LP TURBINE [5 records]

Record 1 2011-10-03

English

Subject field(s)
  • Turbines
CONT

The turbine consists of one HP stage and three LP stages, each driving their own compressors through concentric shafts.

French

Domaine(s)
  • Turbines
CONT

ensemble tournant compresseur-turbine - réacteur double flux à soufflante avant [...] comprenant 2 attelages compresseur-turbine à arbres concentriques.

OBS

arbre concentrique : Terme uniformisé par le CUTA - Opérations aériennes.

Spanish

Save record 1

Record 2 - external organization data 2005-11-09

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

Before entering the LP [low-pressure] turbine, the steam passes through intercept valves. In a fashion similar to the emergency stop valve, these valves shut off steam to the LP turbine in an emergency. Steam passes through the normally open intercept valve, passes through the low-pressure turbine, and is then exhausted to the condenser...

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Avant de pénétrer dans la turbine basse-pression, la vapeur doit traverser des vannes d'interception. Tout comme la vanne d'arrêt d'urgence, ces vannes permettent, en cas d'urgence, d'isoler la turbine basse-pression. En condition normale, la vapeur franchit la vanne d'interception ouverte, s'écoule dans la turbine basse-pression d'où elle ressort pour passer au condenseur.

Spanish

Save record 2

Record 3 - external organization data 2005-11-08

English

Subject field(s)
  • Pumps
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

Given a diagram, label the following components, show the main steam and water connection between them, and indicate the direction of flow : boiler(steam generator), safety valve, atmospheric steam discharge valve(ASDV), emergency stop valve, governor valve, HP turbine, moisture separator, reheater, LP turbine, condenser, condensate extraction pump, feedheaters, deaerator, and boiler feed pump.

French

Domaine(s)
  • Pompes
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Sur un schéma, identifier les éléments qui suivent, indiquer les conduites de vapeur et d'eau entre eux, et préciser la direction de l'écoulement : générateur de vapeur, soupape de sécurité, vanne de décharge de la vapeur dans l'atmosphère, vanne d'arrêt d'urgence, vanne de régulation, turbine haute-pression, séparateur d'humidité, réchauffeur, turbine basse-pression, condenseur, pompe d'extraction du condensat, réchauffeurs d'eau, dégazeurs, pompe d'alimentation du générateur de vapeur.

Spanish

Save record 3

Record 4 - external organization data 2005-11-08

English

Subject field(s)
  • Heating
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

The boiler feed pumps(BFP) take suction from the deaerator storage tank and raise the feedwater pressure to between 4 and 7 MPa. The pump discharges the high-pressure feedwater to the high-pressure(HP) feedheaters. The HP feedheaters heat the feedwater to about 170°C. HP feedheater operation and construction are similar to that of the LP feedheaters. Extraction steam from the HP turbine normally supplies the heating medium.

Key term(s)
  • high pressure feedheater

French

Domaine(s)
  • Chauffage
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Cette pompe décharge l'eau d'alimentation sous pression dans les réchauffeurs à haute pression. Ces réchauffeurs poussent la température de l'eau d'alimentation jusqu'à environ 170 °C. Le fonctionnement et la construction du réchauffeur à haute pression sont analogues à ceux du réchauffeur à basse pression. La source normale de chaleur est la vapeur soutirée de la turbine haute-pression.

Spanish

Save record 4

Record 5 1982-12-17

English

Subject field(s)
  • Aeroindustry
CONT

The clapper on the fan will be moved out, an increased capacity IP compressor and revised cooling offtake will be fitted and there will be a new IP and LP turbine module.

French

Domaine(s)
  • Constructions aéronautiques
CONT

Les ailettes antivibratoires des pales de soufflante seront déplacées vers l'extérieur et le moteur sera doté d'un compresseur MP de capacité accrue, d'une prise de refroidissement modifiée et d'un nouvel ensemble turbine MP/LP.

Spanish

Save record 5

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: