TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

HARMONIC ANALYSIS [8 records]

Record 1 2024-06-14

English

Subject field(s)
  • Medical Imaging
CONT

Unlike the DT [diffusion tensor] model, FBA relies on a spherical harmonic representation of diffusion that can more readily represent complex multi-fiber geometry, allowing for anatomically-informative metrics to be separately estimated for distinct fiber populations within a voxel. Specifically, fixel-based analysis utilizes constrained spherical deconvolution(CSD) to estimate fiber orientation distribution functions(fODFs) within each voxel, and then segments fODFs into directionally distinct lobes associated with distinct fiber populations("fixels") within a voxel.

Key term(s)
  • fixel based analysis

French

Domaine(s)
  • Imagerie médicale

Spanish

Save record 1

Record 2 2015-02-12

English

Subject field(s)
  • Nervous System
CONT

In the last decades, imaging membrane potential has become a fruitful approach to study neural circuits, especially in invertebrate preparations with large, resilient neurons. At the same time, particularly in mammalian preparations, voltage imaging methods suffer from poor signal to noise and secondary side effects, and they fall short of providing single-cell resolution when imaging of the activity of neuronal populations. As an introduction to these techniques, we briefly review different voltage imaging methods(including organic fluorophores, SHG [second harmonic generation] chromophores, genetic indicators, hybrid, nanoparticles, and intrinsic approaches) and illustrate some of their applications to neuronal biophysics and mammalian circuit analysis.

French

Domaine(s)
  • Système nerveux
CONT

Les neurobiologistes ont besoin de moyens plus efficaces et moins invasifs pour observer les circuits cérébraux, où des signaux électriques passent d'un neurone à l'autre. [...] Imagerie de voltage. Dans cette technique, on implante un colorant au sein du neurone afin de déterminer si la cellule est active. Il constitue un capteur, qui émet une fluorescence lorsque le champ électrique à travers la membrane cellulaire change de polarité; cela se produit quand un signal électrique passe.

Spanish

Save record 2

Record 3 2011-05-25

English

Subject field(s)
  • Statistical Graphs and Diagrams
  • Physics
  • Combinatorial Analysis (Mathematics)
CONT

3-Phase precision power meter … Analysis of the harmonics … When optimizing a circuit for lowest emission of harmonics, the effects of a modification of the circuitry can be monitored immediately … the phasor(Fresnel)-diagram of each harmonics can be displayed. … the harmonic frequency spectrum of a frequency inverter [can be seen].

French

Domaine(s)
  • Diagrammes et graphiques (Statistique)
  • Physique
  • Analyse combinatoire (Mathématiques)
CONT

Les circuits électriques en régime permanent sinusoïdal. Grandeurs sinusoïdales […] Représentation de Fresnel. Puisque les phaseurs sont des nombres complexes, il est possible de les représenter graphiquement dans le plan complexe sous forme de demi-droites partant de l’origine si et seulement si ils ont la même pulsation. Ce mode de représentation, appelé diagramme de Fresnel, permet de mettre en évidence les déphasages relatifs des différentes grandeurs sinusoïdales et d’effectuer des opérations élémentaires (addition, soustraction).

Spanish

Save record 3

Record 4 2008-03-18

English

Subject field(s)
  • Nervous System
  • Electrodiagnosis
CONT

A study of the photoconvulsive response to photic activation in a single subject was undertaken using the methods of generalized harmonic analysis. This paper presents such methods and the preliminary results of their application to the problem of defining the mechanisms of moment to moment variation in susceptibility to epileptic activation by intermittent photic stimulation.

OBS

EEG (electroencephalograph).

French

Domaine(s)
  • Système nerveux
  • Électrodiagnostiques
CONT

Avec la méthode d'analyse harmonique globale, on a étudié, chez un sujet, la réponse photoconvulsive. Ce travail présente les premiers résultats obtenus par ces méthodes appliquées à l'étude de la définition des mécanismes impliqués, à chaque instant, dans les variations de la susceptibilité à l'activation photoconvulsive.

OBS

EEG (électroencéphalographe).

Spanish

Campo(s) temático(s)
  • Sistema nervioso
  • Electrodiagnóstico
Save record 4

Record 5 2003-01-30

English

Subject field(s)
  • Audio Technology
DEF

Of a complex waveform, one of the components with a frequency equal to a multiple of the fundamental frequency.

OBS

The analysis of a complex waveform into its harmonic components can be carried out mathematically by Fourier analysis or practically by use of a harmonic analyser.

French

Domaine(s)
  • Électroacoustique
DEF

Terme du développement d'une fonction périodique en série de Fourier.

Spanish

Campo(s) temático(s)
  • Electroacústica
DEF

Componente de orden mayor que 1 en la serie de Fourier de una cantidad periódica.

OBS

La serie de Fourier es la serie trigonométrica.

Save record 5

Record 6 2000-11-20

English

Subject field(s)
  • Electrical Measurements
CONT

Harmonic Current/Voltage Analysis. Power quality problems are on the increase due to non-linear loads from electronic equipment such as personal computers, electronic ballasts, laser printers, welders, and adjustable speed drives.

Key term(s)
  • ballast harmonic current

French

Domaine(s)
  • Mesures électriques
OBS

harmonique de courant : terme souvent utilisé au pluriel (harmoniques de courant).

Key term(s)
  • harmoniques de courant
  • ballast et douille d'éclairage
  • harmoniques de ballast
  • harmonique de ballast

Spanish

Save record 6

Record 7 1997-12-02

English

Subject field(s)
  • Various Proper Names
  • Geophysics
OBS

The Canadian Geomagnetic Reference Field(CGRF) is a mathematical model of the geomagnetic field over Canada. It is produced by carrying out a spherical cap harmonic analysis on numerous observations of the magnetic field made on the ground, at sea, in the air, and a satellite altitudes between 1960 and 1994. The latest CGRF is for 1995, but contains time terms that enable it to be used over the time interval 1960 to 2000.

French

Domaine(s)
  • Appellations diverses
  • Géophysique
OBS

Le Champ de référence géomagnétique du Canada (CGRF) est un modèle mathématique du champ géomagnétique du Canada. Il a été produit grâce à l'analyse des harmoniques de la calotte sphérique à partir des nombreuses observations du champ magnétique qui ont été effectuées au sol, en mer, dans les airs et aux altitudes de satellite entre 1960 et 1994. Le modèle du CGRF le plus récent date de 1995, mais il contient des équations temporelles qui permettent de l'utiliser pour différents intervalles de temps entre 1960 et l'an 2000.

Spanish

Save record 7

Record 8 1976-06-19

English

Subject field(s)
  • Hydrology and Hydrography
OBS

see Harmonic Analysis

French

Domaine(s)
  • Hydrologie et hydrographie

Spanish

Save record 8

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: