressent alors vers le fond de cuve où ils s'accumulent pour former un bain dont la température est d'environ 2500 à 3000 °C. Le corium, qui a conservé en son sein les éléments radioactifs non volatiles, s'échauffe sous l'effet de la puissance résiduelle. Si le refroidissement est insuffisant, notamment s'il est impossible de réinjecter de l'eau dans le circuit primaire, l'échauffement excessif peut entraîner le percement de la cuve. Dans cette hypothèse, la décharge de corium se fait dans le puits de cuve aménagé en un réceptacle depuis lequel on cherche à accumuler et à retenir de façon provisoire au moyen d'une porte fusible la totalité du corium en provenance de la cuve. Quand la porte fusible cède, l'étalement du corium se fait dans une chambre [...] exempte d'eau. L'idée maîtresse de l'absence d'eau à ce stade est d'éviter le risque d'une explosion vapeur. Enfin, après étalement, le corium est noyé sous eau de manière à favoriser un refroidissement de longue durée. [...] Pour valider le bon fonctionnement de concept de récupérateur, il faut [...] procéder à plusieurs vérifications, à savoir l'étalement correct du corium, la bonne tenue des matériaux constituants le récupérateur, l'efficacité du refroidissement par noyage du corium étalé, le fonctionnement de la porte fusible.

CONT

Étude du noyage et dénoyage d'un lit de débris dans un réacteur nucléaire : il s'agit d'étudier l'injection d'eau dans un corium en cours de destruction, afin de modéliser les scénarios de maîtrise d'accidents de cœur de réacteur nucléaire.

Spanish

Save record 1

Record 2 2009-10-29

English

Subject field(s)
  • Water Supply
  • Nuclear Fission Reactors
CONT

Emergency Feedwater(EFW) System. The emergency heat removal function is accomplished by the EFW system. The system provides an independent supply of feedwater to the steam generators to remove decay and sensible heat to cool down the reactor following a total loss of the main and emergency feedwater systems.

French

Domaine(s)
  • Alimentation en eau
  • Réacteurs nucléaires de fission
CONT

Circuit d'eau d'alimentation d'urgence (SEU). La fonction de refroidissement d'urgence est accomplie par le circuit SEU. Le circuit approvisionne indépendamment les générateurs de vapeur en eau d'alimentation pour éliminer la chaleur de désintégration et sensible afin de refroidir le réacteur après une perte totale des circuits d'eau d'alimentation principaux et d'urgence.

Spanish

Save record 2

Record 3 1980-03-06

English

Subject field(s)
  • Nuclear Power Stations
DEF

A system comprising diesel-driven pumps capable of providing cooling water to remove decay heat from steam generators, moderator heat exchangers and primary heat transport system following loss of the normal heat removal system.

French

Domaine(s)
  • Centrales nucléaires
DEF

(...) système comprenant des pompes à moteur diesel, capable de fournir de l'eau de refroidissement pour éliminer la chaleur résiduelle des générateurs de vapeur, des échangeurs de chaleur du modérateur et du circuit caloporteur, à la suite d'une défaillance du [circuit d'évacuation de la] chaleur.

Spanish

Save record 3

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: