Record 1 2024-11-19

English

Subject field(s)
  • Radiography (Medicine)
DEF

A technique in which x-ray absorption is quantified by the assignment of a number to the amount of x-rays reaching the detector; the information is entered into a computer and manipulated to produce an optimal image.

French

Domaine(s)
  • Radiographie (Médecine)
CONT

La radiographie numérique consiste en la numérisation des images produites par remplacement du récepteur «classique» de la radiographie conventionnelle autrement dit la cassette «écran-film» par un récepteur spécifique du système numérique.

Spanish

Campo(s) temático(s)
  • Radiografía (Medicina)
CONT

En la radiografía digital directa, los rayos-x son capturados por una placa de circuitos sensibles a la radiación que genera una imagen digital y la envía al computador en la forma de señales eléctricas; la imagen se procesa y llega a los profesionales de salud, que la pueden almacenar o imprimir.

Save record 1

Record 2 2024-09-27

English

Subject field(s)
  • Nuclear Science and Technology
  • CBRNE Weapons
DEF

The measurement of radiation activity caused by background radiation and/or other sources that are not under consideration.

OBS

[Background count] is expressed as a number that refers to the quantity of disintegrations detected by a detector.

OBS

background count: designation and definition standardized by NATO.

French

Domaine(s)
  • Sciences et techniques nucléaires
  • Armes CBRNE
DEF

Mesure de l'activité radioactive causée par la radioactivité naturelle et/ou d'autres sources parasites.

OBS

[Le comptage du bruit de fond radiologique] se traduit par un nombre qui correspond à la quantité de désintégrations détectées par un détecteur.

OBS

comptage du bruit de fond radiologique : désignation et définition normalisées par l'OTAN.

Spanish

Campo(s) temático(s)
  • Ciencia y tecnología nucleares
  • Armas QBRNE
DEF

Indicación, que aparece sobre un detector de radiación y que no es debida al efecto que se desea detectar.

OBS

En relación con la protección de la salud, este fondo está formado por radiaciones producidas por la radiactividad natural y por los rayos cósmicos.

Save record 2

Record 3 2016-06-27

English

Subject field(s)
  • Scientific Instruments
  • Analytical Chemistry
DEF

A detector in which hydrocarbons are burned in a hydrogen-air flame and the electrical current caused by the resulting ions is measured between two electrodes. [Definition standardized by ISO in 2014.]

DEF

A hydrogen-air diffusion flame detector that produces a signal nominally proportional to the mass-flow rate of hydrocarbons entering the flame per unit of time-generally assumed responsive to the number of carbon atoms entering the flame. [Definition officially approved by ICAO. ]

OBS

The flame ionization detector is used in gas chromatography mainly to detect hydrocarbon compounds.

OBS

flame ionization detector; FID: term and abbreviation standardized by ISO in 2014.

OBS

flame ionization detector; FI-detector: terms extracted from the "Disarmament and Peace Keeping" glossary with the permission of the United Nations Office at Geneva.

OBS

flame ionization detector; FID: term and abbreviation officially approved by the International Civil Aviation Organization (ICAO).

Key term(s)
  • flame ionisation detector

French

Domaine(s)
  • Instruments scientifiques
  • Chimie analytique
DEF

Détecteur dans lequel les ions résultant de la combustion des hydrocarbures dans une flamme air/hydrogène sont mesurés électriquement entre deux électrodes.

OBS

Le détecteur à ionisation de flamme est utilisé en chromatographie en phase gazeuse pour détecter plus particulièrement les composés hydrocarbonés.

OBS

détecteur à ionisation de flamme; FID : terme, abréviation et définition normalisés par l'ISO en 2014.

OBS

détecteur à ionisation de flamme; détecteur FI : termes tirés du lexique «Désarmement et Maintien de la Paix» avec l'autorisation de l'Office des Nations Unies à Genève.

OBS

détecteur à ionisation de flamme : terme uniformisé par l'Organisation de l'aviation civile internationale (OACI).

Spanish

Campo(s) temático(s)
  • Instrumentos científicos
  • Química analítica
DEF

Dispositivo en el que el cambio medido de la conductividad de una llama patrón (generalmente de hidrógeno) debido a la introducción de otro gas o vapor, se utiliza para detectar dicho gas o vapor.

CONT

El detector de ionización de llama (Abreviadamente DILL) es otro de los detectores más populares y sensibles. Su detectabilidad puede ser unas mil veces más baja que el de conductividad térmica.

OBS

detector de ionización de la llama; detector de la ionización de la llama; FID: término y abreviatura aceptados oficialmente por la Organización de Aviación Civil Internacional (OACI).

Save record 3

Record 4 2015-05-25

English

Subject field(s)
  • Scientific Instruments
  • Atomic Physics
CONT

The liquid scintillator neutrino detector(LSND) was a scintillation counter at Los Alamos National Laboratory that measured the number of neutrinos being produced by an accelerator neutrino source.

French

Domaine(s)
  • Instruments scientifiques
  • Physique atomique

Spanish

Save record 4

Record 5 2015-02-20

English

Subject field(s)
  • Radar, Radio Guidance and Goniometry
CONT

Several automatic decision-making criteria have been used to determine the beginning, end, and center of the target. Two principal types are the sliding window and the sequential observer. The sliding-window detector... stores the number of radar returns at target range within each prescribed incremental range-resolution element during the past N azimuthal trials. If the number of returns exceeds a predesignated value... the target is declared to be detected.

French

Domaine(s)
  • Radar, radioguidage et radiogoniométrie
CONT

Pour réaliser le traitement de la vidéo d'un radar à antenne tournante, le test est appliqué aux signaux recueillis dans une fenêtre glissante [...] Cette fenêtre est très étroite en distance et elle s'étend en azimut sur une portion de faisceau d'antenne. Sa forme est adaptée à la non stationnarité du Clutter. La distribution varie rapidement avec la distance; par contre, elle varie lentement entre deux récurrences successives (à même distance) à cause de la corrélation spatiale due au faisceau d'antenne.

Spanish

Save record 5

Record 6 2011-12-22

English

Subject field(s)
  • Atomic Physics
  • Analytical Chemistry
  • Nuclear Physics
CONT

A number of devices are available to assay Contact Handled-Transuranic(CH-TRU) for fissile material. One assay technique employs a pulsed fast-neutron source of 108 neutron/second to provide interrogation neutrons that upon thermalization produce fissions in any fissile material. The fission neutrons, counted using3He detector packs, are separated from the interrogation neutrons by their longer die-away time.

French

Domaine(s)
  • Physique atomique
  • Chimie analytique
  • Physique nucléaire
CONT

La quantification non destructive de la masse de noyaux lourds au moyen de la mesure neutronique active repose sur la stimulation de la réaction de fission et la mesure des neutrons qui en découlent. Cela suppose une source de particules interrogatrices (source isotopique, générateur de neutrons, accélérateur d’électrons...), une enceinte de thermalisation destinée à ralentir et à maintenir les neutrons interrogateurs à des énergies où les sections efficaces de fission associées aux isotopes recherchés sont optimales et, enfin, un dispositif de détection pour la mesure des neutrons. Le signal neutronique de fission est directement lié à la masse de matière qui a fissionné. Sa connaissance permet, étalonnage à l’appui, de quantifier cette masse.

Spanish

Save record 6

Record 7 2011-01-10

English

Subject field(s)
  • Radiological Physics (Theory and Application)
DEF

The time it takes for determining the number of pulses supplied by a radiation detector.

French

Domaine(s)
  • Physique radiologique et applications
DEF

Temps nécessaire pour déterminer le nombre d’impulsions livrées par un détecteur de rayonnement.

Spanish

Save record 7

Record 8 2010-05-19

English

Subject field(s)
  • Radiography (Medicine)
CONT

The detector is comprised of a pair of x-ray intensifying screen/linear photodiode arrays, aligned one behind the other. Energy discrimination is achieved by employing a low atomic number phosphor in the front screen and a high atomic number phosphor in the back screen.

French

Domaine(s)
  • Radiographie (Médecine)
OBS

Les écrans renforçateurs sont habituellement utilisés par paires, un écran de chaque côté du film.

Spanish

Save record 8

Record 9 2010-05-19

English

Subject field(s)
  • Radiography (Medicine)
CONT

The detector is comprised of a pair of x-ray intensifying screen/linear photodiode arrays, aligned one behind the other. Energy discrimination is achieved by employing a low atomic number phosphor in the front screen and a high atomic number phosphor in the back screen.

French

Domaine(s)
  • Radiographie (Médecine)
OBS

Les écrans renforçateurs sont habituellement utilisés par paires, un écran de chaque côté du film.

Spanish

Save record 9

Record 10 2009-09-09

English

Subject field(s)
  • Scientific Measurements and Analyses
  • Nuclear Fission Reactors
CONT

The intrinsic efficiency is the ratio of counts detected to the number of photons or particles incident on the detector and is a measure of how many photons or particles result in a gross count.

OBS

Some radiation is not energetic enough and does not reach the detector because it is attenuated or scattered before it can interact in the detector.

French

Domaine(s)
  • Mesures et analyse (Sciences)
  • Réacteurs nucléaires de fission
CONT

L'efficacité intrinsèque correspond au rapport du nombre d'impulsions mesurées dans [un] détecteur sur le nombre de particules pénétrant dans le détecteur [...]

Spanish

Save record 10

Record 11 2008-11-18

English

Subject field(s)
  • Gas Industry
  • Radiological Physics (Theory and Application)
CONT

The radiation is measured by measuring the number of pulses per time unit coming from the tube, which is proportional to the intensity of the radiation to be measured. The quenching gas in the radiation detector tubes is quenching after the elapse of a certain period of time the ionic current. This time is called the dead time of the G-M tube, during which the tube is unable to react to a possibly, arriving new quantum of radiation.

French

Domaine(s)
  • Industrie du gaz
  • Physique radiologique et applications
DEF

Élément constitutif du mélange gazeux destiné au remplissage d'un tube compteur de Geiger-Müller, qui accélère l'auto-excitation de la décharge.

Spanish

Save record 11

Record 12 2007-01-31

English

Subject field(s)
  • Radar, Radio Guidance and Goniometry
  • Spacecraft
  • Remote Sensing
CONT

[The] push-broom scanner [is a] type of imaging system... commonly used in optical remote sensing satellites such as SPOT. The imaging system has a linear detector array(usually of the CCD type) consisting of a number of detector elements(6000 elements in SPOT HRV). Each detector element projects an "instantaneous field of view(IFOV) "on the ground. The signal recorded by a detector element is proportional to the total radiation collected within its IFOV. At any instant, a row of pixels are formed. As the detector array flies along its track, the row of pixels sweeps along to generate a two-dimensional image.

OBS

linear detector array: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

French

Domaine(s)
  • Radar, radioguidage et radiogoniométrie
  • Engins spatiaux
  • Télédétection
CONT

La mission d'observation est réalisée par un instrument à barrette CCD [charged-coupled device] de type «push-broom» avec une visée au nadir : sous l'effet du défilement du satellite sur son orbite, une barrette de détecteurs carrés disposés en ligne acquiert successivement les différentes lignes permettant de reconstituer une image. La taille de chaque détecteur élémentaire et la période d'échantillonnage sont ajustées de telle manière qu'en une période d'échantillonnage le point subsatellite se déplace de la projection au sol d'un détecteur au nadir.

OBS

barrette de détecteurs : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

PHR

Capteur à barrette de détecteurs.

Spanish

Campo(s) temático(s)
  • Guía radárica, radioguía y radiogoniometría
  • Naves espaciales
  • Teledetección
Save record 12

Record 13 2006-06-14

English

Subject field(s)
  • Remote Sensing
CONT

Preprocessing is an important and diverse set of image preparation programs that act to offset problems with the band data and recalculate DN [Digital Number] values that minimize these problems. Among the programs that optimize these values are atmospheric correction(affecting the DNs of surface materials because of radiance from the atmosphere itself, involving attenuation and scattering) ;Sun illumination geometry; surface-induced geometric distortions; spacecraft velocity and attitude variations(roll, pitch, and yaw) ;effects of Earth rotation, elevation, curvature(including skew effects), abnormalities of instrument performance(irregularities of detector response and scan mode such as variations in mirror oscillations) ;loss of specific scan lines(requires destriping), and others. Once performed on the raw data, these adjustments require appropriate radiometric and geometric corrections.

OBS

preprocessing: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

French

Domaine(s)
  • Télédétection
CONT

La première étape de prétraitement des données SAR correspond à la transformation des données 16 bits en données 8 bits et ce, afin de faciliter la manipulation ainsi que la combinaison avec les autres données optiques qui sont, généralement, sur 8 bits. La deuxième étape consiste à réduire le châtoiement inhérent aux images SAR [radar à synthèse d'ouverture] [...] La troisième étape comprend le prétraitement des données TM [Thematic Mapper] de Lansat dont le but vise essentiellement l'amélioration de la qualité des images. Cette étape est effectuée en trois phases : la superposition géométrique, le géocodage des images optiques comparées à une image SAR disponible de type GEC [Geocoded Ellipsoid Corrected] et, enfin, le rééchantillonnage des pixels à une résolution de 25 m.

OBS

prétraitement : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

Spanish

Save record 13

Record 14 2004-03-18

English

Subject field(s)
  • Analytical Chemistry
CONT

Separation of spectral and non-spectral interferences by on-line high performance ion chromatography inductively coupled plasma sector field mass spectrometry (HPIC-ICP-SFMS) for accurate determination of234U,235U,238U and232Th in industrial ores.

CONT

Determination of trace elements in human milk by inductively coupled plasma sector field mass spectrometry (ICP-SFMS).

CONT

Indiana University Laboratory for Spectrochemistry. Plasma Source Mass Spectrometry. "Single-Crystal Scintillator-Based Array Detector for Sector-Field Mass Spectrometry, "[by] David A. Solyom. Beginning with the use of photographic plates in the first quarter of this century, array detectors have had a long history of usage in mass-spectrometric analysis. Array detectors are position-sensitive devices capable of independently measuring ion signals that are incident at different locations on the detector's face. Currently popular among the different types of array detectors available for mass spectrometry are microchannel-plate(s)(MCP) coupled with a phosphor.... The electrons emitted from the rear of the MCP strike the phosphor being held in close proximity(1mm) to the MCP. The phosphor screen is sensitive to the incident electrons and will emit photons in response. The number of emitted photons is proportional to the number of incident electrons and the location on the phosphor from which the photons are emitted coincides with the location of the incident electrons. The photons from the phosphor can then be converted into a proportional electronic signal by an imaging device such as a CCD or CID detector array.

French

Domaine(s)
  • Chimie analytique
CONT

spectrométrie de masse à secteurs à plasma induit (ICP-SFMS).

OBS

Il existe plusieurs traductions du terme «inductively coupled plasma (ICP)» : le plus proche de la description de la technique est «plasma induit par un courant de haute fréquence», le plus simple est «torche à plasma»; pour décrire un «sector field mass spectrometer» nous parlons de «spectromètre de masse à secteur magnétique» ou, plus brièvement, de «spectromètre de masse magnétique». L'équivalent français de ICP-SFMS serait donc «torche à plasma couplée à un spectromètre de masse magnétique» (version courte) ou «plasma induit par un courant de haute fréquence associé à un spectromètre de masse à secteur magnétique» (version longue). [Source : Guy Bouchoux, Secrétaire, Société française de spectrométrie de masse, École Polytechnique, DCMR, Palaiseau (France)]

Spanish

Save record 14

Record 15 2001-05-15

English

Subject field(s)
  • Scientific Research Equipment
  • Printed Circuits and Microelectronics
CONT

The typical particle counter for metering the amount of particulate matter in clean work station air is an optical assembly. Air is drawn into and through the optical subassembly of the particle counter until a pre-set volume of air has been seen. The particles which are drawn into this optical subassembly cause a pulse of light to be scattered for each particle present. The light pulse is sensed by a detector which converts the pulse to an electrical voltage signal. Each signal is cumulatively counted, for the pre-set volume of air. From the amplitude of the voltage, the size of each particle can be determined. All particle counters consist of three basic subassemblies. These are the optical subassembly which "sees" the particles, a pump subassembly which draws the air stream into and through the optical subassembly, and an electronic subassembly for converting each particle size/unit number to an electrical signal. Also available, usually as an option, is some form of printer.

French

Domaine(s)
  • Matériel et équipement (Recherche scientifique)
  • Circuits imprimés et micro-électronique

Spanish

Save record 15

Record 16 1998-05-20

English

Subject field(s)
  • Analytical Chemistry
DEF

[a detector] responding to a group of compounds or a number of species.

CONT

Detectors which are specially designed to give a signal only when members of particular groups of solutes pass through are referred to as selective detectors. In practice nearly all detectors are selective in one way or another ... Typical of the selective detectors are those intended to detect only compounds containing a particular element or family of elements.

OBS

As opposed to "universal detector" (see record).

PHR

elemental selective detector

Key term(s)
  • specific detector

French

Domaine(s)
  • Chimie analytique
DEF

[...] appareil ne donnant un signal (une réponse) que pour une ou plusieurs familles de produits bien déterminés [...]

CONT

Utilisation des détecteurs sélectifs. [...] certains détecteurs ne répondent qu'à des substances de familles données ou ont une sensibilité considérable pour celles-là. On peut utiliser ce fait pour faciliter l'identification des pics en montant en parallèle un détecteur universel et un détecteur sélectif [...]

Spanish

Save record 16

Record 17 1997-11-26

English

Subject field(s)
  • Chemistry
DEF

The ration of the number of particles or photons detected to the number of similar particles or photons which have struck the envelope limiting the sensitive volume of a radiation detector.

French

Domaine(s)
  • Chimie
DEF

[...] rapport entre le nombre de particules ou de photons détectés et le nombre de particules ou de photons similaires qui ont frappé l'enveloppe qui limite le volume sensible du détecteur à rayonnement.

Spanish

Save record 17

Record 18 1996-05-13

English

Subject field(s)
  • Analytical Chemistry
CONT

... the scanning-wavelength detector... has many advantages :... It offers a real-time spectrum from 190 to 600 nm that can be obtained in as little as 0. 01 s for each solute as it elutes.... Spectra are available for visual presentation as three-dimensional chromatograms of time vs. wavelength vs. absorbance.... When diode arrays are used as the detector, it is possible later to extract data at other wavelengths from the memory.... Some instruments can be configured to monitor simultaneously a number of wavelength intervals with bandwidths ranging between 4 and 400 nm. This permits the integration of all signals between two preset wavelengths.... With simultaneous absorbance detection at several wavelengths, the presence of coeluting peaks is diagnosed from the shifting of retention times as a function of detection wavelength.... Peak purity can be determined by taking a spectrum at the front and at the rear of a peak.

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 18

Record 19 1989-09-19

English

Subject field(s)
  • Aeroindustry
  • Radar, Radio Guidance and Goniometry
CONT

The AN/APR-39(V) 1 radar signal detector has been in production for some 20 months and is currently operational on a number of US Air Force helicopters and light aircraft.

French

Domaine(s)
  • Constructions aéronautiques
  • Radar, radioguidage et radiogoniométrie
CONT

Cela fait une vingtaine de mois qu'est fabriqué le détecteur de signaux radar AN/APR-39(V)1. Il est en service sur un certain nombre d'hélicoptères et d'avions légers de l'US Air Force.

Spanish

Save record 19

Record 20 1986-02-25

English

Subject field(s)
  • Scientific Instruments
  • Scientific Measurements and Analyses
  • Thermal Insulation
DEF

... an instrument which makes a number of successive radiometric measurements along a line in one direction. This may be accomplished by means of a mechanism scanning the radiation along a line, by a number of radiometric detector elements in a line, or by a combination of the two. [They] can be either "imaging" or "non-imaging".

French

Domaine(s)
  • Instruments scientifiques
  • Mesures et analyse (Sciences)
  • Isolation thermique

Spanish

Save record 20

Record 21 1982-03-12

English

Subject field(s)
  • Road Traffic
  • Applications of Electronics
OBS

This gives a continuous response when stationary or moving vehicles are within a selected area of carriageway. It maintains that response indefinitely so long as the selected area is occupied. The detector may or may not give an output which varies with the number of vehicles within the area of detection. This type of detector is also called an occupancy detector.

Key term(s)
  • continuous-presence detector

French

Domaine(s)
  • Circulation routière
  • Applications de l'électronique
Key term(s)
  • détecteur de présence continue

Spanish

Save record 21

Record 22 1977-11-09

English

Subject field(s)
  • Geophysics
  • Scientific Measurements and Analyses
OBS

The transmitter loop is a large rectangle, several thousand feet to the side. A long wire might also be used. The detector consists of two mutually perpendicular loops, one horizontal and one vertical, connected effectively in opposition through a transformer to amplifier and headphones. The vertical coil, with a fixed number of turns, is shunted by a capacitance to give parallel resonance at the source frequency and is connected through a reversing switch to the transformer primary. The horizontal coil has multiple taps for a variable inductance. The coils are about two feet in diameter and are mounted on a vertical post.

French

Domaine(s)
  • Géophysique
  • Mesures et analyse (Sciences)
OBS

[Méthode électromagnétique où la source émettrice est fixe et le récepteur mobile. Cette méthode] fait l'emploi d'un grand cadre rectangulaire disposé horizontalement sur le sol qui sert de source émettrice du champ primaire. On suppose que l'axe majeur de l'ellipse de polarisation qui représente la composante réelle du champ résultant est quasi vertical tandis que l'axe mineur qui représente la composante imaginaire est horizontal. Le récepteur est constitué de deux petits cadres rectangulaires qui sont mutuellement perpendiculaires. Le cadre horizontal mesure la composante réelle et le cadre vertical la composante imaginaire. L'axe majeur et l'axe mineur de l'ellipse de polarisation sont déphasés de 90 ° et ce sont les composantes du champ représentées par ces deux axes qui sont comparées.

Spanish

Save record 22

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: