TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

SHAPING AMPLIFIER [2 records]

Record 1 2012-01-09

English

Subject field(s)
  • Amplifiers (Electronics)
  • Radiological Physics (Theory and Application)
CONT

Pole-zero cancellation(Tail cancellation) … we approximated the preamp output pulse as a step function, however, in a real preamp pulse, the falling tail is a long exponential decay instead of a simple step function. Consequently, there is a small amplitude undershoot starting at about 7τ. This undershoot decays back to baseline with the long time constant of the preamplifier. At medium to high counting rates, a substantial fraction of the amplifier output pulses will ride on the undershoot from a previous pulse. The apparent pulse amplitudes measured for these pulses will be significantly lower, which deteriorates the energy resolution. Most shaping amplifiers incorporate a pole-zero cancellation circuit to eliminate this undershoot. The benefit of pole-zero cancellation is improved peak shapes and resolution in the energy spectrum at high counting rates.

Key term(s)
  • pole zero cancellation circuit

French

Domaine(s)
  • Amplificateurs (Électronique)
  • Physique radiologique et applications
CONT

Circuit de compensation du passage à zéro (PZC : Pole Zero Cancellation) : parce que le signal d’entrée n’est pas rigoureusement un signal marche mais décroît lentement, le signal unipolaire va couper la ligne de base puis regagner celle-ci avec les constantes de temps du préamplificateur (des ms [millisecondes]). Au lieu de partir de la ligne de base, un signal va donc débuter sur la queue d’un signal précédent, c’est-à-dire sur une valeur légèrement négative. Son amplitude mesurée par rapport à la ligne de base est un peu trop faible et cela va se traduire par un élargissement des pics du côté des basses énergies.

Spanish

Save record 1

Record 2 2010-11-26

English

Subject field(s)
  • Electrical Engineering
  • Radiological Physics (Theory and Application)
CONT

[Nuclear radiation detector. ] Pile-Up Rejection. If two pulses arrive within the so-called measurement time(peaking time) the output pulse will have a distorted amplitude. The pile-up rejector circuit is used to prevent the measurement of these distorted pulses. The pile-up rejector is implemented by adding a fast pulse-shaping amplifier with a very short shaping time constant in parallel with the slow spectroscopy amplifier.

Key term(s)
  • pileup rejector circuit
  • pileup rejection system
  • pileup rejector

French

Domaine(s)
  • Électrotechnique
  • Physique radiologique et applications
CONT

[Détecteur de rayonnements nucléaires.] Circuit anti-empilement […] : si le temps séparant deux événements est plus court que la durée du signal en sortie d’amplificateur, ces deux signaux vont s’empiler. Pour réduire ce phénomène, on peut diminuer les constantes de temps mais on élargit la bande passante et on diminue le rapport signal/bruit. Par ailleurs avec des constantes de temps qui ne seraient plus assez grandes devant le temps de montée du signal issu du pré-amplificateur, le défaut balistique n’est plus constant. Le rôle du circuit anti-empilement est de rejeter le signal si un deuxième événement survient dans un temps inférieur à la durée de l’impulsion.

Spanish

Save record 2

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: