GAS CHROMATOGRAPHIC ANALYSIS [5 records]

Record 1 2025-06-10

English

Subject field(s)
  • Physics
  • Analytical Chemistry
CONT

GC is a common type of chromatography often used in chemical separations and analysis. GC can be defined as a chromatographic method in which the mobile phase is a gas.

OBS

In gas chromatography, the stationary phase can either be liquid or solid.

Key term(s)
  • vapour-phase chromatography
  • vapor-phase chromatography

French

Domaine(s)
  • Physique
  • Chimie analytique
CONT

La CPG est une méthode de séparation sur colonne de substances volatiles (ou rendues volatiles) véhiculées par un gaz inerte appelé gaz vecteur.

OBS

Dans la chromatographie en phase gazeuse, la phase stationnaire peut être liquide ou gazeuse.

Spanish

Campo(s) temático(s)
  • Física
  • Química analítica
DEF

Sistema de separación de los componentes de una mezcla entre sí por volatilización de la muestra en una corriente de gas portador.

Save record 1

Record 2 2014-07-21

English

Subject field(s)
  • Analytical Chemistry
DEF

The gas or liquid mixture injected into the chromatographic system for separation and analysis.

PHR

Sample concentration, introduction, weight.

Key term(s)
  • specimen

French

Domaine(s)
  • Chimie analytique
CONT

[...] l'aménagement de ce circuit gazeux évite à l'échantillon vaporisé de se détendre en amont de la tête de colonne et permet ainsi son introduction quasi instantanée dans la colonne.

PHR

Échantillon ionique, ionisable, moyennement polaire, non polaire, polaire.

Key term(s)
  • spécimen

Spanish

Campo(s) temático(s)
  • Química analítica
DEF

Muestra de un terreno, material, producto industrial o manufacturado, que se extrae para someterlo a ensayos mecánicos, químicos o de otra índole.

Save record 2

Record 3 2010-12-23

English

Subject field(s)
  • Biological Sciences
  • Analytical Chemistry
DEF

Instrument used to monitor and quantify the products eluted from a chromatography column. Techniques used are based on the physical, chemical or biological properties of the molecules and may involve prior conversion by chemical or enzymic means to produce a coloured or fluorescent complex. Physical methods include the use of spectrophotometers, colorimeters, spectrophotofluorometers, refractometers, polarimeters, etc.

CONT

Biological molecules may be monitored using enzyme-linked reactions specific for the required class of compound. Such detectors often include a flow cell so that the fluid passes continuously from the column through the detector. Several types of detector have been developed specifically for use with gas/liquid chromatographs. These include flame ionization and electron capture devices or, where information is required on the exact structure of the compounds, a mass spectrometer. Many are linked to microprocessors for control of the chromatographic analysis, as well as direct computation of results.

French

Domaine(s)
  • Sciences biologiques
  • Chimie analytique
DEF

Appareil servant à déceler, à révéler la présence d'un corps dans un échantillon.

CONT

Les détecteurs en chromatographie [...] mettent en évidence les constituants du mélange. Un bon détecteur doit être stable, sensible, linéaire, pratique d'emploi et ne doit pas altérer les séparations réalisées par la colonne.

Spanish

Campo(s) temático(s)
  • Ciencias biológicas
  • Química analítica
Save record 3

Record 4 2004-08-27

English

Subject field(s)
  • Measuring Instruments
  • Environmental Studies and Analyses
  • Analytical Chemistry
CONT

... sampling into silica gel tube, 2, 4-dinitrophenylhydrazine impregnated passive diffusion badge or filter cassette and subsequent gas chromatographic or high performance liquid chromatographic analysis provides more accurate determination of airborne glutaraldehyde concentration...

CONT

Nitschke et al (1998) analysed indoor nitrogen dioxide levels by selecting a cohort of 129 asthmatics and ensuring they wore diffusion badge monitors while indoor gas appliances are being used, which is seen as potentially the greatest period of exposure. Levels were expressed at time-average nitrogen dioxide concentration, because daily badge exposure times differed (mean 4.5 hours, sd 2.4).

CONT

The exposure of each child to nitrogen dioxide both at home and in the classroom was measured using passive diffusion badge monitors.

French

Domaine(s)
  • Appareils de mesure
  • Études et analyses environnementales
  • Chimie analytique
CONT

Les cétones sont piégées sur un badge à diffusion passive ou dans un tube rempli de charbon actif [...] et dosées par chromatographie en phase gazeuse avec détection par ionisation de flamme avec désorption sur charbon actif [...]

CONT

Le département «Hygiène - Toxicologie - Détection» dispose d'une gamme complète pour le contrôle de l'air de lieu de travail, l'air intérieur de l'habitat et l'air ambiant en gaz toxique, poussières, aérosol, métaux lourds, silicie, HAP, BTX, amiante, fibre, aérobiocontaminant, bactérie, organisme microbiologique, moisissure, pollen, échantillonneur individuel (badge passif GABIE et CIP10M pour les polluants microbiologiques (spore, endotoxine), bactérie, pollen, moisissures, capteur individuel de poussières CIP10, pompe de prélèvement), station et pompe de prélèvement pour l'air ambiant (PM10, PM2.5), détecteur de gaz toxique, ainsi que tous les accessoires nécessaires pour piéger du polluant lors de prélèvement [...]

Spanish

Save record 4

Record 5 1996-05-13

English

Subject field(s)
  • Analytical Chemistry
CONT

Kaye adapted a Beckman far-ultraviolet DK-2 spectrophotometer as a gas chromatographic effluent detector to record the spectra of eluted, absorbing materials. Using heated flow-through cells... coupled directly to the thermal conductivity cell' s outlet, he found that absorptivities of most organic vapors were sufficiently large to permit quantitative analysis, and in some instances identification, where specific absorption patterns could be attributed directly to a functional group in certain molecular species. Furthermore, the sensitivity of the far-ultraviolet detector for many compounds possessing intense absorption bands exceeds that of the normal thermal conductivity detector and, in some cases, the hydrogen flame ionization detector.

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 5

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: