TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

METHOD CALIBRATION [22 records]

Record 1 2019-11-28

English

Subject field(s)
  • Transformation of Momentum (Mechanical Components)
  • Fueling Systems (Motor Vehicles)
CONT

What is "metering rod technology"? It is a method of changing the calibration of the carburetor in response to different stimuli by inserting a movable tapered rod through the main metering jet. … This method, consisted of a vacuum piston held in a certain position by vacuum, which would change position when vacuum was reduced by additional throttle opening by the tensioned spring pressing against the piston.

French

Domaine(s)
  • Transformations de mouvements (Composants mécaniques)
  • Alimentation (Véhicules automobiles)
CONT

Retirez l'ensemble du piston à vide du corps du carburateur.

Spanish

Save record 1

Record 2 2017-03-31

English

Subject field(s)
  • Scientific Research Methods
  • Analytical Chemistry
CONT

Recovery of the analyte over the entire analytical process is determined from matrix spikes, spiked blanks, and surrogate spikes.... The spiked method blank is a separate aliquot of the same reagent water used for the method blank that is spiked with the compound of interest at a concentration as close as possible to the concentration of the mid-level calibration standard.

French

Domaine(s)
  • Méthodes de recherche scientifique
  • Chimie analytique
CONT

Le taux de récupération d'une substance à analyser au cours de l'ensemble du processus d'analyse est déterminé à partir d'échantillons de matrice et de blancs enrichis avec des concentrations connues de la substance à analyser et d'analogues. [...] Un blanc de méthode enrichi est une fraction de la même eau que celle utilisée pour le blanc de méthode à laquelle on ajoute la substance à analyser à une concentration aussi proche que possible de celle de l'étalon de concentration intermédiaire.

Spanish

Save record 2

Record 3 2016-06-27

English

Subject field(s)
  • General Scientific and Technical Vocabulary
  • Metrology and Units of Measure
  • Scientific Measurements and Analyses
DEF

A material or a substance [having] one or more... property values... sufficiently homogeneous and well established to be used for the calibration of an apparatus, for the assessment of a measurement method or for assigning values to materials.

OBS

A reference material may be in the form of a pure or mixed gas, liquid or solid. Examples are water for the calibration of viscometers, sapphire as a heat-capacity calibrant in calorimetry, and solutions used for calibration in chemical analysis.

OBS

In the field of gas analysis, a reference material is a gas mixture of known composition and/or properties which is traceable by one or more steps to national or international standards.

OBS

reference material; RM: term and abbreviation standardized by ISO in 2014.

French

Domaine(s)
  • Vocabulaire technique et scientifique général
  • Unités de mesure et métrologie
  • Mesures et analyse (Sciences)
DEF

Matériau ou substance dont une ou plusieurs des propriétés sont suffisamment homogènes et bien définies pour servir de base à l'étalonnage d’un appareil, à l'évaluation d'une méthode de mesure ou à l'attribution de valeurs à des matériaux.

OBS

Un matériau de référence peut se présenter sous la forme d'un gaz, d'un liquide ou d'un solide, pur ou composé. Des exemples sont l'eau pour l'étalonnage des viscosimètres, le saphir qui permet d'étalonner la capacité thermique en calorimétrie et les solutions utilisées pour l'étalonnage dans l'analyse chimique.

OBS

Dans le domaine de l'analyse des gaz, un matériau de référence est un mélange de gaz de composition et/ou de propriétés connues qui est raccordable en une ou plusieurs étapes à des étalons nationaux ou internationaux.

OBS

matériau de référence; MR : terme, abréviation et définition normalisés par l'ISO en 2014.

OBS

matériau de référence : terme normalisé par l'AFNOR en 1984.

Spanish

Save record 3

Record 4 2013-10-18

English

Subject field(s)
  • Remote Sensing
CONT

The empirical line method is an atmospheric correction technique that provides an alternative to radiative transfer modelling approaches. It offers a relatively simple means of surface reflectance calibration, providing that a series of invariant-in-time calibration target measurements are available. This technique has been applied with variable success to both airborne data and coarser spatial resolution satellite sensor data.

French

Domaine(s)
  • Télédétection

Spanish

Save record 4

Record 5 2013-01-31

English

Subject field(s)
  • Scientific Measurements and Analyses
  • Environmental Studies and Analyses
DEF

An analyte-free matrix that is carried through all or part of the analytical process for the purpose of identifying contamination introduced during analysis.

OBS

Types of laboratory blanks include method blanks(carried through the entire preparation and analysis sequence), calibration blanks,(matrix-matched reagent water used for calibration), and storage blanks(placed in sample storage areas).

French

Domaine(s)
  • Mesures et analyse (Sciences)
  • Études et analyses environnementales
CONT

Des blancs de laboratoire ont de plus été réalisés sur les sols et sur l'eau souterraine. Ces blancs de laboratoire ont dans chacun des cas montré que les valeurs obtenues se situent à l'intérieur de l'écart acceptable et ce, lors du contrôle certifié.

Spanish

Save record 5

Record 6 2012-01-26

English

Subject field(s)
  • Railroad Maintenance
  • Braking Devices (Mechanical Components)
DEF

Train brake leakage test method that uses the brake pipe flow indicator/meter.

CONT

The Air Flow Method utilizes air flow into the brake pipe as shown on the Brake Pipe Flow Indicator along with a specified pressure at the rear of the train to qualify trains with respect to testing of Air Brakes.... The Air Flow Method will only be performed on freight trains with leading engines equipped with a pressure-maintaining feature and a Brake Pipe Flow Indicator which has been marked with an orange calibration line.

French

Domaine(s)
  • Entretien (Équipement ferroviaire)
  • Freins (Composants mécaniques)
DEF

Méthode d'essai d'étanchéité de frein de train qui emploie l'indicateur de débit de conduite générale.

Spanish

Save record 6

Record 7 2011-12-14

English

Subject field(s)
  • Analytical Chemistry
CONT

J. Estimated value; value may not be accurate. This code [J] is to be used in the following instances :... This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. The reported value should be considered estimated.

French

Domaine(s)
  • Chimie analytique
CONT

Les qualificateurs [sont] différents points de vue par lesquels nous décrivons d'une façon utilisable, par nous, les entités-objets que nous avons créées. Ces qualificateurs sont les moyens d'observation et de mesure, biologiques ou instrumentaux, dont nous disposons. Il n'y a qu'une qualification par mesure et celle-ci n'est pas répétable car, généralement, l'entité-objet a changé.

Spanish

Save record 7

Record 8 2010-11-03

English

Subject field(s)
  • Trade Names
  • Hand Tools
DEF

A portable electric engraving and cutting implement.

OBS

The Vibro-Tool provides a simple method of permanently marking glass or metal objects. Perfectly balanced to fit the hand and light weight(1 lb.), the Vibro-Tool handles as easily as writing with a pencil. Marking is accomplished mechanically by vibrations of the marking tool-120 reciprocal strokes per second-consumes less current than a 60 watt light bulb. The use of the Vibro-Tool ranges from engraving simple identification numbers and chemical nomenclature on bottles or slides to engraving special calibration markings on equipment and experimental dials, gauges and measures. A few suggested uses include marking test tubes, beakers, jars, flasks, watch glasses, stock bottles, microscope slides, reagent bottles, manometric scales, metallurgical specimens, etc.

OBS

Vibro-tool: A trademark of Acme Burgess, Inc., Grayslake, Illinois.

French

Domaine(s)
  • Appellations commerciales
  • Outillage à main
OBS

Vibro-Tool : Marque déposée de la compagnie Acme Burgess, Inc., Grayslake, Illinois.

Spanish

Save record 8

Record 9 2010-05-11

English

Subject field(s)
  • Audio Technology
  • Radio Broadcasting
  • Television (Radioelectricity)
DEF

Microphone whose response is determined accurately by means of a primary calibration method.

French

Domaine(s)
  • Électroacoustique
  • Radiodiffusion
  • Télévision (Radioélectricité)
DEF

Microphone dont la réponse, dans des conditions de fonctionnement spécifiées, est connue avec précision.

Spanish

Campo(s) temático(s)
  • Electroacústica
  • Radiodifusión
  • Televisión (Radioelectricidad)
Save record 9

Record 10 2009-11-17

English

Subject field(s)
  • Analytical Chemistry
  • Atomic Physics
  • Electromagnetic Radiation
  • Radiological Physics (Theory and Application)
DEF

[A gamma spectrometry method used] to determine the isotopic composition of plutonium [or uranium] samples without external efficiency calibration.

OBS

Its major drawback arises from the fact that Pu-242 does not show useful gamma rays. This isotope abundance has therefore to be estimated using isotope correlation techniques. However, it is a non destructive technique which has proven its capability in field application as well as under laboratory conditions.

Key term(s)
  • multiple-group analysis

French

Domaine(s)
  • Chimie analytique
  • Physique atomique
  • Rayonnements électromagnétiques
  • Physique radiologique et applications
CONT

Les applications principales de la spectrométrie gamma concernent l'estimation de compositions isotopiques (uranium et plutonium) et le domaine de la caractérisation radiologique d'objets irradiants. Elles peuvent se répertorier comme suit [...] - l'analyse de groupes multiples c'est-à-dire composés de plusieurs raies énergétiques voisines. Cette application ne nécessite pas d'étalonnage préalable. Elle utilise des données physiques des isotopes concernés et des algorithmes de déconvolution spectrale pour extraire le maximum d'informations du seul spectre; celui de l'échantillon inconnu.

Spanish

Save record 10

Record 11 2003-04-09

English

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Scientific Measurements and Analyses
CONT

X-ray Diffraction Method is an accurate, reliable and time proven tool for residual stress analysis. Using Bragg's law of diffraction the value of surface residual stress can be found by measuring the angle at which an X-ray beam diffracts from the surface of an analyzed component. This measurement method is absolute : i. e. it does not require calibration on samples of known stress levels.

CONT

Qualitative and quantitative phase analysis, grain size and micro-stresses determination, macro-stresses measurement using X-ray diffraction method.

Key term(s)
  • X-rays diffraction method
  • X rays diffraction method
  • X ray diffraction method

French

Domaine(s)
  • Physique radiologique et applications
  • Mesures et analyse (Sciences)
CONT

Deux méthodes de diffraction sont les plus utilisées pour déterminer les contraintes résiduelles à la surface des matériaux cristallins : la méthode par diffraction de neutrons et la méthode par diffraction des rayons X, qui fut la première proposée par Lester et Abon au siècle dernier (1925) [...] Le principe est fondé sur la mesure des variations des distances inter-atomiques liées directement à la présence de contraintes résiduelles. L'introduction d'un champ de contraintes résiduelles va se traduire par une déformation du réseau cristallin. En utilisant les plans cristallins comme jauges de déformation, la diffractométrie permet de déterminer de manière non destructive les contraintes en surface dans les matériaux cristallins uniquement [...]

Key term(s)
  • méthode d'analyse par diffraction des rayons X
  • méthode d'analyse par diffraction des rayon-X
  • méthode par diffraction des rayons-X

Spanish

Save record 11

Record 12 2002-11-13

English

Subject field(s)
  • Range Measurements (Telecommunications)
  • Orbital Stations
CONT

The experience of calibration/validation operations(Cal/Val) during the T/P mission has demonstrated the need to develop sites and ground experiments to control the instrumental drifts, which can occur on space altimeter equipment in-situ and along time.... First of all, precise orbit validations, with the development and the systematic use of a short arc orbit determination method based on laser telemetry data from a regional network...

French

Domaine(s)
  • Mesures à distance (Télécommunications)
  • Stations orbitales

Spanish

Save record 12

Record 13 2002-07-29

English

Subject field(s)
  • Ecology (General)
  • Environmental Studies and Analyses
  • Hydrology and Hydrography
CONT

The "wetted perimeter method" will be used for determination of minimum flows. This assumes that trout carrying capacity of the stream is proportional to food production, which in turn is proportional to the wetted perimeter of riffle and other food producing areas. The method requires 3 calibration flows(low, middle and high) in order to describe the relationship between wetted perimeter and discharge.

CONT

The wetted perimeter method was selected ... to establish instream flow protection levels. ... The wetted perimeter method uses field measurements or hydraulic modeling to determine how the wetted perimeter of a study stream changes with flow. Wetted perimeter generally increases rapidly with flow for flows less than some amount, and then increases less rapidly for higher flows. Wetted perimeter is plotted versus flow, and the flow value at the change in slope of the curve (inflection point) is assumed to be the amount of flow needed to protect the biota.

OBS

"Wetted perimeter" refers to the narrowest wetted bottom of the stream cross-section that is estimated to minimally protect all habitat needs ...

French

Domaine(s)
  • Écologie (Généralités)
  • Études et analyses environnementales
  • Hydrologie et hydrographie
DEF

Méthode hydraulique fondée sur l'hypothèse d'une corrélation entre le périmètre mouillé (longueur du fond et des berges en contact avec l'eau dans une section en travers) et l'habitat disponible des poissons [...]

OBS

Ainsi le débit réservé à maintenir à l'aval d'un barrage ne peut plus être ramené à un simple besoin de salubrité ou un débit d'étiage calculé statistiquement supposé être représentatif d'un débit «naturel» reconstitué. Définir un débit minimum à maintenir en rivière implique de faire appel à des notions plus complexes comme les caractéristiques, dans le temps (régime) et dans l'espace, de la lame d'eau et du périmètre mouillé que l'on veut maintenir dans un lit mineur (souvent mal défini au sein du lit majeur), avec comme critère de sauvegarder les espèces animales ou végétales inféodées à la section aménagée (invertébrés du lit de la rivière, végétation des zones riveraines liées à la nappe alluviale).

Spanish

Save record 13

Record 14 2001-05-07

English

Subject field(s)
  • Strength of Materials
  • Engineering Tests and Reliability
  • Joints and Connections (Construction)
CONT

Seam Testing Methods... There are number of procedures available which have applicability on different geomembranes... the ultrasonic impedance plane method works on the principle of acoustic impedance. A continuous wave of 160 to 185 kHz is sent through the seamed liner and a characteristic dot pattern is displayed on a CRT screen. Calibration of the dot pattern is required to signify a good seam; otherwise, it is not. The method has potential for all types of geomembranes but still needs additional development work.

French

Domaine(s)
  • Résistance des matériaux
  • Fiabilité, contrôle et essais (Ingénierie)
  • Joints et assemblages (Construction)

Spanish

Save record 14

Record 15 2000-06-06

English

Subject field(s)
  • Analytical Chemistry
  • Biomass Energy
  • Radiological Physics (Theory and Application)
CONT

Near infrared reflectance spectroscopy(NIRS) is an accurate, precise, and rapid alternative to wet chemistry procedures for determining concentrations of major classes of chemical compounds in organic materials, such as plant foliage. The method utilizes reflectance signals resulting from bending and stretching vibrations in molecular bonds between carbon, nitrogen, hydrogen, and oxygen. Calibration is required to correlate the spectral response of each sample at individual wavelengths to known chemical concentrations from laboratory analyses.

French

Domaine(s)
  • Chimie analytique
  • Énergie de la biomasse
  • Physique radiologique et applications
CONT

Spectrométrie dans le proche infrarouge (NIRS). C'est actuellement la plus performante des méthodes de prédiction pour mesurer la digestibilité de la matière organique qui permet d'apprécier la valeur énergétique d'un fourrage. Lorsqu'on soumet un ensemble de molécules à un rayonnement lumineux infrarouge (longueurs d'ondes comprises entre 780 et 2500 nm), une partie du rayonnement est absorbée, une autre réfléchie. Les longueurs d'ondes absorbées sont spécifiques à chaque constituant et le degré d'absorption proportionnel à sa concentration. Le spectromètre indique ainsi le spectre réfléchi et permet d'en déduire le spectre d'absorption. C'est une méthode de mesure indirecte. Le spectre d'absorption permet de caractériser un produit exactement comme une empreinte digitale permet d'identifier un criminel par comparaison de «l'empreinte» observée avec une banque de données.

Spanish

Save record 15

Record 16 1999-06-15

English

Subject field(s)
  • Atmospheric Physics
  • Atmospheric, Climatic and Meteorological Phenomena
CONT

... the Friehe-Grossman Method... depends upon the accurate calibration and operation of the thermoelectric dewpoint instrument on the aircraft. The method requires that each level leg be independently calibrated. The calibration coefficients are checked for altitude(pressure and/or temperature) dependence. In the case of both IFC-1 and-5 the calibration coefficients were averaged for all legs in the well-mixed layer for a given mission since little altitude dependence was noted for the slope of the calibration curve(which is important to the estimation of the moisture flux).

French

Domaine(s)
  • Physique de l'atmosphère
  • Phénomènes météorologiques, climatiques et atmosphériques
CONT

Une des caractéristiques du climat de l'océan Indien est la mousson. Ce phénomène s'accompagne d'une convection importante, qui présente une forte variabilité à courte échelle de temps (de l'ordre de la journée). Ces variations conditionnent, dans une large mesure, la distribution des variables climatiques tropicales, telles que les précipitations, les flux d'humidité et d'énergie, les vents.

Spanish

Save record 16

Record 17 1998-07-13

English

Subject field(s)
  • Metrology and Units of Measure
OBS

reference material(RM) : Material or substance one or more of whose property values are sufficiently homogeneous and well established to be used for the calibration of an apparatus, the assessment of a measurement method, or for assigning values to materials.

French

Domaine(s)
  • Unités de mesure et métrologie
OBS

matériau de référence (MR) : Matériau ou substance dont une (ou plusieurs) valeur(s) de la (des) propriété(s) est (sont) suffisamment homogène(s) et bien définie(s) pour permettre de l'utiliser pour l'étalonnage d'un appareil, l'évaluation d'une méthode de mesurage ou l'attribution de valeurs aux matériaux.

Spanish

Save record 17

Record 18 1998-01-27

English

Subject field(s)
  • International Bodies and Committees
OBS

... is the technical division of the University of Pennsylvania Museum. When it was established in 1961, it was one of only two organizations worldwide that set as its research goal the development and application of modern scientific techniques to the solution of archaeological problems. MASCA built its reputation through contributions to major improvements in the radiocarbon dating method, including the development of the first calibration curves based on tree-ring dates.

French

Domaine(s)
  • Organismes et comités internationaux

Spanish

Save record 18

Record 19 1995-02-21

English

Subject field(s)
  • Scientific Instruments
  • Oil Refining
  • Petroleum Technology - Equipment
CONT

[Petroleum products. Determination of carbon residue. Ramsbottom method.... Apparatus. ]... Thermocouple. At least once every 50 h of use of the control bulb, calibrate the thermocouple in the control bulb against a standard thermocouple. NOTE-In use at the high temperature of the test, iron-constantan thermocouples oxidize and their calibration curves change.

French

Domaine(s)
  • Instruments scientifiques
  • Raffinage du pétrole
  • Appareillage (Technologie pétrolière)
CONT

[Produits pétroliers. Détermination du carbone résiduel. Méthode «Ramsbottom». [...] Appareillage.] Thermocouple. Étalonner le thermocouple dans l'ampoule de contrôle avec un thermocouple étalon, au moins une fois toutes les 50 h d'utilisation de l'ampoule de contrôle. NOTE - Les thermocouples en fer-constantan qui sont utilisés aux hautes températures de l'essai s'oxydent, et leur courbe d'étalonnage varie.

CONT

[Produits pétroliers. Détermination du résidu «Ramsbottom».] Appareillage. [...] Pyromètre à thermocouple fer-constantan, donnant la température à 1 °C près, logé centralement et disposé pour mesurer la température du four.

Spanish

Save record 19

Record 20 - external organization data 1994-11-14

English

Subject field(s)
  • Engineering Tests and Reliability
  • Radiological Physics (Theory and Application)
  • Compartment - Canadian Nuclear Safety Commission
CONT

Leak Test Measuring Certificate Requirements. A measuring certificate shall contain the following information : a) measurer(name, address, and telephone number) ;b) licensee... c) cross reference to leak test sampling certificate; d) brief description of measuring method; e) date of last calibration and verification check of measuring equipment; f) local radiation background as indicated by measuring equipment; g) sample measurement value; h) calculation and evaluation of sample measurement... i) test evaluation... j) measuring date; k) signature of measurer.

French

Domaine(s)
  • Fiabilité, contrôle et essais (Ingénierie)
  • Physique radiologique et applications
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le certificat de mesure doit comporter les renseignements suivants : a) le nom, l'adresse et le numéro de téléphone de l'échantillonneur; b) le nom, l'adresse [...] du titulaire de permis, ainsi que la personne-ressource; c) la désignation de la source scellée (marque, modèle, isotope, numéro de série de la source scellée [...]); d) une brève description de la méthode d'échantillonnage; e) la désignation du contenant de l'échantillon [...] g) la date de l'échantillonnage; g) la signature de l'échantillonneur.

Spanish

Save record 20

Record 21 1993-11-17

English

Subject field(s)
  • Nuclear Medicine
CONT

Two methods for the measurements of osseous change detected by digital substraction radiography have been evaluated... The radiographic image method uses a calibration wedge on each of the two films. The mean gray value of the ROI((region of interest)) on each film is converted into an equivalent thickness of bone by matching the ROI mean gray value to a gray value along the wedge.(In J Periodontal Res Sep 1990, 25(5) p268-75, cited in data bases.)

French

Domaine(s)
  • Médecine nucléaire
OBS

Renseignement obtenu d'une technicienne en radiologie.

Spanish

Save record 21

Record 22 1989-11-15

English

Subject field(s)
  • Scientific Instruments
  • Physics of Solids
CONT

Mass spectrometry. The analysis of solid inorganic samples can be made... by vaporization in a Knudsen cell arrangement at very high temperature.... Detection... is by photographic plate; exposures for different lengths of time are recorded sequentially, and the darkening of the lines on the plate is related empirically to quantitative composition by calibration charts. The method is useful for trace analysis....

French

Domaine(s)
  • Instruments scientifiques
  • Physique des solides
OBS

Une cellule de Knudsen est une petite enceinte munie d'un orifice de surface au moins 100 fois plus petit que la surface intérieure de l'enceinte et de diamètre au moins 10 fois inférieur au libre parcours moyen des molécules de gaz contenues.

Spanish

Save record 22

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: