TERMIUM Plus®

The Government of Canada’s terminology and linguistic data bank.

FIRING RATE [47 records]

Record 1 2023-01-10

English

Subject field(s)
  • Weapon Systems
DEF

The rate at which a weapon fires or launches munitions. [Definition officially approved by the Joint Terminology Panel.]

DEF

The number of rounds fired per weapon per minute. [Definition standardized by NATO.]

OBS

rate of fire; RoF; firing rate : designations officially approved by the Joint Terminology Panel.

OBS

rate of fire: designation standardized by NATO.

Key term(s)
  • fire rate

French

Domaine(s)
  • Systèmes d'armes
DEF

Cadence à laquelle une arme tire ou lance des munitions. [Définition uniformisée par le Groupe d'experts en terminologie interarmées.]

DEF

Nombre de coups tirés par une arme en une minute. [Définition normalisée par l'OTAN et uniformisée par le Conseil de doctrine et de tactique de l'Armée de terre.]

OBS

cadence de tir; CT : désignations uniformisées par le Groupe d'experts en terminologie interarmées.

OBS

cadence de tir : désignation normalisée par l'OTAN et uniformisée par le Comité de terminologie française du Conseil de doctrine et de tactique de l'Armée de terre.

Spanish

Campo(s) temático(s)
  • Sistemas de armas
DEF

Número de disparos, por arma, por minuto.

Save record 1

Record 2 2021-09-22

English

Subject field(s)
  • Weapon Systems
CONT

The Lewis Mark 1 had a gas operated, automatic action and was recognisable by its distinctive cooling barrel. The design of the gun allowed rapid firing with the rate of fire approximately 500-600 rounds per minute.

French

Domaine(s)
  • Systèmes d'armes
CONT

La MG 08 a été adoptée par l'armée allemande en 1908. Cette arme automatique se décompose en deux fardeaux principaux : l'arme elle-même et son affût. Son canon est refroidi par un manchon réfrigérant contenant 4 litres d'eau.

Spanish

Save record 2

Record 3 2021-01-18

English

Subject field(s)
  • Guns (Land Forces)
OBS

The rate of fire serves as a comparison means between two weapons or between a weapon that has already been in service for a few years and its most upgraded model, the C7 in the second instance for example.

French

Domaine(s)
  • Canons (Forces terrestres)
OBS

La cadence de tir s'inscrit dans le cadre d'une comparaison de rendement entre deux armes ou entre une arme déjà en service depuis quelques années et son plus récent modèle amélioré, la C7 par exemple dans le deuxième cas.

OBS

cadence de tir rapide : désignation uniformisée par le Comité de terminologie française du Conseil de doctrine et de tactique de l'Armée de terre.

Spanish

Save record 3

Record 4 2016-03-02

English

Subject field(s)
  • Nervous System
CONT

It has been suggested that sympathetic hyperactivity is found in patients with metabolic syndrome(MS) by measuring turnover rate of catecholamines and/or muscle sympathetic nerve firing rate.

French

Domaine(s)
  • Système nerveux
CONT

La responsabilité d'un dysfonctionnement sympathique dans la genèse ou l'aggravation des désordres cardiovasculaires et/ou métaboliques est actuellement retenue. En effet, une corrélation significative entre hyperactivité sympathique et différents paramètres définissant le syndrome métabolique a été prouvée.

Spanish

Save record 4

Record 5 2011-10-27

English

Subject field(s)
  • Nervous System
DEF

Outpouting a spike.

CONT

When the neuronal membrane is depolarized to about -35 mV, an action potential occurs, which represents cell "firing" and is the fundamental mechanism of neuronal signaling. Specifically, as the interior of the cell becomes more positive, specialized voltage-gated Na+ channels open, permitting more positive ions to flow into the cell.

PHR

firing rate

French

Domaine(s)
  • Système nerveux
CONT

La synchronisation de l'activité des neurones est rendue possible par leurs connexions synaptiques électriques. Cette activité rythmique d'ensemble retentit vraisemblablement sur l'activité du cortex cérébelleux. En effet, les bouffées de potentiels d'action synchronisées dans les fibres grimpantes synchronisent les décharges de populations de cellules de Purkinje.

CONT

fréquence de décharge des neurones

Spanish

Save record 5

Record 6 2011-08-25

English

Subject field(s)
  • Sonar and Underwater Detection (Military)

French

Domaine(s)
  • Sonar et détection sous-marine (Militaire)

Spanish

Save record 6

Record 7 2005-02-18

English

Subject field(s)
  • Weapon Systems

French

Domaine(s)
  • Systèmes d'armes

Spanish

Save record 7

Record 8 2001-11-05

English

Subject field(s)
  • Sonar and Underwater Detection (Military)
OBS

Detection parameter in Lofar underwater detection system.

French

Domaine(s)
  • Sonar et détection sous-marine (Militaire)

Spanish

Save record 8

Record 9 2001-01-30

English

Subject field(s)
  • Ballistics
DEF

Method of calculating firing data based on the rate of angular travel of the target in direction and elevation.

French

Domaine(s)
  • Balistique

Spanish

Save record 9

Record 10 2000-06-02

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Burners and Steamfitting
DEF

In oil burners with 2 firing rate levels(stages), the automatic safety shutoff valve which opens to admit more fuel when the higher combustion rate is required; the second stage may be optional.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Fumisterie et brûleurs
OBS

Brûleurs à fuel [...] Il existe [...] sur le marché des brûleurs à gazéification à deux allures de marche.

OBS

La plupart des installations fonctionnent par intermittence en régulation «tout ou rien», par conséquent avec brûleur à pleine marche ou à l'arrêt. Dans certaines grosses installations, on prévoit plusieurs allures.

Spanish

Save record 10

Record 11 2000-06-02

English

Subject field(s)
  • Burners and Steamfitting
  • Closing Devices and Nozzles (Mechanical Components)
DEF

In oil burners with more than 1 firing rate level(stage), the automatic safety shutoff valve which opens first to admit the fuel required for the lowest rate of combustion. In direct spark ignition systems, the first stage may take the place of a gas pilot.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Obturateurs et buses (Composants mécaniques)
OBS

Brûleurs à fuel [...] Il existe [...] sur le marché des brûleurs à gazéification à deux allures de marche.

OBS

La plupart des installations fonctionnent par intermittence en régulation «tout ou rien», par conséquent avec brûleur à pleine marche ou à l'arrêt. Dans certaines grosses installations, on prévoit plusieurs allures.

Spanish

Save record 11

Record 12 2000-06-02

English

Subject field(s)
  • Burners and Steamfitting
CONT

Flame safeguard system. The set of equipment used to provide safe control of burner operation. This usually includes the flame safeguard control, the flame detection system, all controllers, all limits and interlocks, all fuel valves, the ignition system, the firing rate control system, and any other auxiliary equipment.

Key term(s)
  • combustion safeguard

French

Domaine(s)
  • Fumisterie et brûleurs
CONT

Pour comprendre l'origine de l'expression anglaise [flame safeguard control system] et de son équivalent français [système de surveillance de flamme], il faut savoir que les ensembles du genre ont principalement pour fonction de détecter la présence d'une flamme satisfaisante et d'assurer le démarrage, l'état de régime et l'arrêt sécuritaires du brûleur. La surveillance de flamme (flame safeguard) est donc une fonction sécuritaire spécifique d'une importance telle qu'elle a valu son nom à tout le système.

CONT

Tout appareil neuf utilisant du gaz doit être équipé d'un système de surveillance de la flamme (Zündsicherung) selon la norme ITM-EN 125 respectivement de la norme DIN 3360-2.

Spanish

Save record 12

Record 13 2000-06-02

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
  • Combustion and Fuels (Fireplaces)
DEF

The range of firing rates over which satisfactory combustion may be obtained. For example, the firing rate of a burner with a 4 to 1 turndown range can be varied from 25 percent to 100 percent.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
  • Combustion et combustibles (Foyers)
OBS

taux d'allumage : exprime le taux auquel le combustible ou le mélange air-combustible arrive au brûleur.

Spanish

Save record 13

Record 14 2000-05-25

English

Subject field(s)
  • Gas and Oil Heating
  • Burners and Steamfitting
DEF

A power burner in which gas is supplied at atmospheric pressure(zero gas) maintained by a zero governor. A fan, or blower, blows the air through a venturi, where venturi action pulls the gas into the airstream. The quantity of gas drawn into the airstream is a direct function of the air velocity, so the air-fuel ratio will remain constant regardless of the air volume. The firing rate is controlled by air adjustment alone.

French

Domaine(s)
  • Chauffage au gaz et au mazout
  • Fumisterie et brûleurs
OBS

Voir la fiche «régulateur atmosphérique / zero governor».

Spanish

Save record 14

Record 15 2000-05-25

English

Subject field(s)
  • Burners and Steamfitting
  • Applications of Electronics
DEF

A controller which positions the firing rate motor to automatically regulate the burner firing rate at a predetermined air-fuel ratio in accordance with load demand. It may position the air and fuel supplies for low fire or for high fire, or it may be a proportioning(modulating) type which gradually varies the air and fuel supplies within limits to meet the load demand.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Applications de l'électronique
CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc : [...] un régulateur d'allure de chauffe (firing rate control; firing rate controller), qui règle l'allure de chauffe en fonction de la demande de chaleur, en modifiant le débit d'air ou de combustible.

Spanish

Save record 15

Record 16 2000-05-25

English

Subject field(s)
  • Burners and Steamfitting
  • Combustion and Fuels (Fireplaces)
DEF

The rate at which fuel, or an air-fuel mixture is supplied to a burner or furnace, expressed in volume, weight, or heat units supplied per unit time.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Combustion et combustibles (Foyers)
CONT

taux d'allumage, exprime le taux auquel le combustible ou le mélange air-combustible arrive au brûleur.

Spanish

Save record 16

Record 17 2000-05-25

English

Subject field(s)
  • Electrical Circuits and Circuit Breakers
  • Heating
DEF

A terminal, connection, leadwire, circuit, or other part of an electrical network which is shared by other parts of the network.

CONT

Common terminal.

OBS

On a flame safeguard control, the terminal and leadwire which are in the circuit for all positions of the firing rate switching circuit.

French

Domaine(s)
  • Circuits électriques et coupe-circuits
  • Chauffage
DEF

Qualificatif appliqué à une borne, une connexion, un conducteur, un circuit, ou un sous-ensemble quelconque jouant un rôle dans le fonctionnement de plusieurs autres organes distincts à l'intérieur d'un ensemble.

CONT

Borne commune.

OBS

En anglais, on dit souvent "common" sans le substantif qu'il devrait qualifier.

Spanish

Save record 17

Record 18 2000-05-25

English

Subject field(s)
  • Closing Devices and Nozzles (Mechanical Components)
DEF

An automatic control valve for regulating the input to a burner in response to a load demand.

French

Domaine(s)
  • Obturateurs et buses (Composants mécaniques)
OBS

régulateur. Dispositif de correction automatique d'un niveau d'eau, d'un débit, d'une pression, d'une température, d'une vitesse de rotation, d'une tension électrique, etc.

Spanish

Save record 18

Record 19 2000-04-28

English

Subject field(s)
  • Combustion and Fuels (Fireplaces)
DEF

Firing a boiler at an input rate in excess of its rated capacity. The rated capacity of a boiler is based upon its heat transfer surface area.

French

Domaine(s)
  • Combustion et combustibles (Foyers)
OBS

allure de marche / rating.

OBS

Il existe [...] sur le marché des brûleurs à deux allures de marche.

OBS

La plupart des installations fonctionnent par intermittence en régulation «tout ou rien», par conséquent avec brûleur à pleine marche ou à l'arrêt. Dans certaines grosses installations, on prévoit plusieurs allures.

Spanish

Save record 19

Record 20 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
  • Ovens, Furnaces and Boilers (Heating)
DEF

The maximum firing rate of a burner or furnace.

CONT

Normally, boilers are compared based upon combustion efficiency at high fire. Since many burners running at high fire, are capable of the best performance allowed under State Code, we expected to find nearly identical combustion efficiency for both boilers at high fire.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Fours et chaudières (Chauffage)
CONT

Les essais requis sont les suivants : [...] chaudière équipée d'un ou plusieurs brûleur(s) modulant(s) : un essai à la puissance maximale d'utilisation, un essai à la puissance minimale d'utilisation et trois essais à allure intermédiaire, respectivement à environ 75 p.c., 50 p.c. et 25 p.c. de la plage de modulation.

OBS

Annexe 2000 au mazout [...] Réglage du débit maximum. Placer le bouton de réglage en position «6» et attendre 10 minutes. À cette allure, la flamme doit être jaune à la base et jaune à son sommet. Elle ne doit pas être fumeuse.

OBS

Sous réserve des exceptions prévues à l'article 8 du présent décret, l'exploitant d'une chaudière doit disposer des appareils de contrôle suivants, en état de bon fonctionnement : [...] un indicateur permettant d'estimer l'allure de fonctionnement, pour une chaudière dont la puissance nominale est supérieure à 400 kW et inférieure à 2 MW, un indicateur du débit de combustible ou de fluide caloporteur dans les autres cas; [...]

Spanish

Save record 20

Record 21 2000-04-28

English

Subject field(s)
  • Combustion and Fuels (Fireplaces)
  • Burners and Steamfitting
CONT

open damper purge. During prepurge, the damper opens to high fire position and the burner motor drives air through the combustion chamber to remove any potentially explosive fuel or fumes. The damper closes to low fire position for ignition trials, and opens again to high fire position for the run period. Flame safeguard controls providing this feature have only 1 terminal for firing rate switching; they do not provide modulation during the run period.

French

Domaine(s)
  • Combustion et combustibles (Foyers)
  • Fumisterie et brûleurs

Spanish

Save record 21

Record 22 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
CONT

modulating fire. Varying the firing rate as the load varies. This results in longer burner operation because the firing rate is lowered as temperature or pressure builds up toward the cutoff point. It decreases on-off operation and increases the efficiency of the system.

CONT

There are four widely used operating configurations for gas fired appliances : modulating fire, on-off, hi-low, and multi-stage firing. Modulating fire is accomplished by mechanically varying the size of the gas admittance opening of one or more special "modulating" gas valves. With the gas valve completely open the boiler fires at it's full fire rate. The unit is said to be at "full turndown" when it fires at it's lowest firing rate. The "turndown ratio" is the ratio of full fire rate to full turndown firing rate and is a function of boiler design. A turn down ratio of 5 : 1 would indicate that a boiler is capable of a full turndown firing rate of 20%(5 : 1(100% fire : 20% fire).

OBS

modulating control: a method of control capable of increasing or decreasing by increments a quantity according to deviation from the required value.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Les brûleurs de gaz à air soufflé Piroil sont fournis sous forme monobloc, précâblés et prêts pour le fonctionnement. Construits pour une puissance thermique de 30.000 à 2.5000.000 Kcal/h dans les versions suivantes: une allure, deux allures, progressifs [...] Fonctionnement. Le cycle de travail prévoit au démarrage une période de prébalayage de la chambre de combustion avec le clapet d'air complètement ouvert, et obtenue à l'aide du servomoteur. Durant cette période l'éléctrovanne est fermée. À la fin de cette phase, avec le clapet d'air et le manchon gaz positionnés à une valeur minimale par le servomoteur, l'électrovanne gaz est excitée et le transformateur pourvoit à l'allumage du gaz au débit minimum. À ce moment, après avoir obtenu le consentement de présence de flamme par l'électrode d'ionisation, la boîte de contrôle met en marche le servomoteur air-gaz qui porte le brûleur, progressivement, dans un délai préétabli, à sa puissance maximale. Le brûleur reste en ces conditions de travail jusqu'à atteindre la température maximale, après cela, toujours thermostatiquement, à l'aide du servomoteur, on stabilise la puissance à un régime minimal, jusqu'à la demande de chaleur par la chaudière, qui peut être réétablie avec une modulation successive, sans pourtant interrompre complètement le fonctionnement.

OBS

régulation modulante : mode de régulation opérant par action de faible amplitude autour de la valeur désirée.

Spanish

Save record 22

Record 23 2000-04-28

English

Subject field(s)
  • Burners and Steamfitting
  • Ovens, Furnaces and Boilers (Heating)
DEF

The minimum firing rate of a burner or furnace.

OBS

See record "high fire / puissance maximale d’utilisation."

French

Domaine(s)
  • Fumisterie et brûleurs
  • Fours et chaudières (Chauffage)
OBS

Voir la fiche «puissance maximale d'utilisation / high fire».

Spanish

Save record 23

Record 24 2000-03-31

English

Subject field(s)
  • Burners and Steamfitting
  • Electric Motors
DEF

A modulating or a two-position(open-closed) motor which positions the firing rate valve and/or the damper in response to the firing rate controller.

OBS

See record "firing rate controller/régulateur d’allure de chauffe. "

French

Domaine(s)
  • Fumisterie et brûleurs
  • Moteurs électriques
OBS

Voir la fiche «régulateur d'allure de chauffe / firing rate controller».

Spanish

Save record 24

Record 25 2000-03-31

English

Subject field(s)
  • Burners and Steamfitting
DEF

A power burner in which a fan, or blower, blows air at high velocity past turbulators. The gas, at regulated pressure, is released into the turbulent airstream-typically from a ring at the mouth of the burner(in which case it is also called a ring burner). The gas escapes through orifices around the periphery of the ring. Gas and air are adjusted simultaneously to maintain the proper air-fuel ratio as the firing rate changes. In high-pressure gun burners, the gas is ejected at pressures up to 15 psi from spuds located in the center of the turbulent airstream instead of at the outside.

French

Domaine(s)
  • Fumisterie et brûleurs

Spanish

Save record 25

Record 26 2000-03-31

English

Subject field(s)
  • Burners and Steamfitting
CONT

gun type burner. A power burner in which a fan, or blower, blows air at high velocity past turbulators. The gas, at regulated pressure, is released into the turbulent airstream-typically from a ring at the mouth of the burner(in which case it is also called a ring burner). The gas escapes through orifices around the periphery of the ring. Gas and air are adjusted simultaneously to maintain the proper air-fuel ratio as the firing rate changes. In high-pressure gun burners, the gas is ejected at pressures up to 15 psi from spuds located in the center of the turbulent airstream instead of at the outside.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

gun burner / brûleur à air total.

Spanish

Save record 26

Record 27 2000-03-31

English

Subject field(s)
  • Electrical Circuits and Circuit Breakers
  • Heating
DEF

A circuit in a programming control which switches external devices at predetermined times to control the firing rate of the burner.

French

Domaine(s)
  • Circuits électriques et coupe-circuits
  • Chauffage
OBS

circuit de commutation / switching circuit.

OBS

Voir la fiche «régulateur d'allure de chauffe / firing rate controller».

Spanish

Save record 27

Record 28 2000-03-31

English

Subject field(s)
  • Burners and Steamfitting
DEF

Provision in a burner for either of 2 firing rates, high or low(no rate in between), selected according to load demand by the firing rate controller. A system is normally wired for guaranteed low fire start.

CONT

Control Valve. Interlocked one lever operation to correctly sequence Vent/Isolate - Available conditions. Self seal couplings prevent spillage during installation and removal of injector. Integral control of Fire/Recirculation and High-Low fire.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Les essais requis sont les suivants : chaudière équipée d'un ou plusieurs brûleurs «à tout ou rien», ou «à tout ou peu», la fonction «peu» étant une phase transitoire du démarrage du brûleur : un essai en période de fonctionnement continu du (des) brûleurs(s); chaudière équipée d'un ou plusieurs brûleur(s) à «tout ou peu», la fonction «peu» n'étant pas une phase transitoire du démarrage du (des) brûleur(s) : un essai à la puissance maximale d'utilisation du (des) brûleur(s) et un essai à la puissance minimale d'utilisation du (des) brûleur(s); [...]

OBS

Voir la fiche «allure maximale / high fire»

Spanish

Save record 28

Record 29 2000-03-31

English

Subject field(s)
  • Burners and Steamfitting
DEF

The set of equipment used to provide safe control of burner operation. This usually includes the flame safeguard control, the flame detection system, all controllers, all limits and interlocks, all fuel valves, the ignition system, the firing rate control system, and any other auxiliary equipment.

French

Domaine(s)
  • Fumisterie et brûleurs
CONT

Honeywell fabrique depuis longtemps un ensemble de dispositifs de commande et de sécurité pour brûleurs industriels et commerciaux connu parmi sa clientèle sous le nom de flame safeguard control system; flame safeguard system ou système de surveillance de flamme. [...] Les ensembles du genre ont principalement pour fonction de détecter la présence d'une flamme satisfaisante et d'assurer le démarrage, l'état de régime et l'arrêt sécuritaires du brûleur. [...] Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation.

CONT

Tout appareil neuf utilisant du gaz doit être équipé d'un système de surveillance de la flamme (Zündsicherung) selon la norme ITM-EN 125 respectivement de la norme DIN 3360-2.

Spanish

Save record 29

Record 30 1993-01-14

English

Subject field(s)
  • Guns (Land Forces)

French

Domaine(s)
  • Canons (Forces terrestres)

Spanish

Save record 30

Record 31 1992-10-08

English

Subject field(s)
  • Muscles and Tendons
CONT

Recruitment and firing rate modulation of motor unit tension in a small muscle of the cat's foot.(Cited in PASCAL data base.)

French

Domaine(s)
  • Muscles et tendons
CONT

Analyse emg des réflexes cutanés des petits muscles de la main et des potentiels eeg provoqués. Diagnostic et pronostic chez le nouveau-né (...) (Cité dans la base de données PASCAL.)

Spanish

Save record 31

Record 32 1991-07-04

English

Subject field(s)
  • Weapon Systems

French

Domaine(s)
  • Systèmes d'armes

Spanish

Save record 32

Record 33 1991-03-19

English

Subject field(s)
  • Solid Fuel Heating
CONT

Coal can be burned more efficiently by a mechanical stoker than by hand firing because the stoker provides a uniform fuel feed rate, better distribution in the fuel bed and positive control of the air supplied for combustion.

CONT

Hand firing. There are many acceptable hand-firing methods. With highly volatile coals, the objective is to leave a suitable bed of glowing fuel to ignite the gases as they are driven off from the fresh coal charge .... But, ... with any hand-fired solid fuel, the fire is continuous and overtemperature conditions are difficult to control unless the fire is continually attended.

French

Domaine(s)
  • Chauffage aux combustibles solides
CONT

La chauffe à la main est une opération délicate et souvent pénible, exigeant une formation spéciale et de la pratique; elle est très utilement guidée par l'emploi d'appareils de contrôle de chauffe.

OBS

Chauffe : Opération consistant à produire par combustion la chaleur nécessaire à un chauffage industriel ou domestique et, plus particulièrement, à conduire cette combustion

Spanish

Save record 33

Record 34 1991-03-12

English

Subject field(s)
  • Burners and Steamfitting
DEF

A control which automatically regulates the firing rate at predetermined air-fuel ratio in accordance with load demand.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Au point de vue de réglage de la combustion, on peut classer les brûleurs en appareils à réglage manuel ou en appareils à réglage automatique.

Spanish

Save record 34

Record 35 1990-10-05

English

Subject field(s)
  • Burners and Steamfitting
DEF

A control, other than a safety control or interlock, to start or regulate burner firing according to load demand and to stop or regulate firing on satisfaction of demand or upon reaching normal temperature or pressure in the appliances being fired. Operating controls may also actuate auxiliary equipment.

OBS

Controls for automatic fuel-burning equipment.... The controls can be classified as operating controls, limit controls, and interlocks. Operating controls include such things as a primary sensor, secondary sensors, actuators, ignition system, firing rate controls, draft controls, and programmers.... Operating controls initiate the normal starting and stopping of the burner in response to the primary sensor acting through appropriate actuators. Secondary sensors, secondary actuators, and ignition system are all part of the operating controls systems.

French

Domaine(s)
  • Fumisterie et brûleurs
DEF

Appareils de réglage : Appareils commandant le fonctionnement d'un brûleur en fonction des variations de température (ou de pression) du fluide contrôlé.

Spanish

Save record 35

Record 36 1990-10-05

English

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
CONT

Oil burners may be classified in several ways : by application, type of atomizer, firing rate, etc.... Further breakdown is made by type of design and operation, such as pressure atomizing, air or steam atomizing....

CONT

[Gun-type low pressure burners.] The oil and primary air are mixed in the nozzle at low pressures by the process known as air atomization.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

Les brûleurs utilisés en chauffage sont de deux types principaux, suivant le mode de pulvérisation du mazout, pulvérisation mécanique et pulvérisation par l'air. (...) Brûleurs à pulvérisation par l'air. La pulvérisation est obtenue au moyen d'air fourni par un compresseur à une pression de l'ordre de quelques dixièmes de bar. Le mazout est amené au brûleur par une pompe doseuse, pompe volumétrique qui permet d'obtenir un débit constant malgré les variations de viscosité du combustible. L'air de pulvérisation ne constitue qu'une partie de l'air nécessaire à la combustion. Le surplus est fourni par un ventilateur.

Spanish

Save record 36

Record 37 1990-10-05

English

Subject field(s)
  • Burners and Steamfitting
  • Gas and Oil Heating
CONT

Oil burners may be classified in several ways : by application, type of atomizer, firing rate, etc.... Further breakdown is made by type of design and operation, such as pressure atomizing, air or steam atomizing....

French

Domaine(s)
  • Fumisterie et brûleurs
  • Chauffage au gaz et au mazout
CONT

Pulvérisation par la vapeur. Les brûleurs qui utilisent la vapeur comme agent de pulvérisation sont habituellement capables de débits compris entre 5 et 2000 Kg/h.

Spanish

Save record 37

Record 38 1990-10-02

English

Subject field(s)
  • Burners and Steamfitting
  • Safety Devices (Mechanical Components)
DEF

A flame safeguard control which turns the burner on or off but does not vary the firing rate. Example : R4140M.

French

Domaine(s)
  • Fumisterie et brûleurs
  • Organes de sécurité (Composants mécaniques)
OBS

Le réglage peut s'effectuer manuellement ou automatiquement. [...] Réglage automatique [...] s'effectue [...] par l'un des procédés ci-après, [...] réglage par tout ou rien qui s'opère par une succession de périodes de marche au débit maximal et d'arrêt (cas particulier du tout ou peu avec débit minimal nul) [...].

Spanish

Save record 38

Record 39 1990-09-07

English

Subject field(s)
  • Outfitting of Ships
  • Propulsion of Water-Craft

French

Domaine(s)
  • Armement et gréement
  • Propulsion des bateaux

Spanish

Save record 39

Record 40 1990-06-12

English

Subject field(s)
  • Burners and Steamfitting
CONT

Return Flow Mechanical Atomizing Oil Burners. This [commercial-industrial oil] burner is a modification of a mechanical atomizing burner; atomization is accomplished by oil pressure alone.... The burner was developed for use in large installations such as on shipboard and in electric generating stations.... It is also used for firing large hot water boilers compressed air is too expensive for atomizing oil in large burners.... Wide range is accomplished by use of a return-flow nozzle which has a swirl chamber just ahead of the orifice or sprayer plate. Good atomization is attained by maintaining a high rate of oil flow and high pressure drop through the swirl chamber. The excess oil above the load demand is returned from the swirl chamber to the oil storage tank or to the oil pump suction. Control of burning rate is accomplished by varying the oil pressure in both the oil inlet and the oil return lines.

OBS

This is a register-type burner similar to the mechanical atomizing burners.

French

Domaine(s)
  • Fumisterie et brûleurs
OBS

Pulvérisation mécanique à retour. Dans le but d'obtenir une plage de réglage suffisante, le pulvérisateur mécanique est complété d'un circuit de retour qui ramène au réservoir une partie du combustible prélevé dans le pulvérisateur même.

Spanish

Save record 40

Record 41 1990-01-08

English

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Oil furnaces. Indoor oil furnaces... are available in upflow, downflow, horizontal and low-boy configurations for ducted systems. They are also available as floor furnaces, wall furnaces, and free standing space heaters. Oil-fired outdoor furnaces and combination units are rare.... The ducted system, oil-fired, forced air furnaces are usually equipped with pressure-atomizing burners. The pump pressure and the orifice size of the injection nozzle regulate the firing rate of the furnace. Electric ignition is used to ignite the burners.... The combustion chamber and heat exchanger of oil-fired furnaces are normally formed as a common single chamber. It is formed from heavy gage steel into a welded assembly. The hot flue products flow through the inside of the heat exchanger into the chimney. The conditioned air flows over the outside of the heat exchanger and into the air supply plenum.

French

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Maison de fin de semaine (...) On peut prévoir aussi le chauffage par air chaud avec générateur à mazout ou à gaz et distributions par gaines.

OBS

Fournaise : Ce terme est considéré comme impropre par les puristes. Selon Dagenais, dans son "Dictionnaire des difficultés de la langue française au Canada", "fournaise" serait un calque de l'anglais "furnace" et nous devrions plutôt dire "chaudière" lorsque le fluide caloporteur est l'eau ou la vapeur et "générateur d'air chaud", lorsque le fluide, est l'air. Cependant, ce terme reste d'usage fréquent au Québec, autant en langue parlée qu'en langue écrite.

Spanish

Save record 41

Record 42 1987-03-19

English

Subject field(s)
  • Weapon Systems
  • Missiles and Rockets
CONT

The K3S automatic launching system, specially designed by MBB for this vehicle, is fully NBC protected and has a firing rate of almost 3 rounds/min.

French

Domaine(s)
  • Systèmes d'armes
  • Missiles et roquettes
CONT

L'affût de lancement automatique K3S, spécialement réalisé pour le Raketenjagdpanzer par MBB, est entièrement étanche aux agents NBC et permet une cadence de tir de près de 3 coups/mn.

Spanish

Save record 42

Record 43 1986-06-18

English

Subject field(s)
  • Control Instrumentation (Mechanical Components)
  • Burners and Steamfitting
DEF

A flame safeguard control that adds a timing function to the primary control to sequence additional burner functions such as prepurge, postpurge, timed trials for pilot and main burner flame, and firing rate switching.

Key term(s)
  • programing control
  • programer

French

Domaine(s)
  • Dispositifs de commande (Composants mécaniques)
  • Fumisterie et brûleurs
CONT

Le système de surveillance de flamme englobe tout l'appareillage de commande et de sécurité, ainsi que les éléments annexes nécessaires au bon fonctionnement et à la sécurité d'emploi du brûleur dans les conditions prévues d'utilisation. Il comprend donc : (...) un programmateur [qui permet] de programmer la séquence de fonctionnement du brûleur et de l'équipement qui lui est asservi (vannes, ventilateur, etc.).

Spanish

Save record 43

Record 44 1985-05-01

English

Subject field(s)
  • Blasting Work (Mining)
  • Explosives and Pyrotechnical Materials (Industries)
DEF

A train of powder enclosed in cotton, jute yarn, and waterproofing compounds; used for firing a cap containing the detonating compound which in turn sets off the explosive charge. The fuse burns at the rate of 2 feet per minute.

OBS

To avoid repeating the complete terms "safety fuse" and "blasting fuse" in a long text, authors often shorten them to "fuse".

French

Domaine(s)
  • Travail aux explosifs (Exploitation minière)
  • Explosifs et artifices (Industries)
DEF

(...) artifice constitué par un cordon de pulvérin (poudre noire en grains fins) contenu dans une gaine de coton tressé goudronnée, utilisé pour allumer le détonateur d'une charge d'explosif ou allumer directement une cartouche de poudre noire ou un explosif à oxygène liquide. (...) La mèche de sûreté brûle à une vitesse très régulière, voisine de 1 cm/s.

OBS

Le mot "mèche" est souvent employé pour remplacer "mèche de mineur", "mèche de sûreté", et "mèche lente" afin d'éviter la répétition du terme au complet dans un long texte.

OBS

«mèche de mineur» : normalisé par l'AFNOR.

Spanish

Save record 44

Record 45 1984-11-01

English

Subject field(s)
  • Weapon Systems

French

Domaine(s)
  • Systèmes d'armes

Spanish

Save record 45

Record 46 1984-10-23

English

Subject field(s)
  • Fire Safety

French

Domaine(s)
  • Sécurité incendie

Spanish

Save record 46

Record 47 1982-11-17

English

Subject field(s)
  • Shipbuilding

French

Domaine(s)
  • Constructions navales

Spanish

Save record 47

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: