GAMMA IRRADIATOR [7 records]
Record 1 - internal organization data 2012-02-17
Record 1, English
Record 1, Subject field(s)
- Tomography
Record 1, Main entry term, English
- detection
1, record 1, English, detection
correct
Record 1, Abbreviations, English
Record 1, Synonyms, English
Record 1, Textual support, English
Record number: 1, Textual support number: 1 CONT
The [Compton scatter tomography] system incorporates a conventional scintillation camera and its dedicated minicomputer together with a specially designed gamma irradiator. This system for the detection of Compton scatter with a scintillation camera has been previously presented by the authors.(Medical Radionuclide Imaging, 1977, vol. 1, p. 255). 1, record 1, English, - detection
Record 1, French
Record 1, Domaine(s)
- Tomographie
Record 1, Main entry term, French
- détection
1, record 1, French, d%C3%A9tection
correct, feminine noun
Record 1, Abbreviations, French
Record 1, Synonyms, French
Record 1, Textual support, French
Record number: 1, Textual support number: 1 DEF
Fonction des détecteurs. 1, record 1, French, - d%C3%A9tection
Record 1, Spanish
Record 1, Textual support, Spanish
Record 2 - internal organization data 2005-10-28
Record 2, English
Record 2, Subject field(s)
- Scientific Instruments
- Radiological Physics (Theory and Application)
- Food Preservation and Canning
Record 2, Main entry term, English
- gamma irradiator 1, record 2, English, gamma%20irradiator
Record 2, Abbreviations, English
Record 2, Synonyms, English
Record 2, Textual support, English
Record 2, French
Record 2, Domaine(s)
- Instruments scientifiques
- Physique radiologique et applications
- Conservation des aliments et conserverie
Record 2, Main entry term, French
- ionisateur gamma
1, record 2, French, ionisateur%20gamma
correct, masculine noun
Record 2, Abbreviations, French
Record 2, Synonyms, French
- irradiateur gamma 1, record 2, French, irradiateur%20gamma
correct, masculine noun
Record 2, Textual support, French
Record number: 2, Textual support number: 1 DEF
Ionisateur dont la source de rayonnement est constituée d'un radio-isotope. 1, record 2, French, - ionisateur%20gamma
Record number: 2, Textual support number: 1 OBS
En agroalimentaire, les radio-isotopes autorisés sont le cobalt 60 et le césium 137. 1, record 2, French, - ionisateur%20gamma
Record 2, Spanish
Record 2, Campo(s) temático(s)
- Instrumentos científicos
- Física radiológica (Teoría y aplicación)
- Conservación de los alimentos y elaboración de conservas
Record 2, Main entry term, Spanish
- ionizador de rayos gamma
1, record 2, Spanish, ionizador%20de%20rayos%20gamma
masculine noun
Record 2, Abbreviations, Spanish
Record 2, Synonyms, Spanish
- irradiador gamma 1, record 2, Spanish, irradiador%20gamma
masculine noun, Cuba, Mexico
Record 2, Textual support, Spanish
Record 3 - internal organization data 2003-05-26
Record 3, English
Record 3, Subject field(s)
- Equipment (Chemistry)
- Medical Instruments and Devices
- Blood
Record 3, Main entry term, English
- blood irradiator
1, record 3, English, blood%20irradiator
correct
Record 3, Abbreviations, English
Record 3, Synonyms, English
Record 3, Textual support, English
Record number: 3, Textual support number: 1 CONT
Blood irradiator BI-2000. Applications : Irradiation of blood & blood products by gamma rays is a proven and safe method to inhibit T-Lymphocyte proliferation and eliminate the risk of post transfusion graft versus host disease(T-GVHD). Gamma irradiation of cellular blood components is the best current technology to reduce the risk of T-GVHD to the recipients as confirmed by research and therefore being widely practiced world over in hospitals and blood banks as a life saving approach to this problem. Blood is usually irradiated in standard blood bags in dedicated blood irradiators using cobalt-60 or caesium-137 radioactive source. The usual recommended radiation doses are 25 Gy to 35 Gy(1 Gy=100 rad) for this purposes. 2, record 3, English, - blood%20irradiator
Record 3, French
Record 3, Domaine(s)
- Équipement (Chimie)
- Instruments et appareillages médicaux
- Sang
Record 3, Main entry term, French
- irradiateur sanguin
1, record 3, French, irradiateur%20sanguin
proposal, masculine noun
Record 3, Abbreviations, French
Record 3, Synonyms, French
Record 3, Textual support, French
Record number: 3, Textual support number: 1 OBS
L'établissement de transfusion sanguine de Lyon conformément à la loi du 19 juillet 1976 modifiée, relative aux Installations Classées pour la protection de l'environnement, sollicite l'autorisation d'exploiter un irradiateur de produits sanguins dans son antenne située dans l'enceinte de l'Hôpital Édouard Herriot à Lyon 3e. 2, record 3, French, - irradiateur%20sanguin
Record 3, Spanish
Record 3, Textual support, Spanish
Record 4 - internal organization data 2003-05-26
Record 4, English
Record 4, Subject field(s)
- Equipment (Chemistry)
- Medical Instruments and Devices
- Blood
Record 4, Main entry term, English
- blood irridiator canister
1, record 4, English, blood%20irridiator%20canister
correct
Record 4, Abbreviations, English
Record 4, Synonyms, English
- irradiation canister 2, record 4, English, irradiation%20canister
correct
- canister of irradiation 3, record 4, English, canister%20of%20irradiation
correct
- canister 2, record 4, English, canister
correct
Record 4, Textual support, English
Record number: 4, Textual support number: 1 CONT
The ISP Dose-Map [registered trade name] Dosimetry System for blood irradiators is based on an instant-imaging film medium that darkens in response of ionizing radiation. The film has been extensively characterized and calibrated at the National Institute of Standards and Technology (NIST) and is capable of measuring the absorbed dose in a blood irradiator canister at an accuracy on the order of ± 5%. 1, record 4, English, - blood%20irridiator%20canister
Record number: 4, Textual support number: 2 CONT
Irradiation of whole blood and blood components.... A minimum of 25 Gy of gamma irradiation must be delivered, targeted to the midplane of the canister when using a free-standing irradiator, or targeted to the central midplane of the field of irradiation when using a radiotherapy instrument. 15 Gy must be the minimum dose at any location in the canister or field of irradiation and the maximum dose must not exceed 50 Gy. 3, record 4, English, - blood%20irridiator%20canister
Record 4, French
Record 4, Domaine(s)
- Équipement (Chimie)
- Instruments et appareillages médicaux
- Sang
Record 4, Main entry term, French
- cellule d'irradiation
1, record 4, French, cellule%20d%27irradiation
correct, feminine noun
Record 4, Abbreviations, French
Record 4, Synonyms, French
- cellule 1, record 4, French, cellule
correct, feminine noun
Record 4, Textual support, French
Record number: 4, Textual support number: 1 CONT
Irradiation du sang total et des composants sanguins. [...] La dose minimale de rayonnement gamma, qui est de 25 Gy, doit être dirigée vers le plan moyen de la cellule, lorsqu'on utilise un irradiateur portable ou le plan moyen central du champ d'irradiation, lorsqu'on utilise un appareil de radiothérapie. En tout point de la cellule ou du champ d'irradiation, la dose minimale doit être de 15 Gy. La dose maximale ne doit pas dépasser 50 Gy. 1, record 4, French, - cellule%20d%27irradiation
Record 4, Spanish
Record 4, Textual support, Spanish
Record 5 - internal organization data 2003-05-26
Record 5, English
Record 5, Subject field(s)
- Blood
Record 5, Main entry term, English
- irradiation of whole blood
1, record 5, English, irradiation%20of%20whole%20blood
correct
Record 5, Abbreviations, English
Record 5, Synonyms, English
- whole blood irradiation 2, record 5, English, whole%20blood%20irradiation
correct
Record 5, Textual support, English
Record number: 5, Textual support number: 1 CONT
Irradiation of whole blood and blood components.... A minimum of 25 Gy of gamma irradiation must be delivered, targeted to the midplane of the canister when using a free-standing irradiator, or targeted to the central midplane of the field of irradiation when using a radiotherapy instrument. 15 Gy must be the minimum dose at any location in the canister or field of irradiation and the maximum dose must not exceed 50 Gy. 1, record 5, English, - irradiation%20of%20whole%20blood
Record 5, French
Record 5, Domaine(s)
- Sang
Record 5, Main entry term, French
- irradiation du sang total
1, record 5, French, irradiation%20du%20sang%20total
correct, feminine noun
Record 5, Abbreviations, French
Record 5, Synonyms, French
Record 5, Textual support, French
Record number: 5, Textual support number: 1 CONT
Irradiation du sang total et des composants sanguins. [...] La dose minimale de rayonnement gamma, qui est de 25 Gy, doit être dirigée vers le plan moyen de la cellule, lorsqu'on utilise un irradiateur portable ou le plan moyen central du champ d'irradiation, lorsqu'on utilise un appareil de radiothérapie. En tout point de la cellule ou du champ d'irradiation, la dose minimale doit être de 15 Gy. La dose maximale ne doit pas dépasser 50 Gy. 1, record 5, French, - irradiation%20du%20sang%20total
Record number: 5, Textual support number: 1 OBS
irradiation : Procédé consistant à irradier les composants sanguins avec un rayonnement gamma d'une intensité de 25 Gy ciblé sur le plan moyen ou moyen central de la cellule ou du champ d'irradiation. 1, record 5, French, - irradiation%20du%20sang%20total
Record 5, Spanish
Record 5, Textual support, Spanish
Record 6 - internal organization data 2003-05-26
Record 6, English
Record 6, Subject field(s)
- Equipment (Chemistry)
- Medical Instruments and Devices
- Blood
Record 6, Main entry term, English
- free-standing irradiator
1, record 6, English, free%2Dstanding%20irradiator
correct
Record 6, Abbreviations, English
Record 6, Synonyms, English
Record 6, Textual support, English
Record number: 6, Textual support number: 1 CONT
Irradiation of whole blood and blood components. Cellular components such as : Red blood cells; Platelets; Platelets-Pheresis, and Granulocytes-Pheresis, should be irradiated for prophylaxis of transfusion-associated graft versus host disease(TA-GVHD) in recipients at risk. A minimum of 25 Gy of gamma irradiation must be delivered, targeted to the midplane of the canister when using a free-standing irradiator, or targeted to the central midplane of the field of irradiation when using a radiotherapy instrument. 15 Gy must be the minimum dose at any location in the canister or field of irradiation and the maximum dose must not exceed 50 Gy. 1, record 6, English, - free%2Dstanding%20irradiator
Record 6, French
Record 6, Domaine(s)
- Équipement (Chimie)
- Instruments et appareillages médicaux
- Sang
Record 6, Main entry term, French
- irradiateur portable
1, record 6, French, irradiateur%20portable
correct, masculine noun
Record 6, Abbreviations, French
Record 6, Synonyms, French
Record 6, Textual support, French
Record number: 6, Textual support number: 1 CONT
Irradiation du sang total et des composants sanguins. Chez les patients à risque, les composants cellulaires tels que les globules rouges, les plaquettes, les plaquettes d'aphérèse et les granulocytes d'aphérèse devraient être irradiés afin de prévenir une réaction du greffon contre l'hôte. La dose minimale de rayonnement gamma, qui est de 25 Gy, doit être dirigée vers le plan moyen de la cellule, lorsqu'on utilise un irradiateur portable ou le plan moyen central du champ d'irradiation, lorsqu'on utilise un appareil de radiothérapie. En tout point de la cellule ou du champ d'irradiation, la dose minimale doit être de 15 Gy. La dose maximale ne doit pas dépasser 50 Gy. 1, record 6, French, - irradiateur%20portable
Record number: 6, Textual support number: 1 OBS
irradiation : Procédé consistant à irradier les composants sanguins avec un rayonnement gamma d'une intensité de 25 Gy ciblé sur le plan moyen ou moyen central de la cellule ou du champ d'irradiation. 1, record 6, French, - irradiateur%20portable
Record 6, Spanish
Record 6, Textual support, Spanish
Record 7 - internal organization data 2003-05-26
Record 7, English
Record 7, Subject field(s)
- Blood
Record 7, Main entry term, English
- irradiation of blood components
1, record 7, English, irradiation%20of%20blood%20components
correct
Record 7, Abbreviations, English
Record 7, Synonyms, English
- blood component irradiation 2, record 7, English, blood%20component%20irradiation
correct
Record 7, Textual support, English
Record number: 7, Textual support number: 1 CONT
Irradiation of whole blood and blood components. Cellular components such as : Red blood cells; Platelets; Platelets-Pheresis, and Granulocytes-Pheresis, should be irradiated for prophylaxis of transfusion-associated graft versus host disease(TA-GVHD) in recipients at risk. A minimum of 25 Gy of gamma irradiation must be delivered, targeted to the midplane of the canister when using a free-standing irradiator, or targeted to the central midplane of the field of irradiation when using a radiotherapy instrument. 15 Gy must be the minimum dose at any location in the canister or field of irradiation and the maximum dose must not exceed 50 Gy. 1, record 7, English, - irradiation%20of%20blood%20components
Record 7, French
Record 7, Domaine(s)
- Sang
Record 7, Main entry term, French
- irradiation des composants sanguins
1, record 7, French, irradiation%20des%20composants%20sanguins
correct, feminine noun
Record 7, Abbreviations, French
Record 7, Synonyms, French
Record 7, Textual support, French
Record number: 7, Textual support number: 1 CONT
Irradiation du sang total et des composants sanguins. Chez les patients à risque, les composants cellulaires tels que les globules rouges, les plaquettes, les plaquettes d'aphérèse et les granulocytes d'aphérèse devraient être irradiés afin de prévenir une réaction du greffon contre l'hôte. La dose minimale de rayonnement gamma, qui est de 25 Gy, doit être dirigée vers le plan moyen de la cellule, lorsqu'on utilise un irradiateur portable ou le plan moyen central du champ d'irradiation, lorsqu'on utilise un appareil de radiothérapie. En tout point de la cellule ou du champ d'irradiation, la dose minimale doit être de 15 Gy. La dose maximale ne doit pas dépasser 50 Gy. 1, record 7, French, - irradiation%20des%20composants%20sanguins
Record number: 7, Textual support number: 1 OBS
irradiation : Procédé consistant à irradier les composants sanguins avec un rayonnement gamma d'une intensité de 25 Gy ciblé sur le plan moyen ou moyen central de la cellule ou du champ d'irradiation. 1, record 7, French, - irradiation%20des%20composants%20sanguins
Record 7, Spanish
Record 7, Textual support, Spanish
Copyright notice for the TERMIUM Plus® data bank
© Public Services and Procurement Canada, 2025
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau
Features
Language Portal of Canada

Access a collection of Canadian resources on all aspects of English and French, including quizzes.
Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.
Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.
- Date Modified: