TERMIUM Plus®
The Government of Canada’s terminology and linguistic data bank.
SAGNAC EFFECT ROTATING RING INTERFEROMETER [2 records]
Record 1 - internal organization data 2001-12-10
Record 1, English
Record 1, Subject field(s)
- Optics
- Aircraft Piloting and Navigation
- Navigation Instruments
- Flight Instruments and Equipment (Aeroindustry)
Record 1, Main entry term, English
- rotating ring interferometer
1, record 1, English, rotating%20ring%20interferometer
correct
Record 1, Abbreviations, English
Record 1, Synonyms, English
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
The Sagnac effect... is understood as a phase shift of one counterpropagating wave with respect to another wave of this mode in a rotating ring interferometer, the shift being directly proportional to the angular velocity of rotation, the area enclosed by the interferometer, and the wave frequency. The Sagnac effect applies to a kinematic effect of the special theory of relativity(STR) and... ensues from the relativistic law of velocity composition. 2, record 1, English, - rotating%20ring%20interferometer
Record number: 1, Textual support number: 2 CONT
In the present development, the principle of operation of the ring laser gyro will be based on the "Sagnac Effect" rotating ring interferometer. 3, record 1, English, - rotating%20ring%20interferometer
Record 1, French
Record 1, Domaine(s)
- Optique
- Pilotage et navigation aérienne
- Instruments de navigation
- Instruments et équipement de bord (Constructions aéronautiques)
Record 1, Main entry term, French
- interféromètre annulaire
1, record 1, French, interf%C3%A9rom%C3%A8tre%20annulaire
correct, masculine noun
Record 1, Abbreviations, French
Record 1, Synonyms, French
- interféromètre circulaire 2, record 1, French, interf%C3%A9rom%C3%A8tre%20circulaire
correct, masculine noun
Record 1, Textual support, French
Record number: 1, Textual support number: 1 CONT
Le but de notre expérience est de mesurer une accélération angulaire. Pour ce faire, un interféromètre à effet Sagnac sera utilisé. Il s'agit d'un dispositif expérimental permettant l'analyse d'une figure d'interférence produite par un faisceau laser. Le faisceau est coupé en deux par un miroir semi-transparent et, à la différence de l'interféromètre de Michelson, le trajet suivi par les rayons est circulaire. Chaque rayon tourne dans un sens différent et donc, selon l'état de rotation du système, le déphasage entre les rayons est sensible à l'accélération angulaire du dispositif. Quand l'interféromètre de Michelson permet de mesurer une accélération linéaire, l'interféromètre à effet Sagnac permet de mesurer une accélération angulaire. Le principe de cet effet correspond à un effet Doppler rotationnel. Il a été découvert par Sagnac en 1913. Cet interféromètre annulaire se résume en deux formules. 1, record 1, French, - interf%C3%A9rom%C3%A8tre%20annulaire
Record number: 1, Textual support number: 2 CONT
Calcul de la différence de marche pour un interféromètre de Sagnac circulaire (lois classiques). 2, record 1, French, - interf%C3%A9rom%C3%A8tre%20annulaire
Record 1, Spanish
Record 1, Textual support, Spanish
Record 2 - internal organization data 2001-06-21
Record 2, English
Record 2, Subject field(s)
- Optics
- Aircraft Piloting and Navigation
- Navigation Instruments
- Flight Instruments and Equipment (Aeroindustry)
Record 2, Main entry term, English
- Sagnac effect rotating ring interferometer
1, record 2, English, Sagnac%20effect%20rotating%20ring%20interferometer
correct
Record 2, Abbreviations, English
Record 2, Synonyms, English
Record 2, Textual support, English
Record number: 2, Textual support number: 1 CONT
In the present development, the principle of operation of the ring laser gyro will be based on the "Sagnac effect" rotating ring interferometer. 1, record 2, English, - Sagnac%20effect%20rotating%20ring%20interferometer
Record number: 2, Textual support number: 1 OBS
The Sagnac effect... is understood as a phase shift of one counterpropagating wave with respect to another wave of this mode in a rotating ring interferometer, the shift being directly proportional to the angular velocity of rotation, the area enclosed by the interferometer, and the wave frequency. The Sagnac effect applies to a kinematic effect of the special theory of relativity(STR) and... ensues from the relativistic law of velocity composition. 2, record 2, English, - Sagnac%20effect%20rotating%20ring%20interferometer
Record 2, French
Record 2, Domaine(s)
- Optique
- Pilotage et navigation aérienne
- Instruments de navigation
- Instruments et équipement de bord (Constructions aéronautiques)
Record 2, Main entry term, French
- interféromètre de Sagnac circulaire
1, record 2, French, interf%C3%A9rom%C3%A8tre%20de%20Sagnac%20circulaire
correct, masculine noun
Record 2, Abbreviations, French
Record 2, Synonyms, French
- interféromètre annulaire à effet Sagnac 2, record 2, French, interf%C3%A9rom%C3%A8tre%20annulaire%20%C3%A0%20effet%20Sagnac
masculine noun
Record 2, Textual support, French
Record number: 2, Textual support number: 1 CONT
Calcul de la différence de marche pour un interféromètre de Sagnac circulaire (lois classiques). 1, record 2, French, - interf%C3%A9rom%C3%A8tre%20de%20Sagnac%20circulaire
Record number: 2, Textual support number: 1 OBS
Le but de notre expérience est de mesurer une accélération angulaire. Pour ce faire, un interféromètre à effet Sagnac sera utilisé. Il s'agit d'un dispositif expérimental permettant l'analyse d'une figure d'interférence produite par un faisceau laser. Le faisceau est coupé en deux par un miroir semi-transparent et, à la différence de l'interféromètre de Michelson, le trajet suivi par les rayons est circulaire. Chaque rayon tourne dans un sens différent et donc, selon l'état de rotation du système, le déphasage entre les rayons est sensible à l'accélération angulaire du dispositif. Quand l'interféromètre de Michelson permet de mesurer une accélération linéaire, l'interféromètre à effet Sagnac permet de mesurer une accélération angulaire. Le principe de cet effet correspond à un effet Doppler rotationnel. Il a été découvert par Sagnac en 1913. Cet interféromètre annulaire se résume en deux formules. 3, record 2, French, - interf%C3%A9rom%C3%A8tre%20de%20Sagnac%20circulaire
Record 2, Spanish
Record 2, Textual support, Spanish
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.
- Date Modified: