Record 1 2026-02-26

English

Subject field(s)
  • Artificial Intelligence
CONT

Linear threshold units (LTUs) were originally proposed as models of biological neurons. They were widely studied in the context of the perceptron ... Due to the difficulties of finding a general algorithm for networks with hidden nodes, they never passed into general use.

CONT

Regarding the advantage of depth, early theoretical results have focused on circuit operations(neural net unit computations) that are substantially different from those being used in real state-of-the-art deep learning applications, such as logic gates... and linear threshold units with non-negative weights...

French

Domaine(s)
  • Intelligence artificielle
CONT

Le perceptron est l'une des architectures des réseaux de neurones les plus simples[. Son architecture] est formée de deux couches : une couche d'entrée et une couche de sortie. La couche d'entrée représente les neurones d'entrée qui permettent de sortir les mêmes entrées fournies. La couche de sortie représente un type de neurone artificiel différent des autres, appelé «unité linéaire à seuil (ULS)» [...] Chaque neurone ULS est connecté à toutes les neurones d'entrées et aussi à un neurone particulier appelé «neurone de biais» dont la sortie est toujours égale à 1 (neurone de terme constant).

Spanish

Campo(s) temático(s)
  • Inteligencia artificial
CONT

El perceptrón es una de las arquitecturas de redes neuronales más simples, basado en una neurona artificial [que se] conoce como [...] unidad de umbral lineal [...]

Save record 1

Record 2 - external organization data 2011-04-11

English

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Radiation Protection
  • Compartment - Canadian Nuclear Safety Commission
CONT

The skin dose (surface dose) is the radiation delivered at the skin. It is the sum of the dose from the incident radiation plus the dose from the backscatter radiation.

CONT

Skin dose. The limit for skin is set by reference to deterministic(formerly known as non-stochastic) effects. These are effects such as reddening or ulceration of the skin which vary in intensity in proportion to the dose, and also have a threshold dose below which no effects appear. The proposed limit, which is below the threshold, is 500 mSv in any dosimetry year, averaged over any 1 cm² area at a nominal depth of 7 mg cm², regardless of the area exposed.

French

Domaine(s)
  • Physique radiologique et applications
  • Radioprotection
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

La limite de la dose à la peau est fixée par référence aux effets déterministes (anciennement non stochastiques). Ce sont des effets comme le rougissement ou l'ulcération de la peau dont l'intensité est proportionnelle à la dose et pour lesquels il existe un seuil de dose sous lequel aucun effet se manifeste. La limite proposée, soit 500 mSv par année de dosimétrie, est inférieure à ce seuil et est établie selon une moyenne calculée sur une superficie de 1 cm² à une profondeur nominale de 7 mg cm², peu importe la superficie exposée.

Spanish

Save record 2

Record 3 - external organization data 2009-03-01

English

Subject field(s)
  • Radiological Physics (Theory and Application)
  • Radiation Protection
  • Compartment - Canadian Nuclear Safety Commission
DEF

Non stochastic effects : Effects for which the severity of the effect varies with dose, and for which a threshold may therefore exist.

CONT

The limit for skin is set by reference to deterministic(formerly known as non-stochastic) effects. These are effects such as reddening or ulceration of the skin which vary in intensity in proportion to the dose, and also have a threshold dose below which no effects appear. The proposed limit, which is below the threshold, is 500 mSv in any dosimetry year, averaged over any 1 cm² area at a nominal depth of 7 mg cm², regardless of the area exposed.

French

Domaine(s)
  • Physique radiologique et applications
  • Radioprotection
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Effets biologiques qui ne se produisent que si un certain seuil de dose est dépassé, et dont la gravité augmente proportionnellement à la dose absorbée; des rougeurs sur la peau, des lésions vasculaires aux tissus, l'opacité des cristallins et des maux aigus dus aux rayonnements [...] [en sont des] exemples [...]

CONT

La limite de la dose à la peau est fixée par référence aux effets déterministes (anciennement non stochastiques). Ce sont des effets comme le rougissement ou l'ulcération de la peau dont l'intensité est proportionnelle à la dose et pour lesquels il existe un seuil de dose sous lequel aucun effet se manifeste. La limite proposée, soit 500 mSv par année de dosimétrie, est inférieure à ce seuil et est établie selon une moyenne calculée sur une superficie de 1 cm² à une profondeur nominale de 7 mg cm², peu importe la superficie exposée.

Spanish

Save record 3

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: