TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

SIGNAL SENSITIVITY [16 records]

Record 1 2014-03-21

English

Subject field(s)
  • Television (Radioelectricity)
CONT

The next step is shading correction, which compensates for uneven illumination, optical losses, and uneven tube sensitivity. Color masking and gamma correction are implemented on logarithmic signals, and the resulting signal is exponentiated for display.

French

Domaine(s)
  • Télévision (Radioélectricité)

Spanish

Campo(s) temático(s)
  • Televisión (Radioelectricidad)
Save record 1

Record 2 2013-07-16

English

Subject field(s)
  • Remote Sensing
  • Cartography
DEF

The sensitivity of a remote-sensing detector to [discriminate] differences in signal strength as it records the radiant flux reflected or emitted from the terrain.

CONT

Radiometric resolution, or radiometric sensitivity refers to the number of digital levels used to express the data collected by the sensor. In general, the greater the number of levels, the greater the detail of information. The number of levels is normally expressed as the number of binary digits needed to store the value of the maximum level, for example a radiometric resolution of 1 bit would be 2 levels, 2 bits would be 4 levels and 8 bits would be 256 levels. The number of levels is often referred to as the Digital Number, or DN value.

OBS

radiometric resolution: term officially approved by the RADARSAT-2 Terminology Approval Group (RTAG).

French

Domaine(s)
  • Télédétection
  • Cartographie
DEF

La plus petite différence d'intensité entre deux niveaux du signal radiométrique détectée par le «capteur» utilisé.

CONT

La résolution radiométrique fait référence à la plage dynamique, c'est-à-dire à la gamme des longueurs d'onde à l'intérieur de laquelle un capteur est sensible. La gamme dynamique de la plupart des données satellitaires est de 7 bits ou 128 niveaux d'intensité (Landsat MSS, IRS), ou 256 niveaux (8 bits) pour Landsat TM, ETM.

OBS

résolution radiométrique : terme uniformisé par le Groupe de travail de la terminologie de RADARSAT-2 (GTTR).

PHR

Limite de résolution radiométrique.

Spanish

Campo(s) temático(s)
  • Teledetección
  • Cartografía
Save record 2

Record 3 2012-01-05

English

Subject field(s)
  • Remote Sensing
  • Telecommunications Transmission
CONT

The residual phase noise information is needed because of that specific synthesizer's sensitivity to the phase noise of the external frequency reference, and the fact that its phase noise performance is potentially degraded by using a noisy external frequency reference signal.

French

Domaine(s)
  • Télédétection
  • Transmission (Télécommunications)
CONT

Ce signal de référence de fréquence est acquis de façon entrelacée avec le signal d’intérêt en utilisant une seule chaîne d’acquisition. Cette approche exploite la possibilité offerte par les spectromètres modernes de traiter les données en temps réel et ne nécessite pas de modification significative du spectromètre.

Spanish

Save record 3

Record 4 2011-12-22

English

Subject field(s)
  • Atomic Physics
CONT

… He neutron detectors … permit the counting of the delayed photofission signal. They are generally optimized in a known manner in order to have an optimum sensitivity at a given energy, e. g. 400 keV [kiloelectronvolts].

French

Domaine(s)
  • Physique atomique
CONT

La méthode SPHINCS consiste en une irradiation photonique composée de plusieurs impulsions de photons de même largeur temporelle, espacées de périodes «blanches» pendant lesquelles aucun photon n’est émis. Les photons interrogateurs induisent des réactions de photofission sur les actinides présents. La signature de ces réactions est le signal retardé de photofission. La seconde étape consiste à mesurer en interpulses (pendant la période «blanche») la signature due aux neutrons retardés de photofission.

OBS

SPHINCS : Sequential PHoton Interrogation and Neutron Counting Signatures.

Spanish

Save record 4

Record 5 2006-02-21

English

Subject field(s)
  • Analytical Chemistry
CONT

Piezoelectric Sorption Detector. Piezoelectric quartz crystal, long used as frequency and time standards to one part in 108 or better, have been shown by King to be selective gas detectors when coated with various chromatographic liquid phases. Used as detectors, such coated crystals have several advantages :(1) sensitivity increases with solute or sample boiling point,(2) detectors selective to compound type can be made with response times of the order of 0. 05 sec, and(3) the output signal is a frequency which simplifies integration of peak areas and digital presentation of data.

Key term(s)
  • piezo-electric sorption detector

French

Domaine(s)
  • Chimie analytique
OBS

piézoélectrique : Cette graphie, puisée des Rectifications de l'orthographe recommandées par le Conseil supérieur de la langue française, est attestée dans le Petit Robert (2004).

Key term(s)
  • détecteur piézo-électrique

Spanish

Save record 5

Record 6 2005-08-23

English

Subject field(s)
  • Acoustics (Physics)
CONT

A-weighting. A system of adjusting signal to noise ratio measurements to take into account the differing sensitivity of the human ear to different frequencies. Thus an A-weighted signal to noise ratio more accurately reflects how a system's noise performance will be perceived than an unweighted measure.

French

Domaine(s)
  • Acoustique (Physique)
DEF

Rapport signal-bruit dont la mesure est ajustée en prenant en compte le spectre de sensibilité de l'oreille humaine face à différentes fréquences.

Spanish

Save record 6

Record 7 2004-12-02

English

Subject field(s)
  • Spacecraft
CONT

The SSUSI [Special Sensor Ultraviolet Spectrographic Imager] mission sensor contains a line scanning imaging spectrograph covering the far ultraviolet spectrum, and high sensitivity, nadir viewing photometers operating at 630 nm(with separate signal and background measurements) and 427. 8 nm.

French

Domaine(s)
  • Engins spatiaux
DEF

Capteur réalisant des mesures qui font partie de l'objet de la mission d'un engin spatial.

OBS

capteur de mission : terme uniformisé par le Comité d'uniformisation de la terminologie spatiale - CUTS.

Spanish

Save record 7

Record 8 2003-09-09

English

Subject field(s)
  • Telephone Metering
  • Acoustics (Physics)
  • Noise Pollution
CONT

Sound levels are measured in A-weighted decibels which adjust sound pressure to conform with the frequency response of the human ear.

OBS

decibels relative to 2x10 (-5th power) Pa and measured as per ANSI Standard S1.4 using the A weighting scale.

CONT

The unit of measurement of environmental noise is the decibel(dB). To better approximate the range of sensitivity of the human ear to sounds of different frequencies, the A-weighted decibel scale was devised. Because the human ear is less sensitive to low-frequency sounds, the A-scale de-emphasizes these frequencies by incorporating frequency weighting of the sound signal. When the A-scale is used, the decibel levels are shown as dBA. On this scale, the range of human hearing extends from about 3 dBA to about 140 dBA. A 10-dBA increase is perceived by most people as a doubling of the sound level. The smallest change that can be heard is about 2 to 3 dBA.

French

Domaine(s)
  • Téléphonométrie
  • Acoustique (Physique)
  • Pollution par le bruit
CONT

[...] les acousticiens ont établi trois courbes de pondération, dites courbes A, B, C, qui permettent, à partir de la mesure objective du bruit, d'évaluer la sensation subjective qui s'y rapporte. Ces courbes correspondent à des réseaux pondérateurs [...]. Dans la pratique, ces réseaux sont incorporés au sonomètre et peuvent être mis en circuit à l'aide d'un commutateur; on obtient ainsi les lectures dites en «gamme A, B ou C», ou encore en décibels A, B, ou C.

CONT

Le décibel pondéré en gamme A(dBA) est l'unité de mesure normale du son. Comme l'intensité du bruit augmente de façon exponentielle, une faible hausse du niveau dBA peut entraîner une augmentation considérable du bruit perçu.

Spanish

Campo(s) temático(s)
  • Telefonometría
  • Acústica (Física)
  • Contaminación acústica
DEF

Unidad de medida del ruido basada en la Curva Standard de Ponderación A, que es la que más se aproxima en sus respuestas ante diferentes frecuencias a la forma de captar el sonido el oído humano.

CONT

El decibelio A (dBA) indica que en la medición acústica se ha tenido en cuenta la ponderación A según las frecuencias del sonido. El decibelio A ofrece una valoración del sonido teniendo en cuenta la sensibilidad propia del oído humano.

Save record 8

Record 9 2001-08-23

English

Subject field(s)
  • Photoelectricity and Electron Optics
  • Aircraft Piloting and Navigation
  • Navigation Instruments
  • Flight Instruments and Equipment (Aeroindustry)
CONT

We describe a fiber optic voltage sensor with optically controlled sensitivity. The sensor operates at two widely separated wavelengths(633 nm and 976 nm), one of which is a control signal(976 nm). We show that at a properly chosen wavelength of the control signal and of the phase-retarding element, variations of the power of the control signal allow increases or decreases in the sensitivity of the sensor.

Key term(s)
  • phase retarding element

French

Domaine(s)
  • Photo-électricité et optique électronique
  • Pilotage et navigation aérienne
  • Instruments de navigation
  • Instruments et équipement de bord (Constructions aéronautiques)
CONT

[Gyromètre à fibre optique]. Une linéarisation et une augmentation de sensibilité peuvent être obtenues de la manière suivante : un élément retardateur de phase est placé à l'entrée du circuit anti-horaire, et donc à la sortie du circuit horaire; cet élément agit par modification locale de l'indice de réfraction du circuit optique; [...]

Spanish

Save record 9

Record 10 1999-09-30

English

Subject field(s)
  • Acoustics (Physics)
  • Noise Pollution
CONT

The unit of measurement of environmental noise is the decibel(dB). To better approximate the range of sensitivity of the human ear to sounds of different frequencies, the A-weighted decibel scale was devised. Because the human ear is less sensitive to low-frequency sounds, the A-scale de-emphasizes these frequencies by incorporating frequency weighting of the sound signal. When the A-scale is used, the decibel levels are shown as dBA. On this scale, the range of human hearing extends from about 3 dBA to about 140 dBA. A 10-dBA increase is perceived by most people as a doubling of the sound level. The smallest change that can be heard is about 2 to 3 dBA.

CONT

Sound levels are measured in A-weighted decibels which adjust sound pressure to conform with the frequency response of the human ear.

OBS

Usually found in the following expressions: A-, b-, C weighted decibels.

French

Domaine(s)
  • Acoustique (Physique)
  • Pollution par le bruit
CONT

[...] la mesure d'un bruit en décibel pondéré est une mesure globale. Cela veut dire qu'on obtient un seul chiffre pour caractériser le niveau sonore, la pondération se faisant en prenant en compte toutes les fréquences contenues dans le bruit.

CONT

Le décibel pondéré en gamme A(dBA) est l'unité de mesure normale du son. Comme l'intensité du bruit augmente de façon exponentielle, une faible hausse du niveau dBA peut entraîner une augmentation considérable du bruit perçu.

CONT

Pour les bâtiments non résidentiels, où l'on présume que les occupants sont éveillés, le niveau acoustique à l'oreille de l'occupant doit être d'au moins 5 dBA supérieur à n'importe quel autre son susceptible de persister pendant plus de 30 secondes ou être au moins égal à 65 dBA, si cette dernière valeur est supérieure. (L'unité dBA exprime le niveau de pression acoustique en décibels pondéré pour simuler la réponse de l'ouïe humaine, qui n'a pas la même sensibilité à toutes les fréquences.)

Spanish

Save record 10

Record 11 1999-04-23

English

Subject field(s)
  • Analytical Chemistry
DEF

In this form of transport detector for h. p. l. c. [high-performance liquid chromatography], the eluate is deposited upon a fine stainless steel wire that has been cleaned by being heated at 850°C. The volatile solvent is evaporated and the solute oxidized at 700-800°C in air to a mixture of carbon dioxide and water. The oxidation products are mixed with hydrogen and passed over a nickel catalyst at 330°C to give methane which is burnt in a flame ionization detector to give an electrical signal that can be amplified and recorded. The detector gives a linear response over a wide concentration range [...] The sensitivity has been improved and the noise level reduced by using either a ceramic(kaolin) or ceramic-metal(kaolin and copper) coating to the wire.

Key term(s)
  • moving-wire detector
  • moving-filament detector

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 11

Record 12 1996-05-10

English

Subject field(s)
  • Analytical Chemistry
CONT

A potential problem in using UV detectors operated at high sensitivity is distinguishing between sample peaks and pseudopeaks due to refraction effects that affect the detector signal.

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 12

Record 13 1996-03-08

English

Subject field(s)
  • Analytical Chemistry
CONT

Lovelock developed a small detector intended for use with open tubular columns, and a new triode detector having a sensitivity 1000 times greater than his original detector... The triode detector... incorporates a ring electrode, in addition to the normal anode and cathode electrodes, which separates the background current(positive ions liberated by vapor/metastable argon reactions or collisions) of the primary electron stream from the signal current. Basically, both detectors are similar to the simple device in design : their brass or stainless steel chambers function as cathodes; their anodes of the same material are supported coaxially within the chamber by a polytetrafluoroethylene insulator; both contain ports for introduction and escape of the chromatographic column gas effluent from the detectors; and each have a suitable source of alpha or beta radiation.

Key term(s)
  • Lovelock's detector

French

Domaine(s)
  • Chimie analytique

Spanish

Save record 13

Record 14 1993-03-09

English

Subject field(s)
  • Electrical Networks
  • Equipment and Tools (Water Supply)
CONT

If the transmitter and receiver are operated too close to each other or with a too high setting of the SENSITIVITY control during inductive operation there is the definite possibility of a false signal due to direct air coupling.

French

Domaine(s)
  • Réseaux électriques
  • Équipement et outillage (Alimentation en eau)
CONT

En mode induction, lorsque l'émetteur et le récepteur sont placés trop près l'un de l'autre ou que la commande SENSITIVITY est réglée à une position trop élevée, il est très probable que le récepteur capte un faux signal dû à un couplage direct dans l'air.

Spanish

Save record 14

Record 15 1991-11-08

English

Subject field(s)
  • Statistics
OBS

"Comparing models... gives some indication of the sensitivity of the signal model to changes in 02c, the innovation variance of the sampling error model... ", Survey Methodology, 16-2, Bell & Hillmer, section 5. 3) innovations=the one step ahead prediction errors.

French

Domaine(s)
  • Statistique
OBS

(une étape à l'avance).

OBS

"innovations" se rend par "résidus" (source : Statistique Canada, publication n° 12-564).

Spanish

Save record 15

Record 16 1989-09-08

English

Subject field(s)
  • Radar, Radio Guidance and Goniometry
DEF

The reduction in sensitivity of a scanning radar due to motion of the beam between transmission and reception of the signal.

French

Domaine(s)
  • Radar, radioguidage et radiogoniométrie

Spanish

Save record 16

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: