FREQUENCY AMBIGUITY [5 records]

Record 1 2017-04-21

English

Subject field(s)
  • Ultrasonography
  • Cardiovascular System
CONT

The principal advantage of pulsed Doppler is range resolution, or the ability to sample blood flow in a small, specific area whose location and depth can be varied. A disadvantage of pulsed Doppler, however, is that there are limits to the maximum frequency shifts that can be unambiguously displayed at any given depth. To avoid range ambiguity, the ultrasound pulse must travel down to the selected depth and back before the next pulse can enter the heart. Therefore, the PRF [pulse repetition frequency] or sampling rate is limited at each depth.

French

Domaine(s)
  • Ultrasonographie
  • Système cardio-vasculaire
DEF

Technique échographique d'exploration vélocimétrique du cœur et des vaisseaux utilisant l'effet doppler [où] l'émission des ondes ultrasonores est faite en mode pulsé et le signal doppler est obtenu par l'analyse des échos provenant d'une profondeur sélectionnée par l'utilisateur.

OBS

Une même céramique est alternativement émettrice et réceptrice. L’émission des ultrasons est discontinue et chaque brève impulsion est suivie d’une période d’écoute pendant laquelle la sonde recueille les échos qui lui parviennent. Une fenêtre de mesure réglable en profondeur permet de sélectionner de façon précise le volume de la cible à étudier, ce qui évite la superposition des informations. Le mode doppler pulsé est couplé à l'échographie en mode B sur laquelle se fait le repérage de la zone de mesure. Le résultat est représenté sur l'écran sous la forme du tracé du spectre doppler. Le signal doppler appliqué à un haut parleur est également perçu sous forme audible.

Spanish

Save record 1

Record 2 2010-01-29

English

Subject field(s)
  • Radar, Radio Guidance and Goniometry
  • Air Navigation Aids
  • Marine and River Navigation Aids
CONT

To reduce the ambiguity, the decca system employs a means of lane identification. This is done, in effect by measuring the phase identification between the signals from the stations and the frequency "f"(=14. 0 kHz).

French

Domaine(s)
  • Radar, radioguidage et radiogoniométrie
  • Aides à la navigation aérienne
  • Aides à la navigation fluviale et maritime

Spanish

Campo(s) temático(s)
  • Guía radárica, radioguía y radiogoniometría
  • Ayuda para la navegación aérea
  • Ayuda a la navegación marítima y fluvial
Save record 2

Record 3 2006-05-01

English

Subject field(s)
  • Radar, Radio Guidance and Goniometry
  • Remote Sensing
DEF

A ghost-like form that occurs when returns are received simultaneously from previously (or successively) transmitted pulses and from the illuminated region.

CONT

This range ambiguity is caused as a result of the high pulse repetition frequency.

OBS

range ambiguity: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

French

Domaine(s)
  • Radar, radioguidage et radiogoniométrie
  • Télédétection
DEF

Effet fantôme causé par le captage simultané de signaux provenant d'impulsions reçues antérieurement ou successivement et du signal rétrodiffusé par la zone cible.

OBS

Le nombre de pics [ou pointes de bruit] diminue avec la puissance de bruit. S'il y a cible, on peut se tromper cependant, il peut y avoir ambiguïté sur la distance. Il reste une certaine probabilité de fausse alarme.

OBS

ambiguïté distance : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

Spanish

Save record 3

Record 4 1996-10-30

English

Subject field(s)
  • Acoustics (Physics)
  • Telecommunications Transmission
  • Video Technology
DEF

An ambiguity in the frequency represented by sampled seismic data. Where there are fewer than two samples per cycle, an input signal at one frequency yields the same sample values as, and hence appears to be, another frequency at the output of the system. Half of the frequency of sampling is called the "folding" or "Nyguist" frequency, fN;a frequency larger than this, fN+Y, appears to be the smaller frequency, fN-Y. The two frequencies are "aliases" of each other.

Key term(s)
  • folding frequency
  • Nyquist frequency

French

Domaine(s)
  • Acoustique (Physique)
  • Transmission (Télécommunications)
  • Vidéotechnique
DEF

Composante en miroir du signal, résultant d'un échantillonnage à une fréquence inférieure à la fréquence de Nyquist.

OBS

L'échantillonnage du signal provoque une ambiguïté sur les fréquences, à cause des phénomènes de repliement du spectre. [...] On peut montrer qu'il n'y a pas de phénomène de repliement si l'on s'arrange pour ne pas avoir de signal à des fréquences supérieures à la fréquence de Nyquist (moitié de la fréquence d'échantillonnage).

Spanish

Save record 4

Record 5 1994-05-31

English

Subject field(s)
  • Mathematical Geography
  • Remote Sensing
DEF

The difference between the phase of the incoming Doppler-shifted GPS carrier and the phase of a nominally constant reference frequency generated in the receiver.

OBS

For static positioning, the reconstructed carrier phase is sampled at epochs determined by a clock in the receiver. The reconstructed carrier phase changes according to the continuously integrated Doppler shift of the incoming signal, biased by the integral of the frequency offset between the satellite and receiver reference oscillators. The reconstructed carrier phase can be related to the satellite-to-receiver range, once the initial range(or phase ambiguity) has been determined. A change in the satellite-to-receiver range of one wavelength of the GPS carrier(19 cm for L1) will result in a one-cycle change in the phase of the reconstructed carrier.

OBS

Term and definition provided by the Canadian Hydrographic Service.

French

Domaine(s)
  • Géographie mathématique
  • Télédétection
DEF

La différence entre la phase de la porteuse GPS dont la fréquence est décalée par effet Doppler et la phase d'une fréquence de référence nominalement constante produite par le récepteur.

OBS

Aux fins du positionnement statique, la phase reconstituée de la porteuse est échantillonnée suivant des époques déterminées d'après une horloge dans le récepteur. La phase reconstituée de la porteuse varie en fonction du décalage Doppler, intégré de manière ininterrompue, modifié par l'intégrale du décalage de fréquence entre les oscillateurs de référence du récepteur et du satellite. La phase reconstituée de la porteuse peut être mise en relation avec la distance satellite-récepteur une fois la distance initiale (ambiguïté de phase) déterminée. Une modification de la distance satellite-récepteur égale à une longueur d'onde de la porteuse du GPS (19 cm pour L1) résulte en une modification égale à un cycle de la phase reconstituée de la porteuse.

Spanish

Save record 5

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: