TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

GAS FILLED DETECTOR [3 records]

Record 1 2003-02-26

English

Subject field(s)
  • Scientific Instruments
  • Atomic Physics
CONT

The Transition Radiation Detector... consists of six polyethylene fiber radiator blankets, each with a multi-wire proportional chamber MWPC(filled with a Xenon-methane gas mixture) attached underneath. When a charged particle travels through an interface between materials of different dielectric constants, radiation(in the form of X-rays) is generated with an intensity proportional to the relativistic Lorentz factor gamma of the particle.

French

Domaine(s)
  • Instruments scientifiques
  • Physique atomique

Spanish

Save record 1

Record 2 2001-05-17

English

Subject field(s)
  • Chemistry
  • Scientific Instruments
  • Milling and Cereal Industries
CONT

Chemical spot tests use glass detector tubes to determine concentrations of a wide range of gases in air. The tubes are filled with a chemical that reacts with a particular gas to give a colour development as air is drawn through the tube. Chemical spot testing equipment is available from at least three manufacturers.

French

Domaine(s)
  • Chimie
  • Instruments scientifiques
  • Minoterie et céréales
CONT

Ces tubes, en verre, permettent de déterminer les concentrations d'une grande variété de gaz dans l'air. Les tubes contiennent des produits chimiques qui réagissent avec le gaz qu'on y introduit à l'aide d'un soufflet, en donnant une réaction colorée dont la longueur est proportionnelle à la concentration du gaz. Au moins trois fabricants produisent ce genre de tube.

Spanish

Save record 2

Record 3 1996-05-13

English

Subject field(s)
  • Analytical Chemistry
CONT

A simple arrangement of two cavities in series showed the feasibility of detecting traces of one gas in another. A klystron was used to generate microwave power which was fed through a wave guide to a transmission-type cavity. Another cavity was mounted in series with and tuned to the same frequency as the first; both cavities were identical except that the second had a gas inlet and outlet ports. From this measuring cell, its microwave energy was sent to a crystal detector. By frequency-modulating the klystron with a 50-cps sine wave voltage on the repeller, a burst of energy passes to the detector each time the generator frequency equals that of the cavities. The detector current is amplified and measured with an oscilloscope. At the beginning of the run, the two cavities are filled with the nitrogen carrier gas and, if the composition in one of the cavities is changed, its electrical size will change... causing a decrease of current from the detector.

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 3

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: