Record 1 2017-06-08

English

Subject field(s)
  • Control Systems (Motor Vehicles)
  • Engineering Tests and Reliability
  • Braking Systems (Motor Vehicles and Bicycles)
  • Wheels and Tires (Motor Vehicles and Bicycles)
DEF

A component responsible for modulating the pressure and therefore the braking force in direct response to control signals received from the controller.

CONT

As soon as a wheel locks during braking, the logic controller sends a signal to the modulator to reduce air pressure in the brake cylinder of that wheel, thus preventing the wheel from locking up.

OBS

modulator: term and definition standardized by ISO.

OBS

modulator: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Dispositifs de commande (Véhicules automobiles)
  • Fiabilité, contrôle et essais (Ingénierie)
  • Freins (Véhicules automobiles et bicyclettes)
  • Roues et pneus (Véhicules automobiles et bicyclettes)
DEF

Élément chargé de moduler la pression et donc la force de freinage en fonction du signal de commande reçu du calculateur.

CONT

Dès que l'une des roues est en condition de blocage pendant la période de freinage, le boîtier électronique commande le modulateur pour réduire la pression d'air dans le cylindre de frein correspondant, évitant ainsi le blocage de la roue.

OBS

modulateur : terme et définition normalisés par l'ISO.

OBS

modulateur : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick

Spanish

Campo(s) temático(s)
  • Sistemas de regulación (Vehículos automotores)
  • Fiabilidad y ensayos (Ingeniería)
  • Frenos (Vehículos automotores y bicicletas)
  • Ruedas y neumáticos (Vehículos automotores y bicicletas)
DEF

Componente responsable de modular la presión y por tanto la fuerza del frenado en respuesta directa a las señales de control recibidas del controlador.

CONT

Cuando una de las ruedas se encuentra en situación de bloqueo durante el frenado, el microprocesador acciona el modulador y reduce la presión de aire en el cilindro correspondiente, evitando que la rueda se bloquee.

Save record 1

Record 2 2014-12-09

English

Subject field(s)
  • Control Instrumentation (Mechanical Components)
  • Electronic Devices
DEF

A potentiometer mounted in or on a modulating motor, which is used to control an external device in response to movements of the motor.

French

Domaine(s)
  • Dispositifs de commande (Composants mécaniques)
  • Dispositifs électroniques
OBS

Le deuxième problème apparaissant rapidement, fut la vitesse excessive du véhicule. Nous avons donc cherché le moyen à mettre en œuvre pour la ralentir, car nous pensions qu'en ralentissant la vitesse du véhicule, nous aurions une meilleure précision sur la distance de déplacement. La première idée venue était de diminuer la tension aux bornes du moteur propulseur, en ajoutant un potentiomètre monté en diviseur de tension. L'un des principaux défauts de ce système est le manque de précision du potentiomètre qui doit être assez gros (puissance > 0,5 Watt) pour supporter le courant important sur le moteur. Ce montage dissipait donc trop d'énergie, pour nous permettre une répétabilité des mesures.

Spanish

Save record 2

Record 3 2014-11-25

English

Subject field(s)
  • Wastewater Treatment
CONT

DEGRÉMONT often construct siphon distribution systems to regulate the distribution of raw water from the various cells and determine the returned sludge intake points, thus modulating the water-sludge supply by remote control without any risk of obstructing the control valves.

French

Domaine(s)
  • Traitement des eaux usées
CONT

Pour le réglage de la distribution d'eau brute des différentes cellules et le choix du point d'injection des boues de retour, DEGRÉMONT met souvent en œuvre un système de répartition par siphons permettant par une régulation à distance et sans aucun risque d'obstruction des vannages de contrôle, de moduler à volonté l'alimentation eau-boues.

Spanish

Save record 3

Record 4 2014-11-25

English

Subject field(s)
  • Pipes and Fittings
  • Wastewater Treatment
CONT

DEGRÉMONT often construct siphon distribution systems to regulate the distribution of raw water from the various cells and determine the returned sludge intake points, thus modulating the water-sludge supply by remote control without any risk of obstructing the control valves.

French

Domaine(s)
  • Tuyauterie et raccords
  • Traitement des eaux usées
CONT

Pour le réglage et la distribution d'eau brute des différentes cellules et le choix du point d'injection des boues de retour, DEGRÉMONT met souvent en œuvre un système de répartition par siphons permettant par une régulation à distance et sans aucun risque d'obstruction des vannages de contrôle, de moduler à volonté l'alimentation eau-boues.

Spanish

Save record 4

Record 5 2014-11-25

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
CONT

DEGREMONT often construct siphon distribution systems to regulate the distribution of raw water from the various cells and determine the returned sludge intake points, thus modulating the water-sludge supply by remote control without any risk of obstructing the control valves.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
CONT

Pour le réglage de la distribution d'eau brute des différentes cellules et le choix du point d'injection des boues de retour, DEGREMONT met souvent en œuvre un système de répartition par siphons permettant par une régulation à distance et sans aucun risque d'obstruction des vannages de contrôle, de moduler à volonté l'alimentation eau-boues.

Spanish

Save record 5

Record 6 2014-11-25

English

Subject field(s)
  • Applications of Automation
  • Equipment and Tools (Water Supply)
  • Wastewater Treatment
CONT

DEGRÉMONT often construct siphon distribution systems to regulate the distribution of raw water from the various cells and determine the returned sludge intake points, thus modulating the water-sludge supply by remote control without any risk of obstructing the control valves.

French

Domaine(s)
  • Automatisation et applications
  • Équipement et outillage (Alimentation en eau)
  • Traitement des eaux usées
CONT

Pour le réglage de la distribution d'eau brute des différentes cellules et le choix du point d'injection des boues de retour, DEGRÉMONT met souvent en œuvre un système de répartition par siphons permettant par une régulation à distance et sans aucun risque d'obstruction des vannages de contrôle, de moduler à volonté l'alimentation eau-boues.

Spanish

Save record 6

Record 7 2011-10-12

English

Subject field(s)
  • Electric Motors
  • Control Instrumentation (Mechanical Components)
DEF

An electric motor, used to drive a valve or damper, which can position the valve or damper anywhere between fully open or fully closed in proportion to changes in the controlled medium.

OBS

Modutrol ... Honeywell trademark

OBS

modulating control : a method of control capable of increasing or decreasing by increments a quantity according to deviation from the required value.

French

Domaine(s)
  • Moteurs électriques
  • Dispositifs de commande (Composants mécaniques)
OBS

régulation modulante : mode de régulation opérant par action de faible amplitude autour de la valeur désirée.

Spanish

Save record 7

Record 8 2011-05-03

English

Subject field(s)
  • Control Instrumentation (Mechanical Components)
DEF

A proportioning controller which automatically positions the device it controls anywhere between its extreme positions in response to changes in the controlled medium.

OBS

modulating control : A method of control capable of increasing or decreasing by increments a quantity according to deviation from the required value.

OBS

modulating controller: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Dispositifs de commande (Composants mécaniques)
CONT

Régulateurs modulants pour chaudières individuelles.

OBS

régulation modulante : Mode de régulation opérant par action de faible amplitude autour de la valeur désirée.

OBS

régulateur modulant : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 8

Record 9 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
CONT

modulating fire. Varying the firing rate as the load varies. This results in longer burner operation because the firing rate is lowered as temperature or pressure builds up toward the cutoff point. It decreases on-off operation and increases the efficiency of the system.

CONT

There are four widely used operating configurations for gas fired appliances: modulating fire, on-off, hi-low, and multi-stage firing. Modulating fire is accomplished by mechanically varying the size of the gas admittance opening of one or more special "modulating" gas valves. With the gas valve completely open the boiler fires at it’s full fire rate. The unit is said to be at "full turndown" when it fires at it’s lowest firing rate. The "turndown ratio" is the ratio of full fire rate to full turndown firing rate and is a function of boiler design. A turn down ratio of 5:1 would indicate that a boiler is capable of a full turndown firing rate of 20% (5:1 (100% fire : 20% fire).

OBS

modulating control : a method of control capable of increasing or decreasing by increments a quantity according to deviation from the required value.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Les brûleurs de gaz à air soufflé Piroil sont fournis sous forme monobloc, précâblés et prêts pour le fonctionnement. Construits pour une puissance thermique de 30.000 à 2.5000.000 Kcal/h dans les versions suivantes: une allure, deux allures, progressifs [...] Fonctionnement. Le cycle de travail prévoit au démarrage une période de prébalayage de la chambre de combustion avec le clapet d'air complètement ouvert, et obtenue à l'aide du servomoteur. Durant cette période l'éléctrovanne est fermée. À la fin de cette phase, avec le clapet d'air et le manchon gaz positionnés à une valeur minimale par le servomoteur, l'électrovanne gaz est excitée et le transformateur pourvoit à l'allumage du gaz au débit minimum. À ce moment, après avoir obtenu le consentement de présence de flamme par l'électrode d'ionisation, la boîte de contrôle met en marche le servomoteur air-gaz qui porte le brûleur, progressivement, dans un délai préétabli, à sa puissance maximale. Le brûleur reste en ces conditions de travail jusqu'à atteindre la température maximale, après cela, toujours thermostatiquement, à l'aide du servomoteur, on stabilise la puissance à un régime minimal, jusqu'à la demande de chaleur par la chaudière, qui peut être réétablie avec une modulation successive, sans pourtant interrompre complètement le fonctionnement.

OBS

régulation modulante : mode de régulation opérant par action de faible amplitude autour de la valeur désirée.

Spanish

Save record 9

Record 10 1991-05-27

English

Subject field(s)
  • Types of Industrial Operations
DEF

A controller which can use one or more microprocessors to accomplish the control function on several modulating control loops.

French

Domaine(s)
  • Types d'exploitation industrielle

Spanish

Save record 10

Record 11 1990-06-12

English

Subject field(s)
  • Burners and Steamfitting
CONT

Return Flow Pressure Atomizing Oil Burner. This burner is a modification of the pressure atomizing burner; it is also called a modulating pressure atomizer. It has the advantage of wide load range for any given atomizer,... this wide range is accomplished through a return flow nozzle which has an atomizing swirl chamber just ahead of the orifice. Good atomization throughout the load range is attained by maintaining a high rate of oil flow and high pressure drop through the swirl chamber. The excess oil above the load demand is returned from the swirl chamber to the oil storage tank or to the suction of the oil pump. Control of burning rate is effected by varying the oil pressure in both the oil inlet and oil return lines. Except for the atomizer, load range, and method of control, the information given for the straight pressure atomizing burner applies to this burner.

OBS

Both terms [mechanical atomizing and pressure atomizing] designate atomization of the oil by forcing it at high pressure through a suitable stationary atomizer.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Pulvérisation mécanique à retour. Dans le but d'obtenir une plage suffisante, le pulvérisateur mécanique est complété d'un circuit de retour qui ramène au réservoir une partie du combustible prélevé dans le pulvérisateur même (...).

Spanish

Save record 11

Record 12 1987-05-04

English

Subject field(s)
  • Aeroindustry
CONT

The [freeze prevention] system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air. The system taps into the APU bleed air supply duct before the check valve at the elbow under the catwalk and air is distributed by auxiliary ducts to a muffler under the flow control valve of each pack and to a single spray bar upstream of the left diverter valve. A temperature control valve in the ducting regulates the volume of bleed air to be used.

French

Domaine(s)
  • Constructions aéronautiques
CONT

Ce silencieux est fixé par vis sur la prise d'air du refroidisseur d'huile. Il est constitué d'une cuvette et d'un couvercle percés de plusieurs orifices qui permettent le passage de l'air de refroidissement. L'insonorisation est assurée par de la laine de verre qui est placée à l'intérieur de la cuvette.

OBS

silencieux : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 12

Record 13 1987-02-10

English

Subject field(s)
  • Aircraft Systems
CONT

The freeze prevention system maintains the air-conditioning system in a freeze free operating condition in cold weather with extremely high humidity on the ground. The system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air.

OBS

in water separator.

French

Domaine(s)
  • Circuits des aéronefs
OBS

système antigivrage : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 13

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: