TERMIUM Plus®

From: Translation Bureau

On social media

Consult the Government of Canada’s terminology data bank.

HEAT SUPPLY SYSTEM [28 records]

Record 1 2024-07-31

English

Subject field(s)
  • Food Safety
  • Hygiene and Health
CONT

Water safety at the community level involves interventions at the source of the water supply or in the distribution system, including physically removing pathogens(i. e., through filtration, adsorption, sedimentation, or other methods) ;chemically treating the water, commonly with chlorine, to kill or deactivate pathogens; and disinfecting water using heat(i. e., boiling or pasteurization) or ultraviolet radiation(i. e., sun or artificial lamp). Alternatively, protected sources of water can be created, such as springs, wells, and boreholes, which are generally free from contaminants. As for sanitation, improved and unimproved water facilities have been defined based on their risk of contamination.

French

Domaine(s)
  • Salubrité alimentaire
  • Hygiène et santé

Spanish

Campo(s) temático(s)
  • Inocuidad Alimentaria
  • Higiene y Salud
CONT

La salubridad del agua se evalúa empleando un enfoque de valoración del riesgo, como la planificación de la salubridad del agua, y podrá incluir inspecciones sanitarias.

Save record 1

Record 2 2019-12-18

English

Subject field(s)
  • Heating
  • Solar Energy
  • Modern Construction Methods
DEF

The heat storage of a solar heating system that is able to supply heat for only a few days.

French

Domaine(s)
  • Chauffage
  • Énergie solaire
  • Procédés de construction modernes

Spanish

Campo(s) temático(s)
  • Calefacción
  • Energía solar
  • Métodos de construcción modernos
Save record 2

Record 3 2010-11-02

English

Subject field(s)
  • Security Devices
  • Fire Warning Devices
CONT

The building has the following safety features : Two stage fire alarm system, emergency voice communication system, emergency power supply, pull stations, crossover floors, fire fighter service elevators, automatic sprinkler systems, heat and smoke detectors, emergency lighting, Exit signs, standpipe and hose cabinets, fire extinguishers and an emergency organization.

Key term(s)
  • emergency voice communications system

French

Domaine(s)
  • Dispositifs de sécurité
  • Alarme-incendie
CONT

L’immeuble possède les dispositifs de sécurité suivants : réseau avertisseur d’incendie à double signal, système de communication vocale d’urgence, alimentation électrique d’urgence, avertisseurs d’incendie, étages de communication, ascenseurs pour pompiers, gicleurs automatiques, détecteurs de chaleur et de fumée, éclairage de secours, signaux de sortie, armoires à lance d’incendie, extincteurs et organisation des secours en cas d’incendie et d’urgence.

Spanish

Save record 3

Record 4 2010-05-27

English

Subject field(s)
  • Heating
OBS

Heating in which water having supply temperature between 250°F(112°C) and 350°F(177°C) is used as a medium to convey heat from a central boiler, through a piping system, to suitable heat-distributing devices.

French

Domaine(s)
  • Chauffage
OBS

Chauffage à eau chaude à haute température (eau surpressée dite surchauffée ou sous saturée). Ce système de chauffage utilise de l'eau à une température supérieure à 100 °C, en général on ne descend pas en dessous de 120 °C, et on ne monte pas au-dessus de 200 °C, donc à une pression supérieure à la pression atmosphérique pour éviter les vaporisations.

OBS

eau surchauffée: Eau portée à une température supérieure à 100 °C, ne se vaporisant pas grâce à un maintien sous pression adéquate (supérieure à la pression d'ébullition correspondant à la température de l'eau).

OBS

Il semblerait que la notion de chauffage à eau surchauffée englobe celle des termes «medium-» et «high temperature water heating».

Spanish

Save record 4

Record 5 2010-05-27

English

Subject field(s)
  • Heating
OBS

Heating in which water having supply temperatures above 350°F(177°C) is used as a medium to convey heat from a central boiler, through a piping system, to suitable heat distributing means.

French

Domaine(s)
  • Chauffage
OBS

Chauffage à eau chaude à haute température (eau surpressée dite surchauffée ou sous saturée). Ce système de chauffage utilise de l'eau à une température supérieure à 100 °C, en général on ne descend pas en dessous de 120 °C, et on ne monte pas au-dessus de 200 °C, donc à une pression supérieure à la pression atmosphérique pour éviter les vaporisations.

OBS

eau surchauffée: eau portée à une température supérieure à 100 °C, ne se vaporisant pas grâce à un maintien sous pression adéquate (supérieure à la pression d'ébullition correspondant à la température de l'eau).

OBS

Il semblerait que la notion de chauffage à eau surchauffée englobe celle des termes «medium-» et «high-temperature water heating».

Spanish

Save record 5

Record 6 2010-05-27

English

Subject field(s)
  • Heating
DEF

A heating system in which water having supply temperatures above 350°F(177°C) is used as a medium to convey heat from a central boiler, through a piping system, to suitable heat distributing means.

OBS

High-temperature water systems are those that supply water for heating at temperatures above 250°F and at pressures from 65 to 350 psig.

Key term(s)
  • high temperature hot water heating system

French

Domaine(s)
  • Chauffage
OBS

Chauffage à eau chaude à haute température (eau surpressée dite surchauffée ou sous saturée). [...] l'eau [est] à une température supérieure à 100 °C (212 °F) (en général on ne descend pas en dessous de 120°C (248 °F) et on ne monte pas au-dessus de 200 °C (392 °F).

OBS

L'eau chaude à haute température, au-dessus de 100 °C, donc nécessairement à une pression supérieure à celle de l'atmosphère, dite pour cette raison «à haute pression» et aussi, à tort, «surchauffée», n'est employée directement que pour le chauffage de locaux industriels.

OBS

Eau surchauffée, eau portée à une température supérieure à 100 °C, ne se vaporisant pas grâce à un maintien sous pression adéquate (supérieure à la pression d'ébullition correspondant à la température de l'eau).

OBS

Le domaine couvert par la notion française de chauffage à eau chaude à haute température (ou à eau surchauffée) englobe les deux notions anglaises de «medium temperature water heating» (250 à 350 degrés F) et «high temperature water heating» (350 degrés F et plus).

Spanish

Save record 6

Record 7 2010-02-09

English

Subject field(s)
  • Fixed Rescue Facilities (fire)
CONT

A fire sprinkler system shall be provided that will automatically shut-off the water supply flow control valve when the fires heat source has been controlled and a soak timer has expired. If the fires heat source was to regenerate, the fire sprinkler system shall automatically reopen. This cycling feature of the sprinkler system shall not be dependent on manual supervision. Cycling fire sprinkler system shall be a closed head type of preaction system with a supplemental detection system which will activate flow control valve.

CONT

Cycling sprinkler. A development by the sprinkler industry is a sprinkler that cycles on and off as needed.... Under normal conditions, the pilot valve is held closed by the snap disc. Water in the piston chamber holds the piston closed. When the snap disc is heated to the rated temperature, it opens the pilot valve and releases the water from the piston chamber. This allows the piston to open and water to flow from the sprinkler. When the snap disc cools to approximately 100°F, it closes the pilot valve.

OBS

"Flow Control" sprinklers are a product of Central Sprinkler Corporation.

Key term(s)
  • cycling type sprinkler
  • cycling type fire sprinkler

French

Domaine(s)
  • Installations fixes de secours (incendies)
CONT

Sprinkleurs spéciaux [...] sprinkleurs «on/off» dont l'obturateur peut s'ouvrir et se refermer suivant la température sous l'action d'un bilame, utiles pour réduire l'arrosage au minimum.

Spanish

Save record 7

Record 8 2009-10-29

English

Subject field(s)
  • Water Supply
  • Nuclear Fission Reactors
CONT

Emergency Feedwater(EFW) System. The emergency heat removal function is accomplished by the EFW system. The system provides an independent supply of feedwater to the steam generators to remove decay and sensible heat to cool down the reactor following a total loss of the main and emergency feedwater systems.

French

Domaine(s)
  • Alimentation en eau
  • Réacteurs nucléaires de fission
CONT

Circuit d'eau d'alimentation d'urgence (SEU). La fonction de refroidissement d'urgence est accomplie par le circuit SEU. Le circuit approvisionne indépendamment les générateurs de vapeur en eau d'alimentation pour éliminer la chaleur de désintégration et sensible afin de refroidir le réacteur après une perte totale des circuits d'eau d'alimentation principaux et d'urgence.

Spanish

Save record 8

Record 9 - external organization data 2006-01-25

English

Subject field(s)
  • Mechanical Components
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

State the function and basic principle of operation of the HTS [heat transport system] pump gland and gland seal supply system. The HTS [heat transport system] pump gland and gland seal supply system protect the pump seals and bearings from damage. They also prevent leakage of radioactive coolant through the pump seals.

French

Domaine(s)
  • Composants mécaniques
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Expliquer la fonction et le principe de fonctionnement du joint d'étanchéité de la pompe du circuit caloporteur, ainsi que du système d'alimentation du joint d'étanchéité. La garniture de la pompe du CC [circuit caloporteur] et le système d'approvisionnement du joint d'étanchéité protègent les joints de pompe et les paliers contre les dommages. Ils permettent également d'éviter qu'il y ait des fuites de caloporteur radioactif aux joints de pompe.

Spanish

Save record 9

Record 10 - external organization data 2005-12-21

English

Subject field(s)
  • Mechanical Components
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

State the function and basic principle of operation of the HTS [heat transport system] pump gland and gland seal supply system. The HTS [heat transport system] pump gland and gland seal supply system protect the pump seals and bearings from damage. They also prevent leakage of radioactive coolant through the pump seals.

French

Domaine(s)
  • Composants mécaniques
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Expliquer la fonction et le principe de fonctionnement du joint d'étanchéité de la pompe du circuit caloporteur, ainsi que du système d'alimentation du joint d'étanchéité. La garniture de la pompe du CC [circuit caloporteur] et le système d'approvisionnement du joint d'étanchéité protègent les joints de pompe et les paliers contre les dommages. Ils permettent également d'éviter qu'il y ait des fuites de caloporteur radioactif aux joints de pompe.

Spanish

Save record 10

Record 11 - external organization data 2005-11-10

English

Subject field(s)
  • Water Supply
  • Nuclear Fission Reactors
  • Compartment - Canadian Nuclear Safety Commission
CONT

The Low-pressure Service Water system(LPSW) provides a continuous flow of strained lake water for specific cooling purposes such as to seals, bearings, and heat exchangers. The temperature of the LPSW ranges from 2°C to 27°C. The LPSW draws its supply from the intake channel.

Key term(s)
  • low pressure service water system

French

Domaine(s)
  • Alimentation en eau
  • Réacteurs nucléaires de fission
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

Le circuit d'eau de service à basse pression (CESBP) assure l'écoulement continu de l'eau filtrée du lac pour le refroidissement d'éléments particuliers comme les joints, les paliers et les échangeurs de chaleur. La température de ce circuit varie de 2 à 27 °C. Ce circuit s'alimente au canal d'amenée.

Spanish

Save record 11

Record 12 - external organization data 2005-11-08

English

Subject field(s)
  • Electrical Power Supply
  • Nuclear Power Stations
  • Compartment - Canadian Nuclear Safety Commission
CONT

Class IV power supplies AC loads that can be interrupted indefinitely without affecting personnel or plant safety. Typical loads on a Class IV system are normal lighting and the primary heat transport pump motors. During normal operation, the UST [unit service transformer] carries the reactor unit loads. Should the need arise; the loads can be supplied fully by the SST [system service transformer]. Thus, the electrical grid system serves as an emergency power supply for the Class IV system.

French

Domaine(s)
  • Alimentation (Distribution électrique)
  • Centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
CONT

On peut déconnecter indéfiniment les charges raccordées à l'alimentation électrique de catégorie IV, sans affecter la sécurité du personnel ou la sûreté de la centrale. Sont raccordées au circuit de catégorie IV, des charges comme l'éclairage normal et les moteurs des pompes du circuit caloporteur. En condition normale d'exploitation, le transformateur d'alimentation du réacteur fournit l'énergie aux charges du réacteur. Au besoin, ces mêmes charges peuvent être complètement prises en charge par le transformateur d'alimentation des systèmes. En cas d'urgence, le réseau électrique prend la relève et alimente les charges raccordées au réseau de catégorie IV.

Spanish

Save record 12

Record 13 2004-02-25

English

Subject field(s)
  • Geological Research and Exploration
  • Energy Transformation
CONT

Hot dry rock process(petrophysical systems). Hot rock layers at a depth of 4, 000 to 7, 000 meters are used with this new system which has not yet been fully developed. Water is pressed into the hot rock via a borehole and the heated water is then fed back to the surface and used to supply heat or produce electricity.

CONT

In order to be able to gain heat from the deep, crystalline rockbeds, the so-called hot-dry-rock technique was developed.

French

Domaine(s)
  • Recherches et prospections géologiques
  • Transformation de l'énergie
DEF

[Technique dans laquelle] de l'eau froide est injectée dans un puits de 1 900 mètres de profondeur aboutissant dans un massif granitique où la température ambiante est d'environ 170 °C. L'eau est conduite par un réseau de fractures en pente jusqu'à un puits plus profond où les infiltrations sont pompées. La vapeur d'eau récupérée est à une température moyenne de 150 °C. Elle est alors traitée pour être distribuée dans les foyers avoisinants, à des fins de consommation courante [...]

Spanish

Save record 13

Record 14 2001-04-18

English

Subject field(s)
  • Textile Industries
  • Textiles: Preparation and Processing
  • Engineering Tests and Reliability
  • Strength of Materials
CONT

FWWMR: denotes textile fabrics which are Fire, Water, Weather and Mildew resistant.

CONT

The outer fabric, or skin of this tent, is a one-piece, preformed body manufactured from 9. 85 or 12. 29 ounce duck material which is fire, water, weather, and mildew resistant. These tents are designed for use in tropical or temperate zones, but with the installation of a liner and/or stove, may be used effectively in colder climates. The liner is also effective in reducing heat from midsummer sun. Liners are not normally issued with the tent, but are available through the supply system.

Key term(s)
  • F.W.W.M.R

French

Domaine(s)
  • Industries du textile
  • Apprêt et traitements divers (Textiles)
  • Fiabilité, contrôle et essais (Ingénierie)
  • Résistance des matériaux

Spanish

Campo(s) temático(s)
  • Industrias textiles
  • Preparación y elaboración (Textiles)
  • Fiabilidad y ensayos (Ingeniería)
  • Resistencia de los materiales
Save record 14

Record 15 2000-08-29

English

Subject field(s)
  • Steelmaking
CONT

... only the independent supply of the end flues makes it possible to integrate a heat regulation system designed to adapt the different heat demand throughout the course of a coking cycle for each oven.

French

Domaine(s)
  • Élaboration de l'acier

Spanish

Save record 15

Record 16 2000-08-29

English

Subject field(s)
  • Steelmaking
CONT

... only the independent supply of the end flues makes it possible to integrate a heat regulation system designed to adapt the different heat demand throughout the course of a coking cycle for each oven.

French

Domaine(s)
  • Élaboration de l'acier

Spanish

Save record 16

Record 17 - external organization data 2000-05-31

English

Subject field(s)
  • Nuclear Power Stations
  • Nuclear Plant Safety
  • Compartment - Canadian Nuclear Safety Commission
DEF

... a component that forms a part of a common service system, such as electrical power, water supply, instrument air, and back-up heat sinks, that is essential for the proper operation of the "special safety systems".

CONT

Safety-support systems are a category of process systems ...

French

Domaine(s)
  • Centrales nucléaires
  • Sûreté des centrales nucléaires
  • Tiroir - Commission canadienne de sûreté nucléaire
DEF

Composant d'un système de service commun, comme l'électricité, l'eau, l'air de régulation et les sources froides de réserve, indispensable au bon fonctionnement des systèmes spéciaux de sûreté.

Spanish

Save record 17

Record 18 1990-01-08

English

Subject field(s)
  • Ovens, Furnaces and Boilers (Heating)
CONT

Oil furnaces. Indoor oil furnaces... are available in upflow, downflow, horizontal and low-boy configurations for ducted systems. They are also available as floor furnaces, wall furnaces, and free standing space heaters. Oil-fired outdoor furnaces and combination units are rare.... The ducted system, oil-fired, forced air furnaces are usually equipped with pressure-atomizing burners. The pump pressure and the orifice size of the injection nozzle regulate the firing rate of the furnace. Electric ignition is used to ignite the burners.... The combustion chamber and heat exchanger of oil-fired furnaces are normally formed as a common single chamber. It is formed from heavy gage steel into a welded assembly. The hot flue products flow through the inside of the heat exchanger into the chimney. The conditioned air flows over the outside of the heat exchanger and into the air supply plenum.

French

Domaine(s)
  • Fours et chaudières (Chauffage)
CONT

Maison de fin de semaine (...) On peut prévoir aussi le chauffage par air chaud avec générateur à mazout ou à gaz et distributions par gaines.

OBS

Fournaise : Ce terme est considéré comme impropre par les puristes. Selon Dagenais, dans son "Dictionnaire des difficultés de la langue française au Canada", "fournaise" serait un calque de l'anglais "furnace" et nous devrions plutôt dire "chaudière" lorsque le fluide caloporteur est l'eau ou la vapeur et "générateur d'air chaud", lorsque le fluide, est l'air. Cependant, ce terme reste d'usage fréquent au Québec, autant en langue parlée qu'en langue écrite.

Spanish

Save record 18

Record 19 1987-05-04

English

Subject field(s)
  • Aeroindustry
CONT

The [freeze prevention] system is located in the aft accessory compartment and consists of a temperature control(modulating and shut-off) valve, temperature control thermostat, mufflers, and ducts. The ground operated APU is used with the left-hand pack to provide the warm air required to raise the temperature of the heat exchanger cooling air. The system taps into the APU bleed air supply duct before the check valve at the elbow under the catwalk and air is distributed by auxiliary ducts to a muffler under the flow control valve of each pack and to a single spray bar upstream of the left diverter valve. A temperature control valve in the ducting regulates the volume of bleed air to be used.

French

Domaine(s)
  • Constructions aéronautiques
CONT

Ce silencieux est fixé par vis sur la prise d'air du refroidisseur d'huile. Il est constitué d'une cuvette et d'un couvercle percés de plusieurs orifices qui permettent le passage de l'air de refroidissement. L'insonorisation est assurée par de la laine de verre qui est placée à l'intérieur de la cuvette.

OBS

silencieux : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 19

Record 20 1986-08-25

English

Subject field(s)
  • Aeroindustry
CONT

The [freeze prevention] system taps into the APU bleed air supply duct... and air is distributed by auxiliary ducts to a muffler... and to a single spray bar upstream of the left diverter bar.... The portion of the bleed air dispersed by the spray bar in the left connecting elbow mixes with cold ambient air drawn by the left heat exchanger cooling air fan.

OBS

Dispositif du système antigivrage, particulier au DC-9. Il n’est utilisé qu’au sol.

French

Domaine(s)
  • Constructions aéronautiques
OBS

tube injecteur : terme accepté par le Comité d'étude de la terminologie des cartes de travail du DC-9.

Spanish

Save record 20

Record 21 1986-07-02

English

Subject field(s)
  • Engineering
  • Geophysics
  • Geothermal Power Plants
CONT

Hot rock circulating system. If, and when, power can be extracted from artificially fractured rocks by circulating water through the fissures, it will be possible to adjust the rate of circulation so as to match the heat supply to the pattern of demand, at any load factor, without introducing problems of bore instability or of fluid wastage at off-peak times.

French

Domaine(s)
  • Ingénierie
  • Géophysique
  • Centrales géothermiques

Spanish

Save record 21

Record 22 1986-07-02

English

Subject field(s)
  • HVAC Distribution Systems
  • Geophysics
CONT

In Reykjavik, supplementary fuel, storage tanks and overpumping are all used to achieve an economic optimum for the entire heat supply system.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
  • Géophysique

Spanish

Save record 22

Record 23 1986-06-25

English

Subject field(s)
  • Air Conditioning and Heating
  • Geophysics
CONT

Geothermal airconditioning has hitherto been affected by means of small, or fairly small, units for cooling a single building, apartment or perhaps a small complex of buildings. It has been proposed by Einarsson [...] that whole tropical cities could be served by a public cooling network much in the same way, but "in reverse" so to speak, as the Reykjavik district heating system.

OBS

Most of [...](the) air conditioners work on the mechanical compressor system, requiring external work usually supplied by electricity; but some work on the absorption principle which requires a heat supply. Geothermal heat can provide that requirement.

French

Domaine(s)
  • Conditionnement de l'air et chauffage
  • Géophysique

Spanish

Save record 23

Record 24 1985-10-18

English

Subject field(s)
  • Translation
  • Gas and Oil Heating
CONT

There are a number of performance factors that determine how well your heating system is able to supply heat to your home. For all non-electric heating systems there are two basic approaches to defining efficient performance. Both measure the percentage of heat available in a fuel that is actually delivered as heat to the house. Steady state efficiency is a performance factor that is easily measured over a short period of time. It indicates the performance of a system that has been running long enough to allow all furnace components to reach their normal operating temperatures... Seasonal efficiency...

French

Domaine(s)
  • Traduction
  • Chauffage au gaz et au mazout

Spanish

Save record 24

Record 25 1982-08-31

English

Subject field(s)
  • Combustion and Fuels (Fireplaces)
CONT

The essential elements are : the fresh sludge feed system : with or without buffer storage, the drier : with or without heat-resistant masonry, the furnace proper : with pre-heating burners and supplementary burner, the ventilation system : intended to supply air of combustion and used to expand the supporting mass in the case of a fluidized bed, the dust-extracting system :heat recovery system : from the hot gases of combustion(by air of combustion re-heater or by heat recovery boiler).

French

Domaine(s)
  • Combustion et combustibles (Foyers)
CONT

On distinguera essentiellement : le dispositif d'alimentation en boues fraîches, avec ou sans stockage régulateur, le sécheur: avec ou sans maçonnerie réfractaire, le four proprement dit: avec brûleurs de préchauffage et brûleur d'appoint; le système de ventilation: destiné à la fourniture de l'air comburant et également à l'expansion de la masse support dans le cas de lit fluidisé, l'ensemble de dépoussiérage : la récupération de chaleur : sur les gaz chauds de la combustion (par réchauffeur d'air comburant ou par chaudière de récupération). L'évacuation des cendres.

Spanish

Save record 25

Record 26 1982-08-10

English

Subject field(s)
  • HVAC Distribution Systems
OBS

The return-air system shall be designed to handle the entire air supply. Where any part of a return-air duct will be exposed to radiation from the furnace heat exchanger or other heat radiating part within the furnace, parts of return ducts directly above or within 2 ft of the outside furnace casing shall be non-combustible.

French

Domaine(s)
  • Distribution et évacuation (chauffage et conditionnement d'air)
OBS

Les réseaux de reprise d'air doivent être conçus de manière à pouvoir véhiculer la totalité de l'air distribué. Lorsqu'une partie quelconque d'un conduit de reprise d'air est exposée au rayonnement de l'échangeur de chaleur ou de tout autre élément d'un générateur d'air chaud les parties de ce conduit qui se trouvent directement au-dessus de la jaquette extérieure du générateur d'air chaud ou dans un rayon de 2 pi de celle-ci doivent être incombustibles.

Spanish

Save record 26

Record 27 1980-07-15

English

Subject field(s)
  • Air Conditioning and Heating
OBS

because of the high heat generated by electronic equipment, a localized forced air supply system is used to maintain the electronic equipment at an acceptable working temperature.

French

Domaine(s)
  • Conditionnement de l'air et chauffage

Spanish

Save record 27

Record 28 1980-03-06

English

Subject field(s)
  • Nuclear Power Stations
CONT

Emergency Water Supply System. This system is designed to provide an alternative source of water in the unlikely possibility that :-Makeup water to the Heat Transport system or steam generators should fail(...)

OBS

Applies to CANDU nuclear reactors.

French

Domaine(s)
  • Centrales nucléaires
CONT

Système d'alimentation d'urgence en eau. Ce système est prévu pour assurer une autre source d'alimentation en eau au cas peu probable où l'eau d'appoint destinée au système de caloportage ou aux générateurs de vapeur ferait défaut (...)

Spanish

Save record 28

Copyright notice for the TERMIUM Plus® data bank

© Public Services and Procurement Canada, 2026
TERMIUM Plus®, the Government of Canada's terminology and linguistic data bank
A product of the Translation Bureau

Features

GCtranslate (available on the Government of Canada network only)

Use this artificial intelligence prototype to translate Government of Canada content up to and including Protected B. Available to employees of selected departments and agencies only.

Writing tools

The Language Portal’s writing tools have a new look! Easy to consult, they give you access to a wealth of information that will help you write better in English and French.

Glossaries and vocabularies

Access Translation Bureau glossaries and vocabularies.

Date Modified: