TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

PIPING VALVE SYSTEM [13 records]

Record 1 2017-05-31

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Taps and Plumbing Accessories
  • Fixed Rescue Facilities (fire)
CONT

One characteristic of a dry-pipe system is a delay in time between the opening of a sprinkler and the discharge of water, which may allow the fire to spread and more sprinklers to open. The delay is due to the time required to exhaust the air from the sprinkler piping. The difficulty may be partly overcome by installation of quick-opening devices which either increase the rate of discharge of air from the piping or accelerate opening of the dry valve when one or more sprinklers operate, depending upon the type of device used.

OBS

quick-opening device: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Robinetterie et accessoires
  • Installations fixes de secours (incendies)
OBS

Accélérateur et exhausteur. Ces matériels ne sont utilisés que dans les postes à air et alternatifs. Ils ont pour objet d'accélérer l'évacuation de l'air, donc de diminuer le temps d'arrivée de l'eau aux sprinkleurs qui ont déclenché.

OBS

dispositif d'ouverture rapide : terme uniformisé par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 1

Record 2 2017-05-31

English

Subject field(s)
  • Fire Detection
  • Fire-Fighting and Rescue Equipment
  • Fixed Rescue Facilities (fire)
DEF

A dry sprinkler system in which automatic devices charge the pipes before the individual heads open and begin to discharge the extinguishing agent.

CONT

Pre-action Systems : Pre-action systems are dry-pipe systems in which the air in the piping may or may not be under pressure. When a fire occurs, a supplementary fire detecting device in the protected area is actuated. This opens a valve which permits water to flow into the piping system before a sprinkler is activated. Then there is no further delay when a sprinkler is subsequently opened by the heat of the fire.

OBS

preaction sprinkler system; preaction system: terms officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Détection des incendies
  • Matériel de secours et de lutte (incendies)
  • Installations fixes de secours (incendies)
DEF

Système composé d'extincteurs automatiques fixés à un réseau de tuyauterie contenant de l'air pouvant ou non être sous pression, et muni d'une installation de détection d'incendie située dans les mêmes zones que les extincteurs automatiques; le déclenchement du système de détection, causé par un incendie, ouvre un robinet qui permet à l'eau de pénétrer dans tout le réseau de tuyauterie et de couler par les extincteurs automatiques qui sont ouverts.

OBS

système d'extincteurs automatiques à préaction; système à préaction : termes uniformisés par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 2

Record 3 2017-01-25

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Taps and Plumbing Accessories
DEF

A ball valve in which the ball is pushed against or away from its seat by fluid pressure opposed to the action of a spring.

OBS

[A ball-check valve is] a spring-operated check valve in a piping system; when the fluid flows in one direction, pressure against a movable ball allows [the] fluid to pass; when the direction of [the] flow is reversed, the ball is forced against a seat, thereby stopping the flow.

OBS

ball check valve: term officially approved by the Lexicon Project Committee (New Brunswick).

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Robinetterie et accessoires
DEF

Clapet de non-retour dont l'obturateur est constitué d'une sphère libre venant s'appliquer sur un siège conique ou sphérique.

CONT

Si un clapet à bille permet d'obtenir une étanchéité presque parfaite, la bille peut vibrer à cause du manque d'amortissement. C'est la raison pour laquelle on remplace la bille par un piston cylindrique [...] à tête tronconique ou sphérique.

OBS

clapet à bille : terme uniformisé par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Maintenance.

OBS

clapet à billes; clapet de retenue à billes : termes uniformisés par le Comité du projet de lexiques (Nouveau-Brunswick).

Spanish

Save record 3

Record 4 2014-08-22

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Pipes and Fittings
  • Nuclear Power Stations
  • Nuclear Fission Reactors
DEF

A valve in the piping that penetrates the reactor containment, whose purpose is to shut off the containment system from the said piping.

CONT

Systems directly connected to [the] heat transport system and which may be open during normal operation of the station shall also be provided with the same isolation as the normally closed system except that manual isolating valves inside the containment structure shall not be used. At least one of the two isolation valves shall be either an automatic isolation valve (for instance, a check valve) or a powered isolation valve operable from the control room.

OBS

isolation valve: term and definition standardized by ISO in 1997.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Tuyauterie et raccords
  • Centrales nucléaires
  • Réacteurs nucléaires de fission
DEF

Vanne sur la tuyauterie traversant l'enceinte de confinement d'un réacteur, dont le rôle est d'isoler le système de confinement de ladite tuyauterie.

CONT

Les systèmes directement liés au circuit caloporteur qui peuvent être ouverts en cours d'exploitation normale de la centrale, doivent être munis des mêmes dispositifs d'isolement que tout système normalement fermé, si ce n'est que l'on ne doit pas utiliser de vannes manuelles à l'intérieur de l'enceinte. Il faut que l'une des deux vannes d'isolement au moins soit automatique (un clapet par exemple) ou actionnée depuis la salle de commande.

OBS

vanne d'isolement : terme et définition normalisés par l'ISO en 1997.

Spanish

Save record 4

Record 5 2014-05-30

English

Subject field(s)
  • Equipment (Oil and Natural Gas Extraction)
  • Oil Drilling
DEF

The entire well control equipment comprising a blowout preventer valve, an accumulator and a piping system providing a safe flow of liquid or gas during the drilling, completion, conversion and closing of a well...

Key term(s)
  • blow-out prevention system

French

Domaine(s)
  • Outillage (Extraction du pétrole et du gaz)
  • Forage des puits de pétrole
DEF

Ensemble des équipements de contrôle d'un puits comprenant un obturateur, un accumulateur ainsi qu'un réseau de conduites permettant un écoulement sécuritaire de liquide ou de gaz lors des opérations de forage, de complétion, de modification et de fermeture d'un puits.

Key term(s)
  • système antiéruption

Spanish

Save record 5

Record 6 2010-02-10

English

Subject field(s)
  • Fixed Rescue Facilities (fire)
CONT

... dry pipe sprinkler systems have more corrosion, rust, and scale build up in the sprinkler piping system than in wet pipe systems. This build up is mainly due to the presence of oxygen and moisture in the sprinkler piping. Moisture and condensation from room humidity, air supply drawn by the dry pipe air compressor, and wetting the pipe wall by accidental tripping of the dry pipe valve, and by full flow trip tests... furthers the development of scale.

OBS

Source "a" : Communications Canada, Technical Papers : Fire Protection; Paul Baril, Museum Assistance Program.

French

Domaine(s)
  • Installations fixes de secours (incendies)
OBS

Dry (pipe sprinkler) system : installation d'extinction automatique à eau sous air; [...]

Spanish

Save record 6

Record 7 2008-02-06

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Aircraft Systems
OBS

check valve : A device for automatically limiting flow in a piping system to a single direction.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Circuits des aéronefs
OBS

clapet réducteur de débit : terme uniformisé par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Opérations aériennes.

OBS

clapet réducteur : terme uniformisé par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Maintenance.

Spanish

Save record 7

Record 8 2007-11-15

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Aircraft Systems
OBS

vacuum breaker: A valve used to break a vacuum by admitting air.

OBS

check valve : A device for automatically limiting flow in a piping system to a single direction.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Circuits des aéronefs
OBS

Le casse vide [...] est un mécanisme simple et fiable. Il permet d'éviter tous les problèmes de vides incontrôlés liés, notamment, à de la condensation de la vapeur dans une tuyauterie ou une enceinte vapeur.

OBS

clapet antidépression; clapet casse-vide : termes uniformisés par le Comité d'uniformisation de la terminologie aéronautique (CUTA) - Maintenance.

Spanish

Save record 8

Record 9 2000-02-15

English

Subject field(s)
  • Urban Furnishings and Equipment
  • Sewers and Drainage
CONT

Drainage piping serving fixtures which have flood level rims located below less than twelve(12) inches(304. 8 mm) above the elevation of the next upstream manhole and/or flushing inlet cover at the public or private sewer system serving such drainage piping shall be protected from backflow of sewage by installing an approved type backwater valve.

French

Domaine(s)
  • Équipements urbains
  • Égouts et drainage
DEF

Dalle ou plaque amovible, circulaire ou carrée, avec laquelle on obture l'orifice d'un regard, d'une bouche d'égout, d'un puisard, d'une fosse septique, d'un trou d'homme, d'une trappe de visite, d'un tabernacle, etc.

Spanish

Save record 9

Record 10 - external organization data 1994-10-18

English

Subject field(s)
  • Pipes and Fittings
  • Nuclear Science and Technology
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Small Lines. For ductile piping of small bore, crimping of the pipe is a possible means of providing an isolation barrier instead of a valve.... In the case of primary heat transport system instrument lines, the following extra conditions are required :... the relevant release limits must be shown not to be exceeded during the period in which the reactor is shut down consequent to the failure, and the crimping is executed....

French

Domaine(s)
  • Tuyauterie et raccords
  • Sciences et techniques nucléaires
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Petites canalisations. Pour les canalisations ductiles de faible calibre, le fait de les aplatir peut tenir lieu de barrière d'isolement à la place d'une vanne. [...] Dans le cas des canalisations reliées aux appareils de mesure du circuit caloporteur primaire, les conditions supplémentaires suivantes doivent être remplies : [...] les mesures de rejet ne doivent pas dépasser les limites pertinentes au cours de la période pendant laquelle le réacteur est neutralisé après une défaillance, et que l'aplatissement est effectué [...]

Spanish

Save record 10

Record 11 1993-12-24

English

Subject field(s)
  • Metrology and Units of Measure
CONT

A tank and its piping system and any equipment or accessories that can affect its accuracy of measurement shall be of such design, composition and construction that when a delivery is made from any capacity indication, the quantity of liquid delivered through any discharge valve rigidly connected to the tank is within the prescribed limits of error for the [vehicle] tank.

OBS

prescribed limit of error: Consolidation of the Weights and Measures Regulations, March 1990, s. 297.

French

Domaine(s)
  • Unités de mesure et métrologie
OBS

marge de tolérance prescrite : Consolidation des Règlements sur les poids et mesures, mars 1990, article 297.

Spanish

Save record 11

Record 12 1993-06-09

English

Subject field(s)
  • Compressors
  • Pipes and Fittings
CONT

If the air system is large enough in volume so that no air receiver is used, a condensate leg with drain valve should be placed in the piping at a joint as far from the compressor as possible and just ahead of the point at which the air is used. This leg should be kept drained by use of a drain cock, and all the piping should slope toward it.

OBS

Figure 6.

French

Domaine(s)
  • Compresseurs
  • Tuyauterie et raccords
CONT

Dans le cas d'un système d'air comprimé important ne nécessitant pas de réservoir, la tuyauterie devrait comporter une canalisation verticale de purge, en un point aussi éloigné que possible du compresseur et immédiatement en amont du point de distribution. Cette canalisation doit être piquée au point bas de la tuyauterie et être munie d'un robinet de purge.

Spanish

Save record 12

Record 13 1991-10-31

English

Subject field(s)
  • Fixed Rescue Facilities (fire)
  • Fire Detection
CONT

Dry-pipe automatic sprinkler system. Has heat-operated sprinklers attached to a piping system containing air under pressure. When a sprinkler operates, the air pressure is reduced, a "dry-pipe" valve is opened by water pressure and water flows to any opened sprinklers.

French

Domaine(s)
  • Installations fixes de secours (incendies)
  • Détection des incendies
OBS

Les extincteurs automatiques à eau pulvérisée : Ces systèmes sont employés pour la protection de locaux où sont entreposés des produits présentant des dangers particuliers (...) [;] leur fonctionnement est identique à ceux des extincteurs automatiques à eau, mais leur déclenchement s'effectue soit par des détecteurs thermiques fonctionnant sous l'effet de la chaleur ou soit par des détecteurs fonctionnant sous l'effet des fumées ou des gaz.

OBS

Sprinkleur (tête de sprinkleur) : Dispositif sensible à la chaleur conçu pour réagir à une température prédéterminée en libérant automatiquement un flux d'eau réparti uniformément au niveau du sol, la forme, la quantité et la surface d'arrosage étant spécifiées.

OBS

Tête d'extincteur automatique, tête d'extincteur : Diffuseur fixe normalement fermé par un obturateur inoxydable maintenu en place par un dispositif sensible à la chaleur, et par l'orifice duquel l'eau jaillit automatiquement sous l'action des flammes ou lorsque l'air ambiant atteint une température donnée.

Spanish

Save record 13

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: